Hearth Record

Rogosin West Side Dialysis

A dialysis facility in New York, New York 10019

619 West 54th Street 4th Floor, New York, New York 10019. (646) 317-0402.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 5 deficiencies in 2 months of the last 36. Last cited Nov 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Nov 6, 2024: a standard inspection.

5 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

5 deficiencies in 2 months of the last 36. Last cited Nov 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

5 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Nov 6, 2024: standard inspection2 deficiencies
  • Emergency Lighting

    The inspectors’ words, 152 words

    “Emergency Lighting CFR(s): NFPA 101 Emergency Lighting Emergency lighting of at least 1-1/2 hour duration is provided automatically in accordance with 7.9. 20.2.9.1, 21.2.9.1, 7.9 This Standard is not met as evidenced by: 36207 Based on document reviews, and staff interviews, the facility did not maintain, inspect, and test emergency lighting of at in accordance with NFPA 101, 2012 edition. Failure to maintain emergency lighting systems could negatively impact evacuation during emergency. Findings Include, During the document review on 11/06/2024 at 1:30 p.m., it was noted in the facility’s “Emergency Light Log” for 2022, 2023 and 2024 that the facility did not conduct annual 1-1/2 hours functional testing for the emergency light systems. An interview with staff C (Biomed Equipment Technician) on 11/06/24 at 1:45 PM, confirmed this finding. The above finding was brought to the attention of Staff A, Facility administrator during the onsite exit conference on 11/06/2024 at 2:45 PM.”

    Rule K0291. Standard-level.

  • Maintenance, Inspection And Testing - Doors

    The inspectors’ words, 233 words

    “Maintenance, Inspection & Testing - Doors CFR(s): This Standard is not met as evidenced by: 36207 Based on observations, document reviews, and staff interviews, the facility did not maintain, inspect, and test fire-rated door assemblies, according to the NFPA 80, 2010 edition. Failure to maintain Fire doors could negatively impact the closing of fire doors in case of fire. Findings Include, During the facility tour on 11/06/2024 between 10:30 a.m. and 11:30 p.m., 1) it was noted that the 90-minute fire rated 2-leaf doors between the main waiting area and elevator corridor, when closed the clearance between both leaves was more than 1/8”. According to NFPA 80, Section 6.3.1.7.1 - Swinging Doors with Builders Hardware, the allowable clearance for meeting edges for a pair of doors is 1/8”. 2) A 45- minutes fire rated door for water room in the dialysis center did not have a fire rating label at the time of survey. During the document review on 11/06/2024 at 1:30 p.m., it was noted that there were no written inspection records for Testing of the fire door assembly available for review. An interview with staff C (Biomed Equipment Technician) on 11/06/24 at 1:45 PM, confirmed this finding. He further stated that he was not aware of the requirement. The above finding was brought to the attention of Staff A, Facility administrator during the onsite exit conference on 11/06/2024 at 2:45 PM.”

    Rule K0761. Standard-level.

Jun 7, 2024: standard inspection3 deficiencies
  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 316 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 22676 Based on observation, interview, facility policy review and review of Centers for Disease Control (CDC) guidance, the facility failed to ensure that the wall boxes (dispensing outlets) at dialysis stations five of 28 was cleaned and the buildup of yellow substance removed. This deficient practice had the potential to cause bacteria to grow in the wall boxes and cause harm by infecting the 125 patients receiving in-center hemodialysis at the facility. Findings included: Observation of the wall boxes on 06/05/24 2:25 PM, Stations 1-5 revealed a dark yellow sediment with white sediment build-up on the wall boxes. During an interview on 06/06/24 at 10:30 AM the Biomed stated that he/she did not know when the wall boxes were to be cleaned. He/She confirmed that boxes One- Five were visibly dirty with a dark yellow build up. Review of the facility policy titled, “Disinfection of Wall Boxes,” dated 01/28/20, indicated, “Disinfect wall box with disinfectant wipes.” Review of the “CDC Dialysis Safety,” located on the CDC website at www.cds.gov titled, “Wall boxes and Drains” indicated, “All box surfaces should be disinfected at least daily (e.g., at the end of the day after all patients have dialyzed); cleaning and disinfection might be needed more frequently (e.g., when visibly dirty). Cleaning and disinfection of the wall box should be performed after the patient has left the station, and not during patient care activities... More than one disinfectant wipe or application may be needed to ensure all wall box surfaces are visibly wet with disinfectant to achieve contact time specified by the manufacturer.””

    Rule V0122. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 424 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 18750 Based on observation, interview, and review of the facility’s policies, the facility failed to ensure three of four oxygen concentrators had the dust filter covering the air intake area of the casing. This deficient practice had the potential to allow debris to enter the oxygen concentrator and could affect the patients breathing. Findings include: Review of the facility policy titled, “Preventive Maintenance Schedules for Equipment,” revised 02/25/20 revealed, “Purpose: To ensure that the dialysis machines and all other ancillary equipment are kept in good working condition and are operating properly. Policy. . . 5. All miscellaneous equipment will receive a preventive maintenance at least twice an annually (e.g. scale, EKG machine, O2 concentrator) . . .” During tour of the facility on 06/05/24 at 10:40 AM, Patient (P)13 was located at Station 12. P13 was wearing a nasal canula attached to a concentrator that had no filter covering the air intake area which the air is taken into the machine to create oxygen. Also, during the tour two concentrators were noticed to be at the other end of the treatment room floor with no filters covering the air intake area. During an observation on 06/06/24 at 12:25 PM, P13 located at Station 2 was placed on a concentrator without a filter covering the grid. During an interview on 06/06/24 at 12:30 PM, the Nurse Manager (NM) was shown the concentrator and asked if it should have a filter cover the air intake area. The NM stated, “Yes. There should be a black sponge-like filter covering the area.” We went back to look at the other concentrators that were bagged and ready for use. The two concentrators did not have filters either. The NM stated they should all have filters.” The NM was asked who makes sure there are filters on the concentrators and that they are lean and ready to go. The NM stated Biomed should make sure the filters are on the machines. During an interview on 06/06/24 at 12:40 PM, the Biomed was asked about the concentrators and the missing filters. The Biomed stated, “There should be a dust filter on the concentrator covering the grid where the air goes into the machine. This will keep debris from getting into the machine.””

    Rule V0403. Standard-level.

  • Pe - Hemodialysis Patients In View During Treatments

    The inspectors’ words, 303 words

    “PE-HD PTS IN VIEW DURING TREATMENTS CFR(s): 494.60(c)(4) Patients must be in view of staff during hemodialysis treatment to ensure patient safety, (video surveillance will not meet this requirement). This Standard is not met as evidenced by: 22676 Based on observation, interview, and review of the policy, the facility failed to ensure patients the hemodialysis access sites were uncovered and visible for one of three days of the survey. The patient and the access site (faces, needle insertion sites and line connections) must always be visible to staff during treatment, to ensure the lines and needles do not become dislodged or disconnected. Excessive blood loss can result from needle dislodgement, resulting in dire consequences such as severe hypotension, hospitalization, blood transfusions, and death, and could affect all 125 in-center hemodialysis patients receiving care at the facility. Findings include: During a tour on the treatment floor with the Nurse Manager on 06/05/24 at 10:56 AM Patient (P) 12 at Station 7, was observed with a blanket covering his/her Central Venous Catheter (CVC) lines. Certified Clinical Hemodialysis Technician (CCHT) 1 was observed walking by the patient and he/she did not have the patient uncover his/her access. An interview with CCHT1 on 06/05/24 at 11:00 AM, confirmed that he/she was assigned to P12, and he/she did not have the patient to uncover his/her access. CCHT1 stated that he/she was not aware of the CVC lines and connection needed to be uncovered. An interview with the Nurse Manager on 06/05/2024 at 11:00 AM confirmed that P12’s access and lines were covered by a blanket and the staff failed to ask the patient to uncover the access. Review of the facility’s policy titled, “Treatment Monitoring” revision date February 1, 2000, indicated, “The vascular access status and line connections and access site to remain visible at all times ...””

    Rule V0407. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Nov 6, 2024Standard inspection2 deficiencies cited
Jun 7, 2024Standard inspection3 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Aug 26, 2014.
  • Run as a non-profit.
  • No deficiency on record in the last three years.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 28 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 4 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • CMS lists it as independent, not owned or managed by a chain.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 5 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, better than expected; patients on a kidney transplant waitlist, better than expected.
  • Patients rate it 5 of 5 in CMS’s survey of in-center hemodialysis patients (58 interviews, Oct 18, 2024 to Jul 11, 2025): 84% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 55 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 55 of 5

How does it compare nearby?

  • Of the 20 dialysis facilities CMS lists in New York County, 19 have a star rating from CMS: 5 rated 5 of 5, 5 rated 4 of 5, 5 rated 3 of 5, 1 rated 2 of 5, 3 rated 1 of 5.
  • CMS rates this one 5 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.