Hearth Record

Davita Concord Township Dialysis

A dialysis facility in Chadds Ford, Pennsylvania 19317

265 Wilmington West Chester Pike, Chadds Ford, Pennsylvania 19317. (610) 558-6965.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 14, 2026.

The last 24 months 1 deficiency in 1 month of the last 36. Last cited Dec 2023. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Dec 14, 2023: a standard inspection.

1 deficiency cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

When those deficiencies happened

1 deficiency in 1 month of the last 36. Last cited Dec 2023. Most serious: Standard-level. The last 3 years, to Oct 19, 2026.

1 deficiency by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

Dec 14, 2023: standard inspection1 deficiency
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 467 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 37972 Based on review of facility policy, observation (OBS) of treatments performed, and an interview with the Facility Administrator, the facility did not ensure that patient care staff removed gloves, performed hand hygiene, and donned clean gloves during central venous catheter (CVC) exit site care for one (1) of two (2) OBS (OBS #3), and during discontinuation of dialysis with an AV fistula for one (1) of two (2) OBS (OBS #11). Findings include: A review of facility policy on December 14, 2023, at approximately 2:00 P.M. revealed the following: Policy # 1-05-01 titled “Infection Control for Dialysis Facilities” stated, “Hand Hygiene: 1. All teammates, Physicians and Non-Physicians (NPP) will perform hand hygiene: ... b. prior to gloving and immediately after removal of gloves,... d. after patient and dialysis delivery system contact,... g. before touching clean areas such as supplies, supply cart and chairside keyboard/mouse.” Policy # 1-04-02B titled “Central Venous Catheter (CVC) With Clearguard HD Antimicrobial End Caps Procedure” stated, “Procedure: 1. Perform had hygiene per procedure. Put on PPE (personal protective equipment)... 4. Remove old dressing and discard... 7. Remove gloves and discard. Perform hand hygiene per procedure and re-glove. 8. Holding catheter with the non-dominant hand and using aseptic technique, clean exit site... 9. Clean each CVC limb/cap... 10. Remove gloves and discard, perform hand hygiene per procedure and re-glove... 12. Place sterile 2x2 gauze over catheter exit site... 14. Remove gloves and discard, perform hand hygiene per procedure and re-glove...” Observation of the treatment area was conducted on December 13, 2023, from approximately 10:00 A.M. to 12:30 P.M. and December 14, 2023, from approximately 9:30 A.M. to 10:45 A.M. revealed the following: OBS #3, Station #2, on December 13, 2023, at approximately 11:20 A.M., during initiation of dialysis with a CVC and CVC exit site care, EMP #3 (employee) was observed initiating dialysis with a CVC. After treatment was initiated, EMP #3 did not perform hand hygiene or don new gloves before or during performance of CVC exit site care as required by facility policy. OBS #11, Station #4, on December 14, 2023, at approximately 9:46 A.M., during discontinuation of dialysis with an AV fistula/graft, EMP #3 was observed performing hand hygiene and donning gloves, disconnecting the dialysis lines, touching the dialysis machine, preparing strips of tape, removing the fistula needles, and applying dressings to the needle sites without changing gloves and performing hand hygiene throughout the procedure as required by facility policy. An interview with the Facility Administrator on December 14, 2023, at approximately 4:15 P.M. confirmed the above findings.”

    Rule V0113. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Dec 14, 2023Standard inspection1 deficiency cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Sep 20, 2017.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 5 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, better than expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 55 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 11 dialysis facilities CMS lists in Delaware County, 10 have a star rating from CMS: 1 rated 5 of 5, 6 rated 4 of 5, 1 rated 3 of 5, 2 rated 2 of 5.
  • CMS rates this one 5 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 19, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.