Fresenius Medical Care Farmville
A dialysis facility in Farmville, North Carolina 27828
4302 S. Main Street, Farmville, North Carolina 27828. (252) 753-0092.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 3 deficiencies cited in the last three years
- 14 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jan 30, 2025: a standard inspection.
3 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
3 deficiencies in 1 month of the last 36. Last cited Jan 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jan 30, 2025: standard inspection3 deficiencies
-
Manage Volume Status
The inspectors’ words, 1,073 words
“POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 38766 Based on facility policy review, medical record reviews, and staff interviews, the facility staff failed to monitor a patient at least every 30-45 minutes during hemodialysis treatments for 4 of 9 sampled in-center hemodialysis records reviewed (Patient #7, #9, #5, and #3). Findings included: A review on 01/29/2025 of the facility policy titled, “Patient Assessment and Monitoring,” published 05/01/2023, revealed, “... During Treatment: Obtain blood pressure and pulse rate every 30 minutes or more as needed but not to exceed 45 minutes per state regulations. Document machine parameters and safety checks every 30 minutes or more often as needed but not to exceed 45 minutes or per state regulations.” 1. Open medical record review on 01/30/2025 for Patient #7 revealed a 40-year-old male admitted to the facility for ICHD treatments on 10/24/2018. A review of the treatment sheet dated 01/21/2025 revealed the treatment started at 0600 and ended at 1139 for 279 minutes. The review of the monitoring documentation dated 01/21/2025 revealed Patient #7’s blood pressure, pulse, and machine parameters were monitored by staff at 0600 and monitored next by staff at 0857 (177 minutes later). The review revealed the facility staff failed to monitor the patient’s blood pressure, pulse, and machine parameters at least every 30-45 minutes during the hemodialysis treatment on 01/21/2025. An interview on 01/30/2025 at 1315 with the Clinical Manager revealed that the policy required patients to be monitored every 30-45 minutes. However, staff were expected to monitor patients every 30 minutes during treatments. The interview revealed the staff monitored vital signs, visualized the access sites, and checked for wet transducers and machine parameters. The interview revealed that the staff should have documented the monitoring in the patient’s treatment record. The interview revealed the staff failed to follow the facility policy. 2. Open medical record review on 01/30/2025 for Patient #9 revealed a 67-year-old female admitted to the facility for ICHD treatments on 05/10/2022. A review of the treatment sheet dated 01/14/2025 revealed the treatment started at 1208 and ended at 1540 for 212 minutes. The review of the monitoring documentation dated 01/14/2025 revealed Patient #9’s blood pressure, pulse, and machine parameters were monitored by staff at 1433 and monitored next by staff at 1526 (53 minutes later). A review of the treatment sheet dated 01/21/2025 revealed the treatment started at 1204 and ended at 1545 for 221 minutes. The review of the monitoring documentation dated 01/21/2025 revealed Patient #9’s blood pressure, pulse, and machine parameters were monitored by staff at 1239 and monitored next by staff at 1405 (86 minutes later) and again at 1503 (58 minutes). A review of the treatment sheet dated 01/24/2025 revealed the treatment started at 1125 and ended at 1455 for 210 minutes. The review of the monitoring documentation dated 01/24/2025 revealed Patient #9’s blood pressure, pulse, and machine parameters were monitored by staff at 1341 and monitored next by staff at 1440 (59 minutes later). The review revealed the facility staff failed to monitor the patient’s blood pressure, pulse, and machine parameters at least every 30-45 minutes during the hemodialysis treatment on 01/14/2025, 01/21/2025, and 01/24/2025. An interview on 01/30/2025 at 1315 with the Clinical Manager revealed that the policy required patients to be monitored every 30-45 minutes. However, staff were expected to monitor patients every 30 minutes during treatments. The interview revealed the staff monitored vital signs, visualized the access sites, and checked for wet transducers and machine parameters. The interview revealed that the staff should have documented the monitoring in the patient’s treatment record. The interview revealed the staff failed to follow the facility policy. 3. Open medical record review on 01/29/2025 for Patient #5 revealed a 63-year-old female admitted to the facility for ICHD treatments on 11/17/2022. A review of the treatment sheet dated 01/14/2025 revealed the treatment started at 0618 and ended at 1018 for 240 minutes. The review of the monitoring documentation dated 01/14/2025 revealed Patient #5’s blood pressure, pulse, and machine parameters were monitored by staff at 0715 and monitored next by staff at 0811 (56 minutes later). A review of the treatment sheet dated 01/24/2025 revealed the treatment started at 1340 and ended at 1707 for 207 minutes. The review of the monitoring documentation dated 01/14/2025 revealed Patient #5’s blood pressure, pulse, and machine parameters were monitored by staff at 1456 and monitored next by staff at 1604 (68 minutes later). The review revealed the facility staff failed to monitor the patient’s blood pressure, pulse, and machine parameters at least every 30-45 minutes during the hemodialysis treatment on 01/14/2025 and 01/24/2025. An interview on 01/30/2025 at 1315 with the Clinical Manager revealed that the policy required patients to be monitored every 30-45 minutes. However, staff were expected to monitor patients every 30 minutes during treatments. The interview revealed the staff monitored vital signs, visualized the access sites, and checked for wet transducers and machine parameters. The interview revealed that the staff should have documented the monitoring in the patient’s treatment record. The interview revealed the staff failed to follow the facility policy. 4. Open medical record review on 01/29/2025 for Patient #3 revealed a 40-year-old male admitted to the facility for ICHD treatments on 06/25/2024. A review of the treatment sheet dated 01/17/2025 revealed the treatment started at 0753 and ended at 1154 for 241 minutes. The review of the monitoring documentation dated 01/17/2025 revealed Patient #3’s blood pressure, pulse, and machine parameters were monitored by staff at 0823 and monitored next by staff at 0921 (58 minutes later). The review revealed the facility staff failed to monitor the patient’s blood pressure, pulse, and machine parameters at least every 30-45 minutes during the hemodialysis treatment on 01/17/2025. An interview on 01/30/2025 at 1315 with the Clinical Manager revealed that the policy required patients to be monitored every 30-45 minutes. However, staff were expected to monitor patients every 30 minutes during treatments. The interview revealed the staff monitored vital signs, visualized the access sites, and checked for wet transducers and machine parameters. The interview revealed that the staff should have documented the monitoring in the patient’s treatment record. The interview revealed the staff failed to follow the facility policy.”
-
Achieve Adequate Clearance
The inspectors’ words, 1,020 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 38766 Based on facility policy review, medical record reviews, and staff interviews, the facility staff failed to follow the adequacy plan of care by not dialyzing patients at the prescribed blood flow rate for 4 of 9 sampled in-center hemodialysis records reviewed (Patients #1, #2, #3, and #6). Findings include: A review on 01/28/2025 of the facility policy titled “Patient Assessment and Monitoring,” published 05/01/2023, revealed, “Purpose...Responsibility...Definitions...Delegation...Data Collection...Pre-Treatment...During Treatment...Step 1...Step 3 [space] Machine Parameters and Extracorporeal Circuit [space] Check machine settings and measurements: Check prescribed blood flow is being achieved or reason is documented in medical record if unable to meet prescribed blood flow...Post-Treatment...” 1. Open medical record review on 01/28/2025 for Patient #1 revealed a 58-year-old male admitted to the facility for ICHD treatments on 12/27/2024. A review of the patient’s dialysis prescription orders revealed the patient’s prescribed BFR was 400 mL/min, and DFR was autoflowed at 1.5. A review of the patient’s Post Treatment Dialysis flowsheets from 01/13/2025 through 01/20/2025 revealed the facility staff failed to dialyze the patient at his ordered BFR and/or DFR for implementation of the patient’s adequacy plan as follows: ~Treatment on 01/15/2025 from 1240 to 1643 for 243 minutes had “350” average BFR and ~Treatment on 01/17/2025 from 1220 to 1623 for 243 minutes had an “800” average DFR. The review of the patient treatment sheets revealed the facility staff failed to dialyze the patient at his ordered BFR of “400” in 1 of 4 treatments and DFR of “autoflow 1.5” in 1 of 4 treatments, with no documentation for the decreased BFR/DFR and nurse notification. An interview on 01/30/2025 at 1315 with the Clinical Manager revealed that the BFR/DFR were ordered by the provider, and the staff was expected to follow the provider’s orders. The interview revealed the facility’s patient care technicians should notify the nursing staff anytime they increase/decrease the patient’s BFR and/or DFR. The interview revealed the nursing staff should have assessed and documented the reason for the decrease/increase of the BFR/DFR during the patient’s treatments. 2. Open medical record review on 01/28/2025 for Patient #2 revealed a 36-year-old female admitted to the facility for ICHD treatments on 07/03/2024. A review of the patient’s dialysis prescription orders revealed the patient’s prescribed BFR was 400 mL/min and DFR was 800 mL/min. A review of the patient’s Post Treatment Dialysis flowsheets from 01/13/2025 through 01/24/2025 revealed the facility staff failed to dialyze the patient at her ordered BFR and/or DFR for implementation of the patient’s adequacy plan as follows: ~Treatment on 01/13/2025 from 1134 to 1346 for 132 minutes had a “300” average BFR. The review of the patient treatment sheets revealed the facility staff failed to dialyze the patient at her ordered BFR of “400” in 1 of 6 treatments with no documentation for the decreased BFR and nurse notification. An interview on 01/30/2025 at 1315 with the Clinical Manager revealed that the BFR/DFR were ordered by the provider, and the staff was expected to follow the provider’s orders. The interview revealed the facility’s patient care technicians should notify the nursing staff anytime they increase/decrease the patient’s BFR and/or DFR. The interview revealed the nursing staff should have assessed and documented the reason for the decrease/increase of the BFR/DFR during the patient’s treatments. 3. Open medical record review on 01/29/2025 for Patient #3 revealed a 40-year-old male admitted to the facility for ICHD treatments on 06/25/2024. A review of the patient’s dialysis prescription orders revealed the patient’s prescribed BFR was 450 mL/min and DFR was 800 mL/min. A review of the patient’s Post Treatment Dialysis flowsheets from 01/14/2025 through 01/27/2025 revealed the facility staff failed to dialyze the patient at his ordered BFR and/or DFR for implementation of the patient’s adequacy plan as follows: ~Treatment on 01/14/2025 from 0743 to 1203 for 260 minutes had a “400” average BFR and a “750” average DFR. The review of the patient treatment sheets revealed the facility staff failed to dialyze the patient at his ordered BFR of “450” in 1 of 6 treatments and DFR of “800 mL/min” in 1 of 6 treatments, with no documentation for the decreased BFR/DFR and nurse notification. An interview on 01/30/2025 at 1315 with the Clinical Manager revealed that the BFR/DFR were ordered by the provider, and the staff was expected to follow the provider’s orders. The interview revealed the facility’s patient care technicians should notify the nursing staff anytime they increase/decrease the patient’s BFR and/or DFR. The interview revealed the nursing staff should have assessed and documented the reason for the decrease/increase of the BFR/DFR during the patient’s treatments. 4. Open medical record review on 01/29/2025 for Patient #6 revealed a 56-year-old male admitted to the facility for ICHD treatments on 07/09/2024. A review of the patient’s dialysis prescription orders revealed the patient’s prescribed BFR was 400 mL/min and DFR was 800 mL/min. A review of the patient’s Post Treatment Dialysis flowsheets from 01/14/2025 through 01/24/2025 revealed the facility staff failed to dialyze the patient at his ordered BFR for implementation of the patient’s adequacy plan as follows: ~Treatment on 01/18/2025 from 1159 to 1559 for 240 minutes had a “250” average BFR. The review of the patient treatment sheets revealed the facility staff failed to dialyze the patient at his ordered BFR of “400” in 1 of 6 treatments with no documentation for the decreased BFR and nurse notification. An interview on 01/30/2025 at 1315 with the Clinical Manager revealed that the BFR/DFR were ordered by the provider, and the staff was expected to follow the provider’s orders. The interview revealed the facility’s patient care technicians should notify the nursing staff anytime they increase/decrease the patient’s BFR and/or DFR. The interview revealed the nursing staff should have assessed and documented the reason for the decrease/increase of the BFR/DFR during the patient’s treatments.”
-
Md Resp - Ensure All Adhere To P&P
The inspectors’ words, 469 words
“MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 38766 Based on medical record review and staff interviews, the facility staff failed to promote patient safety by dialyzing a patient without wearing a LifeVest, as ordered by a provider. Findings included: An open medical record review on 01/29/2025 for Patient #7 revealed a 40-year-old male was admitted to the facility for ICHD treatments on 10/24/2018. A review of the patient’s record revealed the patient was hospitalized on 11/12/2024 through 11/22/2024 with a diagnosis of cardiac arrest. The review revealed that the patient had refused the placement of an Automatic Implantable Cardioverter-Defibrillator (AICD - a small device that monitors the heart rhythm and delivers an electrical shock if it detects a life-threatening arrhythmia). The patient got a LifeVest (a wearable defibrillator that monitors the heart and delivers a shock to treat life-threatening arrhythmias). The hospital record revealed that the hospital had consulted with the Nephrologist regarding whether the dialysis center would take the patient with a LifeVest. A review of provider notes on 12/18/2024 revealed, “...I have reinforced the need that he wears the LifeVest to dialysis in order to receive outpatient ICHD...” A review of the patient’s order written on 12/20/2024 revealed “Special Attention: Patient may not dialyze without WEARING Zoll LifeVest. Please contact the Named Provider or Named Nurse Practitioner in any issues arise between staff and patient...” A review of the patient’s Post Treatment Dialysis flowsheets from 01/13/2025 through 01/24/2025 revealed the facility staff failed to follow the provider’s order as follows: ~Treatment on 01/17/2025 from 0653 to 1056 with a nursing comment “pt. (patient) states not feeling well, not wearing the LifeVest...” ~Treatment on 01/20/2025 from 0710 to 1126 with a nursing comment “pt. (patient) did not wear lifeVest during treatment...” The review of the patient treatment sheets revealed the facility staff failed to follow the orders and dialyzed the patient without wearing the LifeVest in 2 of 6 treatments. An interview on 01/30/2025 at 1140 with the Clinical Manager revealed that the patient had had several cardiac events and was supposed to wear a LifeVest during treatment per the Medical Director. The interview revealed that the nurses were to visualize that the patient had the LifeVest before the start of every treatment. Further interviews revealed that the medical director had informed the patient that he had to wear the LifeVest, and that was the condition under which he was accepted to continue being treated while remaining a full code. The interview confirmed that the policy was not followed.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jan 30, 2025 | Standard inspection | 3 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Feb 29, 2016.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 14 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 4 dialysis facilities CMS lists in Pitt County, 4 have a star rating from CMS: 1 rated 4 of 5, 2 rated 3 of 5, 1 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Fmc - Greenville Dialysis Center | 3 |
| Fmc Dialysis Services East Carolina University | 2 |
| Fresenius Kidney Care Captains Cove | 4 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.