Trinitas Medical Arts Building - Dialysis
A dialysis facility in Elizabeth, New Jersey 07202
200 Williamson St Ste 210, Medical Arts Building, Elizabeth, New Jersey 07202. (908) 994-7011.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 4 deficiencies cited in the last three years
- 19 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jul 26, 2024: a standard inspection.
4 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 1 month of the last 36. Last cited Jul 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jul 26, 2024: standard inspection4 deficiencies
-
Ic - Sanitary Environment
The inspectors’ words, 256 words
“IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 48966 Based on one of two observation of cleaning the dialysis station, staff interviews, and review of facility policy, it was determined that the facility failed to provide and maintain a sanitary environment to minimize the transmission of infectious agents within and between the hemodialysis station. Findings include: On 7/24/24 at 10:23 AM, Staff (S) 7, a Registered Nurse, was observed cleaning hemodialysis Station #2. The red sharps container and red medical waste container were touching the privacy curtain between Station #1 and Station #2. The privacy curtain had a reddish brown stained area approximately 3 inches in diameter. During an interview at 10:35 AM, S4, the Hospital Nurse Manager, confirmed the privacy curtain between Station #1 and #2 had a visible stained area present. During an interview at 10:56 AM, S8, the Nurse Manager, stated the Nurse Manager and Charge Nurse do weekly environmental rounds. If something is observed that needs attention housekeeping is called to address the issue. Housekeeping is responsible for changing the soiled curtains. A review of the facility policy titled, “Infection Control for Dialysis Facilities,” reviewed in 2/23, stated, “... Staff/Patient Safety 18. All procedures involving blood or other body fluids will be performed in a manner to minimize splashing, spraying, spattering or generation of droplets ...” N.J.A.C. 8:43A-24.8(d)”
-
Dialysate Proportioning - Monitor Ph/Conductivity
The inspectors’ words, 468 words
“DIALYS PROPORT-MONITOR PH/CONDUCTIVITY CFR(s): 494.40(a) 5.6 Dialysate proportioning: monitor pH/conductivity It is necessary for the operator to follow the manufacturer’s instructions regarding dialysate conductivity and to measure approximate pH with an independent method before starting the treatment of the next patient. This Standard is not met as evidenced by: 48966 Based on one of two observations of the pHoenix Meter XL (hand-held meter for measuring conductivity, temperature, and pH of solutions) calibration stations, staff interviews, and review of manufacturers direction for use, it was determined the facility failed to ensure the Reverse Osmosis (RO) water and bleach solution bottle are properly labeled. Findings include: During an observation on 7/22/24 at 12:14 PM, the pHoenix meter calibration station at Clean Sink #2, across from Station #6, lacked a dated, initialed, and timed label on the RO water and bleach solution bottles. The manufacturer’s instructions on the RO water bottle specified “to empty this bottle daily and refill it with fresh RO water. Wash with a disinfectant soap or diluted soap.” The manufacturer’s instructions on the bleach solution bottle specified “mix one part household bleach and 99 parts RO water, empty, rinse, and refill this container daily.” During an interview at 12:16 PM, Staff (S) 6, the Charge Nurse, confirmed the bottles were not labeled and was uncertain when the bottles contents were last changed. During an interview at 12:23 PM, S5, a Patient Care Technician (PCT), confirmed the RO and bleach bottles should be labeled. S5 stated the PCT in the morning is responsible to change the RO water and bleach daily and label the bottles with the date, time, and initials. S5 was unsure when the bottles were last changed. During an interview on 7/24/24 at 10:27 AM, S9, the Biomed Technician, confirmed the RO and bleach bottles should be labeled with the date, time, and initials and the contents changed daily. S9 stated the PCT who opens in the morning is responsible to change the contents and label the bottles. A review of the manufacturer’s instructions for use of the pHoenix Meter XL stated, “... It is recommended that treated water (RO, DI, or Distilled water) be the only choice for rinsing meters. Disinfecting Recommendations - Measurement Module and Syringe. If disinfection of the meter is required (other than those meters in storage), we recommend that you follow these steps daily before the first use of the meter: 1. Draw 1% bleach solution (one-part bleach to ninety-nine parts dialysis quality water) mixed fresh daily, into the meter to the 10 mL [milliliter] line. Seal the Measurement Module with an Air-Tight Luer Cap. 2. Let the solution sit in the meter for approximately ten minutes. After the dwell time expel the bleach solution. 3. Rinse thoroughly by rapidly flushing at least three times with dialysis quality water ...””
-
Achieve Adequate Clearance
The inspectors’ words, 742 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 48966 Based on staff interview, medical record reviews, and review of policies and procedures, it was determined that the facility failed to ensure that hemodialysis treatments were provided in accordance with the hemodialysis prescription for seven of seven patient medical records reviewed (Patient (P) 1, 2, 3, 4, 5, 6 and 7). Findings include: A review of P1’s medical record revealed the following: An initial patient plan of care, dated and signed by the patient and the interdisciplinary care team on 4/24/24, indicated there were no concerns with P1 meeting their adequacy goal. The hemodialysis orders dated 7/1, 7/8, 7/10, 7/12, 7/15, 7/17, and 7/19/24, stated, “... Dialysis Flow Rate (DFR): 800 ...” The “Hemodialysis Record” for the corresponding order dates lacked evidence of the DFR utilized throughout the treatment. A review of P3’s medical record revealed the following: A patient plan of care, dated and signed by the patient and the interdisciplinary care team on 2/27/24, indicated there were no concerns with P3 meeting their adequacy goal. The hemodialysis orders dated 7/2, 7/4, 7/6, 7/11, 7/13, 7/16, 7/18, an 7/20/24, stated “...Dialysis Flow Rate (DFR): 800 ...” The “Hemodialysis Record” for the corresponding order dates lacked evidence of the DFR utilized throughout the treatment. 49828 A review of P2’s medical record revealed the following: A patient plan of care, dated and signed by the patient and the interdisciplinary care team on 2/15/24, indicated there were no concerns with P2 meeting their adequacy goal. The hemodialysis orders dated 7/2, 7/9, and 7/16/24, stated, “ ...DFR: 800 ...” The “Hemodialysis Record” for the corresponding dates lacked evidence of the DFR utilized throughout the treatment. A review of P4’s medical record revealed the following: A patient plan of care, dated and signed by the patient and the interdisciplinary care team on 2/21/24, indicated there were no concerns with P4 meeting their adequacy goal. The hemodialysis orders dated 7/1, 7/3, 7/5, 7/8, 7/10, 7/12, 7/15, 7/17, and 7/19/24, stated, “ ...DFR: 800 ...” The “Hemodialysis Record” for the corresponding dates lacked evidence of the DFR utilized throughout the treatment. A review of P5’s medical record revealed the following: A patient plan of care, dated and signed by the patient and the interdisciplinary care team on 2/28/24, indicated there were no concerns with P5 meeting their adequacy goal. The hemodialysis orders dated 7/1, 7/3, 7/5, and 7/8/24, stated, “ ...Dialysis Flow Rate (DFR): 800 ...” The “Hemodialysis Record” for the corresponding dates lacked evidence of the DFR utilized throughout the treatment. 37656 A review of P6’s medical record revealed the following: A patient plan of care, dated and signed by the patient and the interdisciplinary care team on 2/27/24, indicated there were no concerns with P6 meeting their adequacy goal. The hemodialysis orders, dated 7/1, 7/3, 7/5, 7/8, 7/10, 7/12, 7/15, 7/17, and 7/19/24, stated, “...Dialysis Flow Rate (DFR): 800 ...” The “Hemodialysis Record” for the corresponding dates lacked evidence of the DFR utilized throughout the treatment. A review of P7’s medical record revealed the following: An initial patient plan of care, dated and signed by the patient and the interdisciplinary care team on 2/19/24, indicated there were no concerns with P7 meeting their adequacy goal. The hemodialysis orders, dated 7/1, 7/3, 7/5, 7/8, 7/10, 7/12, 7/15, and 7/17/24, stated, “... Dialysis Flow Rate (DFR): 800 ...” The “Hemodialysis Record” for the corresponding dates lacked evidence of the DFR utilized throughout the treatment. During an interview on 7/24/24 at 1:14 PM, Staff (S) 8, the Nurse Manager, stated that all patients are prescribed a standard 800 DFR and the staff is aware of this. S8 stated the staff would put a note if there was a deviation from the prescribed 800 DFR but do not document the DFR on the hemodialysis treatment record. A review of the facility policy titled, “Assessment of Hemodialysis Patient,” reviewed in 2/23, stated, “... Monitoring of the patient during the hemodialysis treatment should include but not be limited to: ... Monitoring of dialysis machine parameters which include venous pressure, ultrafiltration rate, ultrafiltration goal, dialysis time, dialysate temperature, dialysate conductivity, blood flow, and dialysate flow rate ...” N.J.A.C. 8:43A-24.4(a)”
-
Md Resp - Develop, Review& Approve P&P
The inspectors’ words, 286 words
“MD RESP-DEVELOP, REVIEW & APPROVE P&P CFR(s): 494.150(c)(1) The medical director must- (1) Participate in the development, periodic review and approval of a “patient care policies and procedures manual” for the facility; This Standard is not met as evidenced by: 37656 Based on observation, staff interviews, and a review of facility policy and procedure, it was determined that the facility Medical Director failed to develop a policy and procedure for medication preparation and administration. Findings include: On 7/22/24 at 11:08 AM, during tour of the Treatment Floor, Staff (S) 7, a Registered Nurse, was observed attaching patient medication labels onto four syringes containing clear solutions at the nurse’s station on Side A. Upon interview at the time of observation, S7 stated that he/she prepared the four syringes containing Heparin in the medication room located on Side B but he/she forgot to print the patient labels, so he/she printed the labels at the nurse’s station and was labeling the four syringes. S7, when asked how do you know that you have the right patient and the right dose, S7 stated, “I know my patient’s Heparin dosages.” After labeling the syringes, S7 walked to Station #5 and went back to the Nurse’s Station and discarded all the syringes in the sharps container. On 7/22/24 at 1:00 PM, the policy and procedure for medication preparation and administration was requested from S1, Director of Quality. A policy for Medication Management in the Renal Unit and Medication Use Process were provided but did not include a policy and procedure for medication preparation and administration by the Registered Nurse (RN). On 7/24/24, S1, Nurse Manager confirmed there was no policy and procedure for medication preparation and administration by the RN. N.J.A.C. 8:43A-9.3(a)”
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jul 26, 2024 | Standard inspection | 4 deficiencies cited |
| Jul 26, 2024 | Standard inspection | No deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Oct 22, 2002.
- Run as a non-profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 19 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- CMS lists it as independent, not owned or managed by a chain.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 14 dialysis facilities CMS lists in Union County, 14 have a star rating from CMS: 3 rated 5 of 5, 3 rated 4 of 5, 5 rated 3 of 5, 2 rated 2 of 5, 1 rated 1 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.