Fmc of Juana Diaz
A dialysis facility in Juana Diaz, Puerto Rico 00795
Parque Industrial Amuela, Carr. 584 Km 0.4, Juana Diaz, Puerto Rico 00795. (787) 837-8303.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 2of 5 CMS’s star rating
- 4of 5 patient survey rating
- 8 deficiencies cited in the last three years
- 20 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on May 14, 2025: a standard inspection.
8 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
8 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
May 14, 2025: standard inspection8 deficiencies
-
Ic - Sanitary Environment
The inspectors’ words, 405 words
“IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 47632 Based on observations made in the treatment area on 05/13/2025, it was determined that the facility failed to monitor the environment to ensure its sanitation and reduce the potential transmission of infectious agents within and between units, due to the lack of adherence to “standard precautions”, expired medications and medical surgical supplies. Findings include: 1. During the observations made in the medication room area with Supervisor (employee #1) and Charge Nurse (employee #5) on 05/13/2025, the following were found: a. On 05/13/2025 at 9:44 AM, two bottles of clonidine 0.1 milligrams (mg) of 100 tablets were observed without signature or date. b. On 05/13/2025 at 9:49 AM, two vials of Solucortef 100 mg in 2 milliliters (ml) expired on 04/2025 were found in the emergency kit. c. On 05/13/2025 at 9:50 AM, two monofilament foot screen tests observed expired 04/2025. d. On 05/13/2025 at 9:56 AM, two bottles of sublingual nitroglycerin 0.4 of 100 tablets were observed to be expired on 01/2025. e. On 05/13/2025 at 9:59 AM, three vials of heparin 30,000 units in 30 ml were observed expired on 03/2025. f. On 05/14/2025 at11:42 AM, it was noted that a 100-unit vial of Humalog insulin had expired on 01/28/2025. g. On 05/14/2025 at 11:48 AM, one box of Prevnar 13 expired 12/2024 was observed. 51629 2. During observation and inspection of the room currently used for patient training in the modalities of Home Hemodialysis (HH) and Continuous cyclic peritoneal dialysis (CCPD) on 05/13/2025 at 10:00 AM, the following sterile supplies (medical surgical material) were found expired: a. Two Stay - safe - catheter extension set with expiration dates of April 30, 2025. b. One Peritoneal Dialysis Accessory with expiration date of December 25, 2023. 51829 3. On 05/13/2025 at 9:26 AM during the review of the medical-surgical equipment at Station #1, the following was identified: a. The supply of medical-surgical material known as recirculatory, total quantity 42 units, with expiration date of 03/31/2025. 4. On 05/13/2025 at 10:00 AM during the review of the crash cart, the following was identified: a. One NSS 0.9% 500 ml with expiration date of 02/2025. b. Two suction tubes with expiration date of 07/2024.”
-
Ic - Items Taken To Station Disposed/Dedicated Or Disinfected
The inspectors’ words, 217 words
“IC-IF TO STATION=DISP/DEDICATE OR DISINFECT CFR(s): 494.30(a)(1)(i) Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient. -- Nondisposable items that cannot be cleaned and disinfected (e.g., adhesive tape, cloth covered blood pressure cuffs) should be dedicated for use only on a single patient. -- Unused medications (including multiple dose vials containing diluents) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients. This Standard is not met as evidenced by: 47632 Based on observation made in the treatment area on 05/13/2025 at 10:05 AM, it is determined that the facility failed to maintain the dialysis station clean and disinfected of items placed on top or side of the treatment chair for 9 out of 9 observations at station #3, #5, #6, #9, #16, #17, #19, #20 and #21, Findings include: During observation of the treatment area, station #3, #5, #6, #9, #16, #17, #19, #20 and #21, patients were observed having personal belongings either hanging from or on top of the folding table of the treatment chairs.”
-
Pe - Safe, Functional, Comfortable Environment
The inspectors’ words, 116 words
“PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 47384 Based on the observational tour of the facility treatment area on 05/13/2025, it was determined that the facility failed to maintain the building in which dialysis services are furnished to ensure the safety of the patients, the staff and the public. Findings include: The facility failed to maintain emergency disconnection kit on every chair where a patient is receiving treatment or orientation. One kit was missing on chairs #4, #5, #19 and two kits missing on chair #20.”
-
Pe - Building - Constructed/Maintained To Ensure Safety
The inspectors’ words, 187 words
“PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 47384 Based on the observational tour of the facility on 05/13/2025, it was determined that the facility failed to observe that the building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. Findings include: 1. During the visual observation of the parking area, 4 handicapped parking spaces were observed in front of the unit. This 4 parking’s do not comply with the requirements of at least 96 inches wide and did not have an access aisle of at least 60 inches wide as required by the American Disability Act (ADA). 2. During a visual inspection of the parking area, it was observed that the route from the parking lot via the ramp to the entrance of the unit had excessive gravel and dirt, making it difficult for people in wheelchairs or walkers to move around.”
-
Pe - Equipment Maintenance - Manufacturer’S Dfu
The inspectors’ words, 113 words
“PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 47384 Based on observation made in the treatment area on 05/13/2025 at approximately 8:45 AM, it is determined that the facility failed to maintain a program to ensure that all equipment is maintained and operated in accordance with the manufacturer’s recommendations. Findings include: Nine (9) out of twenty (20) dialysis machines were observed with peeled paint on the platform where dialysate gallons are placed.”
-
Pe - Patient Care Environment - Sufficient Space
The inspectors’ words, 128 words
“PE-PT CARE ENVIRONMENT-SUFFICIENT SPACE CFR(s): 494.60(c)(1) The space for treating each patient must be sufficient to provide needed care and services, prevent cross-contamination, and to accommodate medical emergency equipment and staff. This Standard is not met as evidenced by: 47384 Based on observation made in the treatment area on 05/13/2025 at approximately 8:45 AM, it is determined that the facility failed to comply with sufficient space to provide needed care and services, prevent cross-contamination, and to accommodate medical emergency equipment and staff. Findings include: During visual observation of clinical treatment area it was observed that stations #9 and #11 did not comply with the required minimum of 36 inches on both sides of the station in order to accommodate medical emergency equipment and staff in a medical emergency.”
-
Pe - Hemodialysis Patients In View During Treatments
The inspectors’ words, 224 words
“PE-HD PTS IN VIEW DURING TREATMENTS CFR(s): 494.60(c)(4) Patients must be in view of staff during hemodialysis treatment to ensure patient safety, (video surveillance will not meet this requirement). This Standard is not met as evidenced by: 47632 Based on observations made in the treatment area on 05/13/2025, it was determined that the facility failed to ensure that patients receive treatment in a manner that allows staff to have full view of patients access site for the first and second shift at patients’ stations #7, #19, and #21. This deficient effect 3 out of 22 stations patients observed receiving treatment. Findings include: During the observations made in the treatment area on 05/13/2025 at 10:05 AM, the following were found: 1. On 05/13/2025 at 10:05 AM, the patient was located on station # 5, it was observed that the vascular access was covered with sheets. 2. On 05/13/2025 at 10:08 AM, the patient was located on station # 17; it was observed that the vascular access was covered with sheets. 3. On 04/14/2025 at 10:12 AM, the patient was located on station # 21, it was observed that the vascular access was covered with sheets. The facility failed to ensure vascular access sites should be seen by staff members during all dialysis treatment. Allowing patients to cover access provides an opportunity for accidents of needle.”
-
Manage Volume Status
The inspectors’ words, 816 words
“POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 47632 Based on nineteen records reviewed (RR), review of policies and procedures and interview with Clinical Manager (employee #6), it was determined that the facility failed to follow established procedures after identifying patients’ high blood pressure (BP) or low blood pressure (BP) during dialysis treatment for 3 out of 19 records reviewed (RR #2, #4, and #6). Findings include: Upon review of the facility’s policy Title: Hypertension last update on 09/07/2021, Version: 1, Policy clearly stated on the procedures that during hemodialysis treatment personnel will recognized, report and immediately address diastolic blood pressures greater than 100-millimeter mercury (mm/Hg), Page:1. During the flowsheet review performed on 05/13/2025 and 05/14/2025 at 9:00 AM to 3:00 PM the following were found: 1. RR# 2 is a 67-year-old female admitted to the facility on 04/26/2022 with a diagnostic End Stage Renal Disease. During the record review performed on 05/13/2025 at 3:29 PM, the hemodialysis treatment three times a week for four hours, Dialyzer 180 NRE Optiflux, Blood Flow Rate (BFR) of 400, Dialysis Flow Rate (DFR) of 700 and Patient Dry Weight (EDW) of 74 kilograms (kg). a. On 05/06/2025 at 5:50 PM, pre dialysis treatment revealed that the Blood Pressure (BP) was 209/60 mg/Hg, at 5:58 PM, it was revealed that the BP was 209/60 mg/Hg, at 6:14 PM, it was revealed that the BP was 229/69 mg/Hg, at 6:34 PM, it was revealed that the BP was 199/86 mg/Hg, at 7:34 PM, it was revealed that the BP was 182/75 mg/Hg, at 8:07 PM, it was revealed that the BP was 186/79 mg/Hg, at 8:34 PM, it was revealed that the BP was 213/84mg/Hg, at 9:09 PM, it was revealed that the BP was 200/84 mg/Hg, at 9: 35 PM, it was revealed that the BP was 193/74 mg/Hg, at 9:57 PM it was revealed that the BP was 191/74 mg/Hg and post dialysis treatment revealed that the BP was 192/74 mg/Hg. No evidence was found of nursing interventions, documentation for hypertension or notification of the physician. 2. RR# 4 is a 52-year-old male admitted to the facility on 11/01/2024 with a diagnostic End Stage Renal Disease. During the record review performed on 05/14/2025 at 10:00 AM, the hemodialysis treatment three times a week for four hours and fifteen minutes, Dialyzer 180 NRE Optiflux, Blood Flow Rate (BFR) of 425, Dialysis Flow Rate (DFR) of 800 and Patient Dry Weight (EDW) of 102.5 kilograms (kg). a. On 04/25/2025 at 6:04 PM, it was revealed that the BP was 172/107 mg/HG, at 6:34 PM, it was revealed that the BP was 167/101 mg/hg, at 7:02 PM, it was revealed that the BP 173/105 mg/Hg, and at 9:02 PM, it was revealed that the BP was 164/102 mg/Hg. b. On 05/05/2025 at 6:04 PM, it was revealed that the BP was 167/101 mg/Hg, at 6:34 PM, it was revealed that the BP was 169/105 mg/Hg, and at 7:04 PM, it was revealed that the BP was 177/106 mg/Hg. c. On 05/07/2025 at 8:09 PM, It was revealed that the BP was 182/89 mg/Hg, at 9:41 PM, it was revealed that the BP 183/102 mg/Hg, and at 10:06 PM, it was revealed that the BP was 184/104 mg/Hg. d. On 05/09/2025 at 6:33 PM, it was revealed that the BP was 175/100 mg/Hg and at 8:45 PM, it was revealed that the BP was 186/99 mg/Hg. No evidence was found of nursing interventions, documentation for hypertension or notification of the physician. 3. RR# 6 is a 52-year-old male admitted to the facility on 03/16/2022 with a diagnostic End Stage Renal Disease. During the record review performed on 05/13/2025 at 2:17 PM, the hemodialysis treatment three times a week for four hours, Dialyzer 180 NRE Optiflux, Blood Flow Rate (BFR) of 300, Dialysis Flow Rate (DFR) of 600 and Patient Dry Weight (EDW) of 78.5 kilograms (kg). a. On 04/30/2025 at 6:34 PM, it was revealed that the BP 202/80 mg/HG, at 7:07 PM, it was revealed that the bp was 215/82 mg/Hg, at 7:39 PM, it was revealed that the BP was 219/81 mg/Hg, at 8:0 PM, it was revealed that the BP was 200/84 mg/Hg, and at 8:44 PM, it was revealed that the BP was 185/69 mg/Hg. b. 05/05/2025 at 7:06 PM, it was revealed that the BP was 188/85 mg/Hg, at 7:41 PM, it was revealed that the BP was 190/85 mg/Hg, at 8:08 PM, it was revealed that the BP was 190/57 mg/Hg, and at 8:23 PM, it was revealed that the BP was 190/57 mg/Hg. No evidence was found of nursing interventions, documentation for hypertension or notification of the physician.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| May 14, 2025 | Standard inspection | 8 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Sep 30, 2015.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 20 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
- In CMS’s survey, patients rate its staff 4 of 5.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- Patients rate it 4 of 5 in CMS’s survey of in-center hemodialysis patients (96 interviews, Oct 18, 2024 to Jul 11, 2025): 85% rated the facility 9 or 10 out of 10.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 2 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | 4 of 5 |
How does it compare nearby?
- No other dialysis facility CMS lists is in Juana Diaz.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.