Davita Niagara Dialysis Center
A dialysis facility in Niagara Falls, New York 14304
2932 Military Road, Niagara Falls, New York 14304. (716) 297-4059.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 5 deficiencies cited in the last three years
- 13 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on May 9, 2024: a standard inspection.
5 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
5 deficiencies in 1 month of the last 36. Last cited May 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
May 9, 2024: standard inspection5 deficiencies
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 446 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 40430 Based on policy review, observation, and interview, staff do not follow standard infection control practices regarding the use of gloves and hand hygiene. Failure to follow standard infection control practices places patients and staff at risk for a potential infection. Findings include: Review on 05/07/24 of the policy “Infection Control for Dialysis Facilities,” last revised April 2023 indicated that all teammates will perform hand hygiene prior to gloving and immediately after removal of gloves, after contamination with blood or other infectious material, and before touching clean areas such as supplies. Review on 05/07/24 of the policy “Central Venous Catheter (CVC) with Clearguard HD Antimicrobial End Caps Procedure,” last revised October 2023 indicated that staff are to remove gloves, perform hand hygiene and re-glove after removing the old dressing, prior to cleaning the CVC exit site. Observation on 05/07/24 at 01:45 PM at Station #6 revealed Staff (K), Patient Care Technician was discontinuing treatment for Patient #21. Staff (K) grabbed the sharps container (container for contaminated supplies/needles on wheels), with their clean gloved hand, to move it closer. Staff (K) proceeded to handle clean gauze pads to remove Patient #21’s fistula (access used for dialysis) needles and hold pressure to the needle insertion sites. Staff (K) did not remove gloves, perform hand hygiene, and apply new gloves after touching the sharp’s container. Observation on 05/08/24 at 10:30 AM, at Station #12 revealed Staff (I), Registered Nurse was completing catheter exit site care for Patient #16. Staff (I) removed the old dressings covering the catheter exit site and ports, but did not change gloves, perform hand hygiene, and apply clean gloves prior to continuing with catheter care. Staff (I) proceeded to place a clean gauze pad under the catheter ports. Staff (I) reached for the sharp’s container, grabbed the handle with their gloved hand to move it closer, and continued with catheter care. Staff (I) did change gloves, perform hand hygiene, and/or apply clean gloves after touching the sharp’s container. Observation on 05/08/24 at 11:10 AM at Station #8 revealed Staff (I), Registered Nurse, was completing catheter exit site care (site where the catheter enters the body) for Patient #18. Staff (I) removed the old dressings covering the catheter exit site and ports, but did not change gloves, perform hand hygiene, and apply clean gloves prior to continuing with catheter care. Interview on 05/09/24 at 01:15 PM with Staff (F), Facility Administrator, verified these findings.”
-
Ic - Staff Education Re Catheters/Catheter Care
The inspectors’ words, 359 words
“IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 40430 Based on policy review, observation, and interview, nursing staff did not standard aseptic technique while performing central venous catheter (catheter-access used for dialysis) care. This has the potential for exposing patients and staff to infections. Findings include: Review on 05/07/24 of the policy “Central Venous Catheter (CVC) with Clearguard HD Antimicrobial End Caps Procedure,” last revised October 2023 indicated that upon completion of dialysis, staff are to discard the existing barrier and place a new, clean moisture proof barrier under the catheter to prevent contamination, prior to aseptically disconnecting the blood lines from the catheter ports. Observation on 05/07/24 at 01:40 PM at Station #5 for Patient #19 and at 01:50 PM at Station #11 for Patient #5 revealed Staff (B), Nurse Manager discontinued treatment via catheter for both patients. Staff (B) did not place a clean, moisture proof barrier under the catheter ports while disconnecting the blood lines from the catheter ports. Observation on 05/08/24 at 09:35 AM at Station #9 revealed Staff (G), Licensed Practical Nurse discontinuing treatment via catheter for Patient #23. Staff (G) did not place a clean, moisture proof barrier under the catheter ports while disconnecting the blood lines from the catheter ports. Interview on 05/09/24 at 01:15 PM with Staff (F), Facility Administrator, verified these findings.”
-
Pe - Building - Constructed/Maintained To Ensure Safety
The inspectors’ words, 245 words
“PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 42572 Based on observation and interview, the building is not maintained, free from defects and/or hazards, to ensure safety and functionality for patients, staff, and visitors. Findings include: Observation on 05/07/24 at 10:45 AM in the water room revealed there was water leaking from the threaded plumbing fittings on both sides of the deionization filter. There was an approximately one square foot puddle on the floor below the leak. Observation on 05/07/24 at 01:30 PM in information technology room on the second floor revealed a two-inch round penetration in the floor with cables running through it without a fire stop sealing system (prevent the spread of fire and smoke) in place. Observation on 05/07/24 at 02:00 PM in the elevator machine room on the second floor revealed that above the drop ceiling, there was a four-inch sprinkler line, two-inch sprinkler line, and a two-inch by four-inch hole, creating penetrations in the two-hour fire barrier wall without a fire stop sealing system in place. Observation on 05/07/24 at 02:05 PM on the second floor revealed a 90-minute fire rated door to the elevator machine room that did not have an automatic closing device installed. Interview on 05/07/24 at 02:15 PM with Staff (E), Biomed Technician, verified these findings.”
-
Appropriateness Of Dialysis Rx
The inspectors’ words, 197 words
“PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 40430 Based on policy review, medical record review, and interview, the facility does not ensure that blood flow rates are maintained per physician order for one of five patients (Patient #1). Failure to maintain the ordered blood flow rate has the potential for an inadequate hemodialysis treatment and/or a delay in identifying an issue with the access. Findings include: Review on 05/08/24 of the policy “Pre-Intra-Post Treatment Data Collection, Monitoring and Nursing Assessment,” revised April 2024 indicated that if the dialysis prescription is not being met, including dialysis blood flow rate, the reason will be documented. Review on 05/08/24 of the treatment flow sheets for Patient #1 from 04/13/24 to 05/07/24 revealed the prescribed blood flow rate of 400 ml/minute was not maintained on 04/25/24 and 04/27/24. There was no documentation in the medical record to indicate why the blood flow rate was not maintained as prescribed. Interview on 05/09/24 at 01:15 PM with Staff (F), Facility Administrator, verified these findings.”
-
Mr - Complete Records Promptly
The inspectors’ words, 219 words
“MR-COMPLETE RECORDS PROMPTLY CFR(s): 494.170(b)(1) (1) Current medical records and those of discharged patients must be completed promptly. This Standard is not met as evidenced by: 40430 Based on medical record review, policy review, and interview, the facility does not ensure orders are promptly placed in the medical record for 1 of 5 patients. (Patient #2). This practice can lead to an inadequate dialysis prescription for patients and an adverse patient outcome. Findings include: Review on 05/08/24 of the policy “Non-Physician Practitioner (NPP) Order Policy,” revised April 2024 indicated verbal orders may only be taken by a licensed nurse teammate authorized to accept physician/provider verbal orders. All orders must be entered into the electronic health record. Review on 05/08/24 of the medical record for Patient #2 revealed the following: -On 04/23/24, the provider ordered the bicarbonate to be changed from 38 to 32. -On 04/25/24 and 04/27/24 (two of seven treatments), staff documented the bicarbonate as 38.). -Medical record review found no documentation to indicate why the bicarbonate was not at the prescribed setting. Interview on 05/09/24 at 10:15 AM with Staff (I), Registered Nurse, revealed the provider was in to see Patient #2 during dialysis on 04/23/24 and changed the bicarbonate order for treatment. Interview on 05/09/24 at 01:15 PM with Staff (F), Facility Administrator, verified these findings.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| May 9, 2024 | Standard inspection | 5 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jan 29, 2015.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
- Doesn’t offer a shift starting at 5 p.m. or later.
- 13 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 4 dialysis facilities CMS lists in Niagara County, 4 have a star rating from CMS: 1 rated 4 of 5, 2 rated 3 of 5, 1 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Fresenius Kidney Care - Wheatfield | 3 |
| Davita Niagara Falls Kidney Center | 2 |
| Davita Lock City Dialysis | 4 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.