Hearth Record

Fmc Salem Dialysis

A dialysis facility in Salem, New Jersey 08079

#5 Route 45, Salem, New Jersey 08079. (856) 935-0949.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.

The last 24 months 5 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jan 19, 2024: a standard inspection.

5 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

5 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

5 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jan 19, 2024: standard inspection5 deficiencies
  • Roles Under A Waiver Declared By Secretary

    The inspectors’ words, 402 words

    “Roles Under a Waiver Declared by Secretary CFR(s): §403.748(b)(8), §416.54(b)(6), §418.113(b)(6)(C)(iv), §441.184(b)(8), §460.84(b)(9), §482.15(b)(8), §483.73(b)(8), §483.475(b)(8), §485.542(b)(7), §485.625(b)(8), §485.920(b)(7), §494.62(b)(7). [(b) Policies and procedures. The [facilities] must develop and implement emergency preparedness policies and procedures, based on the emergency plan set forth in paragraph (a) of this section, risk assessment at paragraph (a)(1) of this section, and the communication plan at paragraph (c) of this section. The policies and procedures must be reviewed and updated at least every 2 years [annually for LTC facilities]. At a minimum, the policies and procedures must address the following:] (8) [(6), (6)(C)(iv), (7), or (9)] The role of the [facility] under a waiver declared by the Secretary, in accordance with section 1135 of the Act, in the provision of care and treatment at an alternate care site identified by emergency management officials. *[For RNHCIs at §403.748(b):] Policies and procedures. (8) The role of the RNHCI under a waiver declared by the Secretary, in accordance with section 1135 of Act, in the provision of care at an alternative care site identified by emergency management officials. This Standard is not met as evidenced by: 35949 Based on facility policy review, document review, and interview, it was determined that the facility failed to develop policies and procedures to include the role of the facility under a waiver declared by the Secretary, in accordance with section 1135 of the Social Security Act, in the provision of care and treatment at an alternate care site as part of the emergency preparedness plan. Findings include: A review of a facility policy titled, “Guidelines for Emergency Preparedness,” dated 07/03/2023, revealed, “The Centers for Medicare and Medicaid Services (CMS), the Department of Labor Occupational Safety and Health Act (OSHA) and other Federal and State agencies each have requirements intended to ensure that staff and patients are provided safe and sanitary environments as well as training in emergency preparedness to assist with ongoing safety.” Review of the facility’s undated emergency preparedness plan revealed no evidence of the development of a policy or procedure that included the facility’s role, under the declaration of an 1135 waiver, in providing care at an alternative care site. During an interview on 01/19/2024 at 2:42 PM, the Director of Operations confirmed the information in question was not included in the facility’s emergency preparedness plan and stated the required information must have fallen “through the cracks” during the most recent revision.”

    Rule E0026. Standard-level.

  • Ic - Aseptic Techniques For Iv Meds

    The inspectors’ words, 314 words

    “IC-ASEPTIC TECHNIQUES FOR IV MEDS CFR(s): 494.30(b)(2) [The facility must-] (2) Ensure that clinical staff demonstrate compliance with current aseptic techniques when dispensing and administering intravenous medications from vials and ampules; and This Standard is not met as evidenced by: 35949 Based on observation, interview, and facility policy review, it was determined that the facility failed to utilize an aseptic technique while preparing intravenous (IV) medications during 2 of 2 observations. Findings include: During an observation on 01/19/2024 at 9:08 AM of the medication preparation area at the nurses’ station with the Clinical Manager (CM), Registered Nurse (RN) #3 used a needle attached to a syringe to puncture the diaphragm of a medication vial. RN #3 failed to disinfect the diaphragm of the medication vial before puncturing the septum with the needle. The CM stated staff were trained to disinfect the diaphragm of the medication vial before puncturing it with a needle attached to a syringe while preparing medications for administration. During an observation on 01/19/2024 at 9:22 AM, RN #3 used a needle attached to a syringe to puncture the diaphragm of a medication vial. RN #3 failed to disinfect the diaphragm of the medication vial before puncturing the septum with the needle. RN #3 confirmed she did not disinfect the diaphragm of the medication vial before puncturing it with a needle attached to a syringe. She stated that she had been trained to use an alcohol pad to disinfect the diaphragm. Review of a facility policy titled, “Medication Preparation and Administration,” dated 02/06/2023, revealed, “Infection Control” included “Cleanse the diaphragm of a vial with alcohol prior to accessing the vial. If the vial is a multidose vial, cleanse the diaphragm with a new alcohol pad each time the vial is accessed with a needle using friction and 70% [percent] alcohol. Allow to dry before inserting a device into the vial.” N.J.A.C. 8:43A-24.8(b)”

    Rule V0143. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 613 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 35949 Based on observation, interview, manufacturer’s directions for use (DFU) review, and facility procedure review, it was determined that the facility failed to adhere to the bloodline manufacturer’s DFU during dialysis treatments by not maintaining the arterial drip chamber fluid levels at 85 percent (%) to 95% full and by not maintaining the venous drip chamber fluid levels at 65% to 75% full during 3 of 3 observations. Findings include: Observation of the hemodialysis treatment area on 01/16/2024 from 10:45 AM to 11:30 AM, revealed the arterial drip chamber fluid levels were less than (<) 85% full in Stations 2, 3, 4, 5, 6, 10, 13, and 14, and the venous drip chamber fluid levels were greater than (>) 75% full in Stations 2, 3, 4, 5, 6, 10, and 14. Observation of the hemodialysis treatment area on 01/19/2024 at 8:55 AM, revealed the arterial drip chamber fluid levels were < 85% full and the venous drip chamber fluid levels were > 75% full in Stations 2, 3, 7, 14, 15, and 18. Observation of the hemodialysis treatment area on 01/19/2024 at 9:35 AM with the Clinical Manager (CM), revealed the arterial drip chamber fluid levels were < 85% full in Stations 2, 3, 4, 5, 7, 8, 14, 15, 16, 18, and 19, and the venous drip chamber fluid levels were > 75% full in Stations 2, 3, 5, 7, 14, 15, 16, and 18. During an interview on 01/19/2024 at 9:35 AM in the treatment area, the Clinical Manager acknowledged the arterial and venous drip chamber fluid levels were not maintained according to the manufacturer’s DFU. During an interview on 01/19/2024 at 9:45 AM, Registered Nurse (RN) #3 stated the chamber levels should be maintained three quarters full during dialysis treatments. RN #3 did not recall what levels were taught during training. Review of a facility procedure titled, “Initiation of Treatment Using an Arteriovenous Graft or Fistula and Optiflux Single Use Ebeam Dialyzer,” dated 07/06/2021, revealed that a “Final Machine Verification” section included, “Prior to starting the blood pump, verify the following: 1. All connections are secure. 2. Dialysate lines are attached properly to the dialyzer. 3. There is at least 300 ml [milliliters] of saline in the saline bag and the saline line is double clamped. 4. Any unused administration lines are clamped. 5. The arterial chamber is 85-95% full, and venous chamber is 65-75% full. 6. Arterial and venous monitoring transducers are securely connected, not wet with saline, and the transducer clamps are open. 7. Blood pump segment is threaded through the pump properly. 8. Venous drip chamber is correctly positioned in its housing and venous bloodline is threaded through venous occluding clamp. 9. No kinks or bends are evident in any of the tubing. 10. No air is noted in the dialyzer or bloodlines.” Review of a manufacturer’s DFU titled “Hemodialysis Blood Tubing Set with Priming Set and Transducer Protectors” revealed, “2. During Treatment” section that staff should “a. Periodically check the extracorporeal circuit for any evidence of possible Separation [sic] or leaks. b. Maintain fluid level in pre-pump arterial chamber at 85 to 95% full, post-pump arterial and venous chambers at 65 to 75% full. Levels may rise or drop during the treatment due to changes in pressure or flow rate. Readjust levels as needed. Air Leaks [sic] will also cause the chamber levels to fluctuate.” N.J.A.C. 8:43A-24.4(a)”

    Rule V0403. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 446 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 35949 Based on record review, interview, and facility policy review, it was determined that the facility failed to ensure staff documented the monitoring of patients during dialysis treatments according to policy for 2 (Patient #2 and Patient #3) of 4 sampled in-center patients. Findings include: 1. Review of Patient #2’s electronic “Treatment Sheet for Facility: [Name of facility]” from 01/01/2024 through 01/17/2024, revealed the following: - 01/10/2024 - There was no blood flow rate (BFR) or dialysate flow rate (DFR) documented between 9:39 AM and 11:01 AM (a duration of 82 minutes); and - 01/17/2024 - There was no BFR or DFR documented between 12:02 PM and 1:45 PM (a duration of 103 minutes). During an interview on 01/19/2024 at 12:49 PM, Registered Nurse (RN) #3 stated she was trained to document every 30 minutes during a patient’s dialysis treatment. During an interview on 01/19/2024 at 1:10 PM, Patient Care Technician (PCT) #9 stated she was trained to document every 30 minutes during a patient’s dialysis treatment. During an interview on 01/18/2024 at 2:25 PM, the Clinical Manager (CM) confirmed the patient’s treatment sheets lacked the required documented monitoring every 30 to 45 minutes per the facility policy. The CM stated staff were trained to document according to the facility’s policy. 2. Review of Patient #3’s electronic “Treatment Sheet for Facility: [Name of facility]” from 01/01/2024 through 01/17/2024 revealed that, on 01/06/2024, there was no blood pressure, blood flow rate (BFR), or dialysate flow rate (DFR) documented between 9:59 AM and 11:02 AM (duration of 63 minutes). During an interview on 01/19/2024 at 12:49 PM, Registered Nurse (RN) #3 stated she was trained to document every 30 minutes during a patient’s dialysis treatment. During an interview on 01/19/2024 at 1:10 PM, Patient Care Technician (PCT) #9 stated she was trained to document every 30 minutes during a patient’s dialysis treatment. During an interview on 01/18/2024 at 2:25 PM, the Clinical Manager (CM) confirmed the patient’s treatment sheet lacked the required documented monitoring every 30 to 45 minutes per the facility policy. The CM stated staff were trained to document according to the facility’s policy. Review of a facility policy titled, “Patient Monitoring and Safety Checks During Hemodialysis Treatment,” dated 09/05/2023, revealed “Monitor and document every 30 minutes or more frequently as needed but not to exceed 45 minutes or per state regulations in [Name of facility] Treatment Record.” N.J.A.C. 8:43A-24.4(a)”

    Rule V0543. Standard-level.

  • Achieve Adequate Clearance

    The inspectors’ words, 756 words

    “POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 35949 Based on record review, interview, and policy review, it was determined that the facility failed to follow individualized dialysis prescriptions as determined by a medical provider for 4 (Patients #1, #2, #3, and #4) of 7 sampled patients. Findings include: 1. Review of Patient #1’s “Patient Transfer” report revealed a prescribed blood flow rate (BFR) of 400 milliliters per minute (mL/min). Review of Patient #1’s electronic “Treatment Sheet for Facility: [Name of facility]” records from 01/01/2024 through 01/17/2024 indicated the following: - 01/04/2024 - The BFR was documented at 450 mL/min from 10:32 AM until 11:00 AM; - 01/06/2024 - The BFR was documented at 300 mL/min from 12:00 PM until 1:34 PM; - 01/13/2024 - The BFR was documented at 450 mL/min from 10:40 AM until 12:06 PM; and - 01/16/2024 - The BFR was documented at 450 mL/min from 11:02 AM until 12:32 PM. The record did not reveal a documented objective rationale for the change to the prescribed BFR. 2. Review of Patient #2’s “Patient Transfer” report and “Current Orders Report” revealed a prescribed blood flow rate (BFR) of 600 milliliters per minute (mL/min) and a prescribed dialysate flow rate (DFR) of 800 mL/min. Review of Patient #2’s electronic “Treatment Sheet for Facility: [Name of facility]” records from 01/01/2024 through 01/17/2024 indicated the following: - 01/05/2024 - The BFR was documented at 300 mL/min and the DFR was documented at 500 mL/min from 9:29 AM until 10:31 AM, and the BFR was documented at 350 mL/min and the DFR was documented at 600 mL/min from 10:31 AM until 12:02 PM; and - 01/10/2024 - The BFR was documented at 500 mL/min from 1:01 PM until the treatment was terminated at 2:00 PM. The record did not reveal a documented objective rationale for the change to the prescribed BFR or DFR. 3. Review of Patient #3’s “Patient Transfer” revealed a revealed a prescribed blood flow rate (BFR) of 450 milliliters per minute (mL/min). A review of Patient #3’s electronic “Treatment Sheet for Facility: [Name of facility]” records from 01/01/2024 through 01/17/2024 revealed the following: - 01/04/2024 - The BFR was documented at 400 mL/min from 10:31 AM until the treatment was terminated at 1:39 PM; - 01/09/2024 - The BFR was documented at 400 mL/min from 11:31 AM until the treatment was terminated at 1:24 PM; and - 01/13/2024 - The BFR was documented at 500 mL/min during the entire treatment, from 9:52 AM until 1:10 PM. The record did not reveal a documented objective rationale for the change to the prescribed BFR. 4. Review of Patient #4’s “Patient Transfer” report revealed a prescribed blood flow rate (BFR) of 450 milliliters per minute (mL/min). Review of Patient #4’s electronic “Treatment Sheet for Facility: [Name of facility]” from 01/01/2024 through 01/17/2024 indicated the following: - 01/04/2024 - The BFR was documented at 455 mL/min from 4:54 AM until 5:43 AM, and 400 mL/min from 5:43 AM until 6:32 AM; - 01/11/2024 - The BFR was documented at 400 mL/min from 6:00 AM until 9:05 AM; - 01/13/2024 - The BFR was documented at 400 mL/min from 6:30 AM until the treatment was terminated at 8:30 AM; and - 01/16/2024 - The BFR was documented at 425 mL/min from 5:31 AM until the treatment was terminated at 8:48 AM. The record did not reveal a documented objective rationale for the change to the prescribed BFR. During an interview on 01/19/2024 at 12:49 PM, Registered Nurse (RN) #3 stated staff were trained to document a rationale for changes to a patient’s prescribed BFR and dialysis flow rate (DFR). During an interview on 01/18/2024 at 2:25 PM, the Clinical Manager (CM) confirmed the treatment sheets lacked documentation regarding why changes occurred to the patient’s prescribed BFR. The CM stated staff were trained to document rationales when the BFR was not achieved. During an interview on 01/19/2024 at 12:35 PM, the Medical Director stated staff were expected to include rationales for changes to a patient’s prescribed BFR and DFR. Review of a facility policy titled, “Physician Order Documentation,” dated 07/03/2023, revealed “Nurse practice acts require nurses to carry out treatment care, medication administration, lab tests, procedures, and other treatments, based on physician orders.” N.J.A.C. 8:43A-24.4(a)”

    Rule V0544. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jan 19, 2024Standard inspection5 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Nov 1, 2000.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
  • Doesn’t offer a shift starting at 5 p.m. or later.
  • 19 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • No other dialysis facility CMS lists is in Salem County.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.