Dci Shenango Valley
A dialysis facility in Hermitage, Pennsylvania 16148
737 Brookshire Drive, Hermitage, Pennsylvania 16148. (724) 342-3040.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 1of 5 CMS’s star rating
- Not rated patient survey rating
- 4 deficiencies cited in the last three years
- 17 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Nov 17, 2023: a standard inspection.
4 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 1 month of the last 36. Last cited Nov 2023. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Nov 17, 2023: standard inspection4 deficiencies
-
Ic - Wear Gowns, Shields/Masks; Staff Not Eat/Drink In Tx Area
The inspectors’ words, 310 words
“IC-GOWNS, SHIELDS/MASKS-NO STAFF EAT/DRINK CFR(s): 494.30(a)(1)(i) Staff members should wear gowns, face shields, eye wear, or masks to protect themselves and prevent soiling of clothing when performing procedures during which spurting or spattering of blood might occur (e.g., during initiation and termination of dialysis, cleaning of dialyzers, and centrifugation of blood). Staff members should not eat, drink, or smoke in the dialysis treatment area or in the laboratory. This Standard is not met as evidenced by: 31759 Based on review of facility policy, observation, and staff (EMP) interview, the facility failed to ensure staff wore a mask when performing procedures during which spurting or spattering of blood might occur for one (1) of two (2) observations of initiation of dialysis with and arteriovenous fistula (OBS# 4.1). Findings included: Review of facility policy on November 16, 2023, at 10:45 a.m. showed: “PROCEDURE NO: 301 ... Universal Precautions ... Facial Protection - Face shields provide protection for the eyes, nose and mouth. All areas of the face should be covered by whichever method is chosen. 39. Facial coverings may be either full facial shields or a mask used in conjunction with goggles.” “PROCEDURE NO: 104 ... CANNULATION OF ESTABLISHED ARTERIOVENOUS FISTULA (AVF) ... PROCEDURE ... 1. ... Put on PPE ... 9. Perform cannulation.” “PROCEDURE NO: 310 ... General Facility Infection Control ... POLICY: ... Staff members should wear gowns, face shields, eye wear, or mask to protect themselves and prevent soiling of clothing when performing procedures during which spurting or spattering of blood might occur.” Observation (OBS#4.1) of initiation of dialysis with an AVF on November 15, 2023, at 8:50 a.m. revealed EMP10 (patient care technician) insert needles into patient’s arm and initiate dialysis but EMP10 only wore protective eyewear and no mask to cover his/her nose and mouth. Interview with EMP10 and EMP9 (charge nurse) after the observation confirmed findings.”
-
Ic - Items Taken To Station Disposed/Dedicated Or Disinfected
The inspectors’ words, 396 words
“IC-IF TO STATION=DISP/DEDICATE OR DISINFECT CFR(s): 494.30(a)(1)(i) Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient. -- Nondisposable items that cannot be cleaned and disinfected (e.g., adhesive tape, cloth covered blood pressure cuffs) should be dedicated for use only on a single patient. -- Unused medications (including multiple dose vials containing diluents) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients. This Standard is not met as evidenced by: 31759 Based on review of facility policy, manufacturer’s directions for use, observation, and staff (EMP) interview, the facility failed to ensure single use items were dedicated or disposed of for 17 of 17 patients with arteriovenous fistulas (AVF) who required the use of a tourniquet (AVF1-17). Findings included: Review of facility policy on November 16, 2023, at 10:45 a.m. showed, “PROCEDURE NO: 310 ... General Facility Infection Control ... POLICY: ... 5. Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient.” Observation of a supply cart designated for clean supplies during a treatment day on November 15, 2023, a 2 p.m. revealed many orange tourniquets piled onto and hanging from the cart. Interview with EMP12 (patient care technician) and EMP14 (nurse educator) at time of observation confirmed findings. EMP12 described the facility’s process for handling the tourniquets: the tourniquets are supplied in bulk (one large bag containing quantity of 250) from a local hospital, the tourniquets are used on patients with arteriovenous fistulas during initiation of dialysis, and once dialysis is completed, the tourniquets are placed into a large container of disinfectant where they dwell for 20 minutes. The tourniquets are then placed on the supply cart for use on the next day’s patients. Review of the manufacturer’s directions for use for tourniquets used by the facility was conducted on November 16, 2023, at 10:25 a.m. with EMP2 (clinic manager). The review showed, “Tourniquets (Non-Latex) ... Single patient use [not designed to be disinfected and reused].” Retrieved from https://www.halyardhealth.com/wp-content/uploads/MediChoice-Supplier-Diversity-Catalog.pdf”
-
Ic - Aseptic Techniques For Iv Meds
The inspectors’ words, 225 words
“IC-ASEPTIC TECHNIQUES FOR IV MEDS CFR(s): 494.30(b)(2) [The facility must-] (2) Ensure that clinical staff demonstrate compliance with current aseptic techniques when dispensing and administering intravenous medications from vials and ampules; and This Standard is not met as evidenced by: 31759 Based on review of facility policy, observation, directions for use, and staff (EMP) interview, the facility failed to ensure one (1) of one (1) medication vial of Tubersol (TB1) was discarded after opening per facility policy and manufacturer’s directions for use. Findings included: Review of facility policy on November 16, 2023, at 11 a.m. showed, “PROCEDURE NO 1115 ... Disposal of Medication Vials ... When a multi-dose vial has been opened, ... the vial should be dated, initialed, and discarded within 30 days, unless manufacturer specifies a shorter date. Refer to package insert.” A flash tour was conducted on November 14, 2023, at 8:45 a.m. with EMP2 (clinic manager). Observation of facility’s medication fridge revealed an open vial of Tubersol medication (TB1). The vial was opened and used on 10/4/2023. Interview with EMP2 at time of observation confirmed findings and that the medication was last used on 11/13/2023. Review of the medication vial’s package insert on November 14, 2023, at 9 a.m. showed, “Tubersol ... STORAGE ... A vial of Tubersol which has been entered and in use or 30 days should be discarded.””
-
Pe - Equipment Maintenance - Manufacturer’S Dfu
The inspectors’ words, 319 words
“PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 31759 Based on review of facility policy, manufacturer’s directions for use, logs, and staff (EMP) interview, the facility failed to ensure two (2) of two (2) pHoenix meters (P01710K & P13565) were operated in accordance with manufacturer’s directions for use. Findings included: Review of facility policy and procedure on November 16, 2023, at 11:05 a.m. showed, “Phoenix Meter Disinfection, Calibration, Use and Storage PURPOSE: To assure the pHoenix Meter is properly ... calibrated ... prior to use. To assure that the dialysis machine’s conductivity, pH and temperature are accurate when compared to an independent meter. ... 2. The meter will be verified against 14.0 mS conductivity and 7.0 pH standard solutions daily prior to use, ... Conductivity should read 14 mS +/- .1; pH should read 7 +/- .1. The meter will be recalibrated when the conductivity or pH are out of range.” Review of manufacturer’s directions for use for facility’s pHoenix meters on November 16, 2023, at 11:15 a.m. showed, “Test Instrument User’s Guide For the ... pHoenix Meter ... MesaLabs ... Rev. L ... Test Instrument User’s Guide ... Checking instrument calibration ... Verify accurate calibration of the conductivity and pH functions before use.” A review of “DAILY PHOENIX METER LOG[s]” was conducted on November 14, 2023, at 1 p.m. The review showed that P01710K was out of range on 9/27/2023 with a conductivity of 13.8 (acceptable range 14.1-13.9) and no recalibration. P13565 was out of range on 8/25, and 10/4/2023 with a conductivity of 13.8 on both days with no recalibration. Interview with EMP6 (area technical manager) on November 14, 2023, at 1:42 p.m. confirmed above findings.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Nov 17, 2023 | Standard inspection | 4 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Oct 26, 1998.
- Run as a non-profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Dialysis Clinic, Inc.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and peritoneal dialysis.
- Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
- 17 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Dialysis Clinic, Inc. chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 1 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 3 dialysis facilities CMS lists in Mercer County, 3 have a star rating from CMS: 1 rated 4 of 5, 2 rated 1 of 5.
- CMS rates this one 1 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Fkc Hermitage | 4 |
| Dci Grove City | 1 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.