Hearth Record

Davita Matawan Dialysis

A dialysis facility in Matawan, New Jersey 07747

764 Highway 34, Ste A, Matawan, New Jersey 07747. (732) 583-1085.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on May 29, 2025: a standard inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

May 29, 2025: standard inspection6 deficiencies
  • Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts

    The inspectors’ words, 407 words

    “IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 39223 Based on three of four observations of clean sink areas, staff interview, and review of facility documents, it was determined that the facility failed to ensure that clean supplies are not stored in designated clean areas next to sinks where splashing and possible cross contamination may occur. Findings include: On 05/27/25 at 11:05 AM, during a tour of the In-Center Treatment Floor, the following was revealed: Three oxygen concentrators were observed to be stored adjacent to the clean sink, designated for handwashing, located across from Station 13. At 11:12 AM, Staff (S)6 (Patient Care Technician) approached the clean sink located across from Station 13 and proceeded to wash his/her hands with soap and water. This created the potential for cross contamination due to splashing during the handwashing process. At 11:14 AM, one wheelchair was observed next to the clean sink, designated for handwashing, located across from Station 10. At 11:15 AM, two oxygen concentrators were observed next to the clean sink, designated for handwashing, located across from Station 4. During an interview at 11:20 AM, S6 stated that the oxygen concentrators were cleaned and disinfected before being stored in the area next to the clean sinks across from Station 4 and Station 13. S6 confirmed that the areas next to the clean sinks were considered designated clean areas. Review of facility policy, titled “Infection Control for Dialysis,” revised April 2023, stated, “ ... FACILITY HYGIENE ... 19. ... a. Clean supplies or equipment will not be placed adjacent to a sink unless a splash guard is in place. ... “ N.J.A.C. 8:43A-24.4(b)”

    Rule V0117. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 593 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 48966 Based on three of three observations of the cleaning and disinfection of a dialysis station, staff interviews, and review of facility documents, it was determined that the facility failed to ensure all surfaces and equipment in the patient station are cleaned and disinfected before preparing the hemodialysis machine for a new patient. Findings include: On 05/27/25 at 10:04 AM, in Station 5, the hemodialysis machine was set up with new dialysis lines for the next patient. Staff (S)4 (Patient Care Technician [PCT]), was observed using a bleach soaked cloth to wipe the dialysis chair, side tables, television, and chase wall but did not wipe the wall box. S4 did not wait until the dialysis station was clean and disinfected before setting up for the next patient to prevent cross contamination. During an interview at 10:06 AM, S4, stated that the dialysis station should be completely clean and disinfected before setting up the hemodialysis machine for a new patient. S4 discarded the dialysis lines on the machine. S4 was not sure if the wall box needed to be cleaned between patients. S4 stated, “the wall boxes are cleaned by the cleaning staff each night.” On 05/27/25 at 10:32 AM, in Station 17, S6 (PCT), was observed cleaning and disinfecting the station. S6 used bleach soaked cloths to wipe all surfaces of the hemodialysis machine but did not empty and wipe the prime bucket. S6 then wiped all surfaces of the patient recliner chair, side tables, and the television but did not wipe the chase wall and wall box. S6 proceeded to bring clean supplies to the dialysis machine for the next patient. During an interview at 10:44 AM, S6 confirmed that the prime bucket was not emptied or wiped and that the chase wall and wall box was not wiped with a bleach soaked cloth. S6 stated that he/she should have not brought the clean supplies to the hemodialysis machine because the prime bucked was not emptied or cleaned. 51227 On 05/27/25 at 10:35 AM, Staff (S)11 (Charge Nurse) used bleach-soaked cloths to clean and disinfect Station 10. S11 wiped the hemodialysis machine and patient recliner chair. S11 did not clean the chase wall or wall box in Station 10. During an interview at 10:40 AM, S11 stated, he/she should have cleaned the chase wall and water box after patient use. Facility policy titled, “Infection Control for Dialysis Facilities,” revised April 2023, stated, “ ... Disinfection ... 13. At the end of each treatment, the dialysis station will be cleaned and disinfected a. Surfaces to disinfect include but are not necessarily limited to: all surfaces in contact with the patient or their belongings (e.g., dialysis chair, tray tables, blood pressure cuff) and frequently contacted by healthcare personnel e.g., control panel; top, front, and sides of dialysis machine; touchscreens; countertops). i. The Wall box, Drain and Water supply lines are considered part of the dialysis delivery system ... ii. Priming containers are to be emptied prior to disinfection ... b. ... Dialysis station must be completely vacated by the previous patient before teammates can begin to bring disinfection supplies to the station, clean or disinfect the station and set up for the next patient ... “ N.J.A.C. 8:43A-24.8(b)”

    Rule V0122. Standard-level.

  • Ic - Staff Education Re Catheters/Catheter Care

    The inspectors’ words, 622 words

    “IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 48966 Based on observation of one of one initiation of hemodialysis using a Central Venous Catheter (CVC, a type of access used for hemodialysis), staff interview and review of facility documents, it was determined that the facility failed to ensure that the initiation of dialysis using a CVC is performed aseptically in accordance with facility policy and procedure. Findings include: On 05/27/25 at 11:40 AM, in Station 14, Staff (S)5 (Registered Nurse [RN]), was observed initiating the hemodialysis treatment to Patient (P)12 through a right chest Central Venous Catheter (CVC). S5 placed multiple clean gloves, two 10 ml (milliliter) syringes, two 10 ml pre-filled saline syringes, and eight to 10 alcohol pads on the clean, disposable pad on the recliner table. After changing the CVC dressing, S5 removed the arterial (red) cap from the CVC and wiped the sides, threads and end of hub for 30 seconds with an alcohol prep pad. S5 connected an empty 10 ml syringe and aspirated approximately five mls of blood into the syringe. S5 removed the syringe from the arterial limb, and placed it onto the clean, disposable pad, next to the pile of clean gloves, potentially contaminating the clean supplies. S5 then flushed with the normal saline syringe before he/she proceeded to remove the venous (blue) cap from the CVC. S5 wiped the sides, threads and end of hub for 30 seconds with an alcohol prep pad and connected an empty 10 ml syringe. S5 aspirated approximately five mls of blood, removed the syringe from the venous limb, and placed it onto the clean, disposable pad, next to the pile of clean gloves, potentially contaminating the clean supplies. S5 then flushed with the normal saline syringe. This was not in accordance with facility policy and procedure. During an interview at 12:31 PM, S5 stated that he/she should not place the blood filled syringes onto the disposable pad next to the clean supplies. S5 stated he/she should dispose of the blood filled syringes in a sharps container. S5’s personnel file was reviewed and indicated the “In-Center Annual Procedural Skills Verification Checklist” which included CVC Care was signed and completed on 8/14/24. Facility policy titled, “Central Venous Catheter (CVC) With Clearguard HD Antimicrobial End Caps Procedure,” Revised April 2025, stated, “ ... Procedure ... 2. ... Set up clean field with all appropriate supplies on a clean, moisture proof barrier. ... Rationale ... 2. ... Verifying that you have all appropriate supplies prior to initiation procedure minimizes opportunities for cross contamination ... 17. Attach sterile 10 ml syringes to the arterial and venous limbs. 18. Open the catheter clamps. Aspirate an amount greater than the catheter limb lumen, generally about 5 ml from each limb. ... 21. Aseptically discard syringe containing indwelling solution from arterial limb and attach a saline filled syringe. Repeat step for venous limb ... “ N.J.A.C. 8:43A-24.8(b)”

    Rule V0147. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 437 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 51227 Based on medical record review, staff interview, and a review of facility documents, it was determined that the facility failed to ensure that the physician ordered blood flow rate (BFR) is met or the reason it could not be met, is documented for three of the nine treatment sheets reviewed for Medical Record (MR)6. Findings include: A review of MR6 revealed a plan of care meeting, dated 05/08/25, that stated, “ ... Area of Focus BP [Blood Pressure] and Fluid Management ... Goal Achieve BP Control as specified by the patient’s physician ... “ Further review of MR6 revealed the following: A physician’s order for hemodialysis treatments three days per week, with a blood flow rate of 400 was started on 03/09/25. The “Treatment Details Report,” dated 03/15/25, documented a BFR of 350 from 6:33 AM, when hemodialysis treatment started, until 10:04 AM, three hours and 30 minutes later, when treatment ended. The “Treatment Details Report,” dated 04/03/25, documented a BFR of 350 from 6:28 AM, when hemodialysis treatment started, until 10:05 AM, three hours and 30 minutes later, when treatment ended. A physician’s order for hemodialysis treatments three days per week with a BFR of 400 was started on 04/09/25. The “Treatment Details Report,” dated 05/13/25, documented a BFR of 350 from 10:11 AM, when hemodialysis treatment started, until 12:21 PM, two hours and 10 minutes later, when treatment ended. This was not in accordance with physician orders. There was no documented evidence of the reason why the ordered BFR was not met, or that the physician was notified of the change. During an interview on 05/29/25 at 9:45 AM, Staff (S)11 (Charge Nurse) stated the reason for BFR changes should be documented by the Registered Nurse and confirmed the treatment sheets lacked documented evidence of the change in BFR. Facility policy titled, “Pre-Intra-Post Treatment Data Collection, Monitoring and Nursing Assessment,” revised April 2024, stated, “ ... 3. Patient identity, prescription and machine settings are verified by teammate prior to initiation of treatment with the exception of blood flow rate which is verified and documented when the ordered rate is obtained after onset of treatment. The prescription components are confirmed by a licensed nurse within one (1) hour of treatment initiation. Prescription components include but are not necessarily limited to: ... f. Blood flow rate ... “ N.J.A.C. 8:43A-8.4(a)”

    Rule V0543. Standard-level.

  • Vascular Access - Monitor/Referrals

    The inspectors’ words, 493 words

    “POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 48966 Based on one of two observations of the initiation of hemodialysis through an arteriovenous fistula (AVF, a type of vascular access used for hemodialysis), staff interview, and review of facility documents, it was determined that the facility failed to ensure that staff clean and disinfect the patient’s vascular access site prior to initiating hemodialysis treatment in accordance with the facility policy. Findings include: On 05/27/25, at 11:10 AM, in Station 10, Staff (S)4 (Patient Care Technician [PCT]) was observed removing the plastic wrap from the left arm fistula (AVF) and wiping off the topical numbing cream with a 2x2 gauze. S4 did not clean the AVF with a cleansing agent. S4 proceeded to cleansed the arterial (first) site of the AVF with an alcohol pad in a circular motion then wiped with one Betadine pad for two seconds and let the site dry for one minute before cannulating (the act of inserting a needle). This was 28 seconds less than the 30 seconds required by facility policy and one minute less for the drying time required by facility policy. S4 proceeded to cleanse the venous (second) site of the AVF with an alcohol pad in a circular motion then wiped with one Betadine pad for six seconds and let the site dry for one minute before cannulating. This was 24 seconds less than the 30 seconds required by facility policy and one minute less for the drying time required by facility policy. During an interview at 11:21 AM, S4 stated the AVF needed to be cleaned with soap and water or another type cleansing agent. S4 also stated that when using Betadine you need to clean for 20 seconds and let it dry for five seconds before cannulating the AVF. S4’s personnel file was reviewed and indicated the “In-Center Annual Procedural Skills Verification Checklist” which included AVF/AVG Cannulation was signed and completed on 8/14/24. Facility policy titled, “AV Fistula Or Graft Cannulation With Nipro Or Medisystems Safety Fistula Needles (SFN) And Administration Of Heparin Loading Dose,” revised April 2025, stated, “ ... Skin Antiseptic Povidone Iodine ... Effective Contact Time 30 seconds Air Drying Time 2 minutes ... Procedure 1. Have patient wash access site with appropriate soap, if able. If patient unable to wash access site, patient care teammate will clean access extremity with skin cleansing agent and pat dry. ... 11. While maintaining aseptic technique, cleanse the site by applying skin antiseptic using a circular motion, moving from the center out and allow to dry. (For contact and dry time refer to table above). ... “ N.J.A.C. 8:43A-24.8(b)”

    Rule V0550. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 305 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 48966 Based on one of one observation of the medication preparation area, staff interviews, and review of Manufacturer’s Instructions for Use (MIFU), it was determined that the facility failed to ensure that bottles of LiquaCel (concentrated liquid protein supplement) are not available for use beyond the expiration date and are dated when opened. Findings include: On 05/27/25 at 11:25 AM, during an observation of the medication preparation area, three bottles of LiquaCel were found in the third drawer from the left of the cabinet. One apple flavored bottle had an open date of 05/23/25 and an expiration date of “10/24.” A half-empty bottle of grape flavored LiquaCel did not have a recorded date of when it was opened. During an interview at 11:32 AM, Staff (S)4 (Registered Nurse) confirmed that one LiquaCel bottle was not dated and the other LiquaCel bottle was expired. S4 stated that the LiquaCel bottles must be dated when first opened and should be used within three months of opening. S4 stated, “We just received some of these supplements” and then he/she discarded the two bottles. During an interview on 05/28/25 at 9:21 AM, S10 (Manager of Clinical Services) stated that LiquaCel is good for three months once opened or until the expiration date on the bottle. Review of the LiquaCel MIFU stated, “ ... Storage: may or may not be refrigerated. Do not use if safety seal is broken. Be sure to date when first opened. Use within three months of opening ... “”

    Rule V0715. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
May 29, 2025Standard inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Aug 14, 2015.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis and peritoneal dialysis.
  • Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
  • 19 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 5 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 55 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 12 dialysis facilities CMS lists in Monmouth County, 11 have a star rating from CMS: 2 rated 5 of 5, 4 rated 4 of 5, 2 rated 3 of 5, 3 rated 2 of 5.
  • CMS rates this one 5 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.