Davita Dunkirk Dialysis
A dialysis facility in Dunkirk, New York 14048
3958 Vineyard Dr, Dunkirk, New York 14048. (716) 366-1931.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 6 deficiencies cited in the last three years
- 14 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Dec 4, 2025: a standard inspection.
6 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
6 deficiencies in 1 month of the last 36. Last cited Dec 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Dec 4, 2025: standard inspection6 deficiencies
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 515 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 40430 Based on policy review, observation, and interview, nursing staff do not follow standard infection control practices regarding the use of gloves and hand hygiene. Findings include: Review of the policy “Infection Control for Dialysis Facilities,” revised April 2023, indicated all teammates will perform hand hygiene prior to gloving and immediately after the removal of gloves, after patient and dialysis delivery system contact, and before touching clean areas such as supplies, supply cart, and chairside keyboard/mouse. Review of the policy “Medication Policy,” revised October 2023, indicated all teammates administering medications must utilize aseptic (practices to prevent spread of infection) technique. An aseptic environment and aseptic technique are used when preparing medications. Careful attention to proper handwashing is performed at this time. Observation on 12/02/25 from 12:35 PM to 12:55 PM in the patient care area revealed the following: -At 12:35 PM, Staff (L), Registered Nurse, wore gloves to prepare and label medications at the medication counter/prep area. Without removing their gloves, Staff (L) exited the medication prep area to deliver oral medications to Station #4 for Patient #9. Without removing gloves, Staff (L) returned to the medication prep area, retrieved medication from the medication fridge and opened a drawer to retrieve a syringe. Staff (L) removed their gloves but did not perform hand hygiene and exited the unit to the supply storage area. -At 12:45 PM, Staff (L), entered Station #1 for Patient #11. Without performing hand hygiene, Staff (L) applied clean gloves and administered medications intravenously (IV-into the vein) through the hemodialysis machine. Staff (L)removed their gloves and exited the station without performing hand hygiene. Staff (L) returned to the medication prep area, did not perform hand hygiene, and applied a new pair of gloves before delivering/administering IV medication to Station #6 for Patient #10. Staff (L) removed their gloves, but did not perform hand hygiene before touching the computer keyboard to document in the electronic medical record. -At 12:55 PM, Staff (L) was preparing to discontinue treatment for Patient #10 at Station #6. Without removing their gloves, Staff (L) exited Station #6 and entered the nursing station area, across from Station #7 & #8, to move a medication infusion pump/pole that they stated needed to be disinfected “when they were done with Patient #10.” Staff (L) returned to Station #6, removed/changed their gloves but did not perform hand hygiene. Staff (L) discontinued (returned blood) Patient #10’s treatment, removed their gloves, but did not perform hand hygiene before applying a new pair of clean gloves to remove Patient #10 needles and hold gauze on the needle insertion sites until bleeding stopped. Staff (L) then removed gloves but did not perform hand hygiene and applied a new pair of clean gloves to tape gauze to the needle insertion sites. Interview on 12/04/25 at 10:45 AM with Staff (B), Registered Nurse, verified these findings.”
-
Ic - Wear Gowns, Shields/Masks; Staff Not Eat/Drink In Tx Area
The inspectors’ words, 434 words
“IC-GOWNS, SHIELDS/MASKS-NO STAFF EAT/DRINK CFR(s): 494.30(a)(1)(i) Staff members should wear gowns, face shields, eye wear, or masks to protect themselves and prevent soiling of clothing when performing procedures during which spurting or spattering of blood might occur (e.g., during initiation and termination of dialysis, cleaning of dialyzers, and centrifugation of blood). Staff members should not eat, drink, or smoke in the dialysis treatment area or in the laboratory. This Standard is not met as evidenced by: 40430 Based on policy review, observation, and interview, the facility failed to ensure personal protective equipment (PPE-equipment worn for protection from workplace hazards such as blood) such as gowns, face shields, eye wear, or masks were worn properly when performing procedures during which spurting or splattering of blood may occur. Findings include: Review of the policy “Personnel Protective Equipment,” dated August 2006, indicated teammates will wear PPE including, but not limited to full face shields or mask and goggles. Review of the policy “Infection Control For Dialysis Facilities,” April 2023, indicated appropriate PPE (i.e., gown, gloves, eye protection, face shield) will be worn whenever there is the potential for contact with body fluids. Disposable gloves will be worn when caring for the patient or touching the patient’s equipment at the dialysis station. Observation on 12/02/25 at 12:40 PM, at the lab supply/processing counter/area revealed Staff (L), Registered Nurse, without wearing gloves, removed two blood filled lab specimen tubes from the centrifuge (device used to separate the contents of blood in blood tubes for diagnostic tests) and placed them in the laboratory refrigerator. Staff (L), then placed two blood filled tubes into the centrifuge without wearing gloves. At 01:00 PM at Station #6 for Patient #10, Staff (L) discontinued treatment for Patient #10. Staff (L) removed their gloves and packed up Patient #10 personal belongings. Staff (L) reset a machine alarm two times without wearing gloves. Observation on 12/03/25 at 09:55 AM at Station #9 for Patient #8 revealed Staff (M), Patient Care Technician, cannulated (inserted needles) Patient #8’s fistula (surgically created access for dialysis) and initiated dialysis treatment. Staff (M) was wearing eye protection/goggles, but their surgical mask was below their nose with their nostrils exposed. At 10:20 AM at Station #11 for Patient #15 and at 02:36 PM at Station #8 for Patient #16 Staff (M) discontinued Patient #15 and Patient #16 treatment, removed their needles, and held the needle sites until the bleeding stopped. Staff (M) was wearing eye protection/goggles, but their surgical mask was below their nose with their nostrils exposed. Interview on 12/04/25 at 10:45 AM with Staff (B), Registered Nurse, verified the findings.”
-
Ic - Items Taken To Station Disposed/Dedicated Or Disinfected
The inspectors’ words, 256 words
“IC-IF TO STATION=DISP/DEDICATE OR DISINFECT CFR(s): 494.30(a)(1)(i) Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient. -- Nondisposable items that cannot be cleaned and disinfected (e.g., adhesive tape, cloth covered blood pressure cuffs) should be dedicated for use only on a single patient. -- Unused medications (including multiple dose vials containing diluents) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients. This Standard is not met as evidenced by: 25545 Based on observation and interview, for four of 14 hemodialysis machines observed, the facility did not ensure that all hemodialysis machines on the treatment floor are cleaned and disinfected between patients (hemodialysis machine #4, #8, #11, and #16). Findings include: Observation on 12/03/25 at 01:20 PM on the treatment floor revealed hemodialysis machines #4, #8, #11 and #16 had medical tape on the fold-down keyboard, and the fold-down touch pad. The medical tape was not changed between patient treatments, and it is not a fluid resistant material that is capable of being decontaminated. Staff (K), Registered Nurse, stated the tape on the hemodialysis machines is to hold the lower piece of the keyboard to the upper piece (of the hemodialysis machine). Interview on 12/04/25 at 10:00 AM with Staff (E), Biomedical Staff, verified these findings.”
-
Pe - Safe, Functional, Comfortable Environment
The inspectors’ words, 185 words
“PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 25545 Based on observation, document review, and interview, the facility does not ensure there is hot water at 12 of 12 sink faucets and there is not tepid water at one of one eye wash stations on the treatment floor. Findings include: Observation on 12/02/25 at 11:15 AM on the treatment floor revealed 12 of 12 sink faucets had a temperature of 58.1 degrees Fahrenheit from the hot water. The eyewash had a temperature of 58.1 degrees Fahrenheit. The “Facilities Guidelines Institute- 2018 edition,” requires a minimum temperature of 105 degrees Fahrenheit for faucets at sinks and requires eye wash stations to be tepid with a minimum of 60 degrees Fahrenheit. Review of the work order document number “WEB-681939,” revealed an entry dated 09/18/25 that indicated “...there’s no hot water on the treatment floor.” Interview on 12/03/25 at 1:15 PM with Staff (E), Biomedical Staff, verified these findings.”
-
Pe - Equipment Maintenance - Manufacturer’S Dfu
The inspectors’ words, 295 words
“PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 40430 Based on policy review, observation, document review, and interview, the facility does not maintain equipment according to the manufacturer instructions Specifically, the facility does not ensure expired supplies are not available for use. Findings include: Review of the policy “Obtaining Patient Lab Specimens,” revised October 2025, indicated teammates are to verify the expiration date on all laboratory specimen tubes. Expired laboratory specimen tubes are not to be used and are to be discarded. Review of the policy “Blood Glucose Testing,” revised April 2025, indicated the monitor and test strips are stored and used according to monitor manufacturer instructions. Expired control solutions and test strips are not used. Observation on 12/02/25 at 11:00 AM in the nursing station and lab supply area/cupboards revealed one bottle of “Glucose Meter Test Strips (used to test blood sugar levels)” were opened but not labeled with “opened on” date. The “notice” printed on the side of the bottle indicated the test strips expire four months after opening; one “control solution one” bottle and one control solution two (solutions used to check if glucose meter is working accurately)” bottle were not labeled with “opened on” date. The “notice” printed on the side of the bottle indicated the control solutions expire three months after opening; 13 dark blue/navy top blood tubes (used for laboratory tests) expired on 04/01/25; and eight light blue top blood tubes expired on 10/31/25. Interview on 12/03/25 at 09:30 AM with Staff (H), Registered Nurse, verified these findings.”
-
Appropriateness Of Dialysis Rx
The inspectors’ words, 255 words
“PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 40430 Based on policy review, medical record review, and interview, for one of six medical records reviewed, nursing staff did not ensure the hemodialysis prescription was implemented and/or maintained as ordered by the physician. Specifically, the duration of treatment/time, dialysate flow rate (DFR- the rate solution used during dialysis to clean blood and maintain electrolyte/mineral balance in the body), and blood flow rate (BFR- the rate blood is processed during dialysis) were not implemented/maintained as ordered (Patient #20). Findings include: Review of the policy “Pre-Intra-Post Treatment Data Collection, Monitoring and Nursing Assessment,” April 2024, indicated if the dialysis prescription is not being met (including dialysis flow rate or change to/inability to obtain prescribed blood flow rate), the reason will be documented, and the licensed nurse will be informed. Review of the medical record flowsheets for Patient #20, dated 11/11/25 to 12/02/25, revealed a physician order for 210-minute (3.5 hours) duration/treatment time, a BFR of 400 milliliters per minute (ml/min), and DFR of 600ml/min. The BFR and DFR were not implemented/maintained as ordered on 11/14/25. The treatment time was not implemented as ordered on 12/02/25. There was no documentation in the medical record to indicate why the BFR, DFR and/or time were not implemented as ordered. Interview on 12/04/25 at 10:45 AM with Staff (B), Registered Nurse, verified the findings.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Dec 4, 2025 | Standard inspection | 6 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Sep 19, 2018.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 14 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 2 dialysis facilities CMS lists in Chautauqua County, 2 have a star rating from CMS: 2 rated 3 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Davita Jamestown Dialysis Center | 3 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.