Dialysis Center of Westerly
A dialysis facility in Westerly, Rhode Island 02891
One Rhody Drive, Westerly, Rhode Island 02891. (401) 596-0368.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 14, 2026.
- 5of 5 CMS’s star rating
- Not rated patient survey rating
- 3 deficiencies cited in the last three years
- 15 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jun 20, 2024: a standard inspection.
3 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
When those deficiencies happened
3 deficiencies in 1 month of the last 36. Last cited Jun 2024. Most serious: Standard-level. The last 3 years, to Oct 19, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
Jun 20, 2024: standard inspection3 deficiencies
-
Environment: Secure And Restricted
The inspectors’ words, 398 words
“ENVIRONMENT-SECURE & RESTRICTED CFR(s): 494.40(a) 8 Environment: secure & restricted The water purification and storage system should be located in a secure area that is readily accessible to authorized users. The location should be chosen with a view to minimizing the length and complexity of the distribution system. Access to the purification system should be restricted to those individuals responsible for monitoring and maintenance of the system. This Standard is not met as evidenced by: 21613 Based on surveyor observation, and staff interview, it has been determined that the facility failed to ensure that the water purification and storage systems were secure and only accessible to individuals responsible for monitoring and maintenance of the system for 1 of 1 water purification and storage system areas observed. Findings are as follows: During a surveyor interview with the Clinical Manager on 6/17/2024 at 8:35 AM, she revealed that the entry codes for the doors to the treatment and office/employee areas is the same entry code for the water purification and storage system area door. During a surveyor observation on 6/17/2024 at 8:45 AM, revealed one of the doors to access the water purification and storage system area has the same entry code as the door for the waiting room to the dialysis treatment room and the door for the office/employee areas. During a surveyor observation on 6/17/2024 at 11:30 AM, a delivery person, not employed by the facility was seen in the water purification and storage system area. Additionally, one of the doors in the back of the water purification and storage system area was propped open, allowing direct access to the water purification and storage system area from the outside. Further observation failed to reveal evidence any staff were in the area. During a surveyor interview during the above observation, the delivery person revealed a staff member opened the door for him and left him unsupervised. During a surveyor interview immediately following the above observation with the Clinical Manager, on 6/17/2024 at 11:33 AM, she acknowledged that a staff member had left the delivery person unattended in the water purification and storage system area and that the water purification and storage system area should be accessible to authorized users only. Additionally, she was unable to provide evidence that access to the water purification and storage system area was restricted to those individuals responsible for monitoring and maintaining the system.”
-
Pe - Equipment Maintenance - Manufacturer’S Dfu
The inspectors’ words, 650 words
“PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 46539 Based on surveyor observation, record review, and staff interview, it has been determined that the facility failed to ensure that the water purification, storage supply room, the conductivity (the degree to which a specified material conducts electricity) and pH (acidity or alkalinity of a solution) meters were maintained in accordance with the manufacturer’s recommendations for 1 of 1 water purification and storage system areas observed. Additionally, the facility failed to ensure that the dialysis chair’s upholstery was maintained for 4 of 15 chairs observed. Findings are as follows: 1. Surveyor observations made during the flash tour of the water purification and storage areas on 6/17/2023 at approximately 9:00 AM in the presence of the Clinical Manager revealed, the water purification and storage system areas had an accumulation of dust and a white substance on the bicarbonate mixers, carbon tanks, and floor, as well as other equipment and machinery in the room. Additionally, during the above observation, it was revealed that the water purification and storage area had a large amount of white crystallized matter accumulating on the granuflo (dry acid dialysate, use to help to clean the blood of dialysis patients, who accumulate impurities when their kidneys stop filtering effectively) transfer pipes, and on the wall as well as on the floor surrounding it. 2. During a surveyor observation with the Facility Technical Manager (FTM) on 6/18/2024 at approximately 9:30 AM, revealed rust on the baseboard of the heating system (approximately 10 inches in width x 10 feet in length) in the water purification and storage areas. Further observation revealed the flooring in the water purification, storage and supply rooms had cracked floor tires and scuff marks on the walls. During a surveyor observation with the FTM on 6/18/2024 at 10:55 AM, he acknowledged the above observations and revealed that staff should have cleaned the area. The FTM was unable to provide evidence as to when the water purification and storage system areas were last cleaned. During a surveyor interview with the Clinical Manager on 6/18/2024 at 2:45 PM, she acknowledged the walls and flooring in the facility are in need of repair and/or replacement. 3. During a surveyor observation on 6/17/2024 at 8:49 AM, of the water purification and storage system areas, in the presence of the Clinical Manager revealed 4 bottles of “H&S Conductivity Standard Solution [a solution used to calibrate a meter to check water quality]” that expired on 4/18/2024. During a surveyor interview with the Clinical Manager on 6/17/2024 at 8:50 AM, she acknowledged that the above-mentioned solutions had expired and the expired items should be disposed of. 4. During surveyor observations on 6/17/2024 at 10:35 AM and 12:21 PM revealed, the upholstery on the seats of the dialysis chairs at stations 7 and 14 were torn/cracked. During an additional surveyor observation on 6/18/2024 at 9:43 AM revealed the upholstery on the seats of the dialysis chairs at stations 3 and 9, and were also torn/cracked. During a surveyor interview and observation on 6/18/2024 at 9:45 AM with the Clinical Manager, she acknowledged the upholstery on the seats of the dialysis chairs at stations 3, 7, 9, and 14’s were torn/cracked. During a surveyor interview immediately following the above observation, the Clinical Manager indicated that all the chairs in the facility are utilized at this time and that the facility had ordered 2 new chairs in July of 2023. She was unable to provided evidence that additional the above-mention chairs were going to be repaired or replaced or that there was any follow up with manufacturer related to the order placed in July of 2023. 21613”
-
Appropriateness Of Dialysis Rx
The inspectors’ words, 339 words
“PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 21613 46539 Based on surveyor observation, record review, and staff interview it has been determined that the facility failed to ensure that staff follow the dialysis prescription when administering dialysis treatments for 1 of 4 sample patients reviewed, Patient ID #7. Findings are as follows: Record review revealed Patient ID #7 was admitted to the facility in June of 2024 with a diagnosis of renal sclerosis (hardening of the kidney) and is receiving hemodialysis (a procedure where a dialysis machine and a special filter called an artificial kidney are used to clean the patient’s blood three times a week). Review of the patient’s dialysis prescription revealed a dialysate (a fluid that is used in dialysis treatment that is made up of water, electrolytes, and salt) with potassium 2.0 and calcium 2.5 was ordered to be delivered on 6/17/2024. Further record review of the patient’s treatment flowsheet for 6/17/2024 revealed, the patient dialysate treatment was verified by two staff members, including Certified Clinical Hemodialysis Technician, Staff A. During a surveyor observation in the presence of Staff A on 6/17/2024 at 1:45 PM, the patient was observed receiving dialysate with potassium of 3.0 and not the potassium 2.0 that was prescribed for him/her. During a surveyor interview immediately following the above observation with Staff A, she acknowledged that the patient was receiving his/her dialysate with potassium 3.0 instead of 2.0, as ordered. Staff A further indicated that the patient had began receiving his/her treatment at 12:37 PM. During a surveyor interview with the Clinical Manager on 6/17/2024 at 1:57 PM, she indicated that she would expect the staff to follow the prescribed dialysis treatment, as ordered. Additionally, the manager indicated that she would have expected the two staff members that verified the patient’s dialysate treatment prior to initiating the treatment to have identified the error.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jun 20, 2024 | Standard inspection | 3 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Nov 19, 1980.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: American Renal Associates.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and peritoneal dialysis.
- Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
- 15 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the American Renal Associates chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 5 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 5 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 2 dialysis facilities CMS lists in Washington County, 2 have a star rating from CMS: 2 rated 5 of 5.
- CMS rates this one 5 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Wakefield Dialysis Center | 5 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 19, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 19, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 14, 2026 and checked Oct 19, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 19, 2026.