Davita Lumbee River Dialysis
A dialysis facility in Red Springs, North Carolina 28377
11016 Red Springs Road, Red Springs, North Carolina 28377. (910) 843-3205.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 5of 5 CMS’s star rating
- Not rated patient survey rating
- 3 deficiencies cited in the last three years
- 10 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jan 8, 2026: a standard inspection.
3 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
3 deficiencies in 1 month of the last 36. Last cited Jan 2026. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jan 8, 2026: standard inspection3 deficiencies
-
Ic - Staff Education Re Catheters/Catheter Care
The inspectors’ words, 423 words
“IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 26622 Based on policy review, observation and interview, the patient care staff failed to disinfect the CVC (Central Venous Catheter) hubs per facility policy in one of two observation during a hemodialysis treatment discontinuation using a CVC (PCT #1, Station #2). Findings include: Review on 01/07/2026 of the facility policy titled “Central Venous Catheter (CVC) with Clearguard HD Antimicrobial End Caps Procedure” revised April 2025 revealed “... 34. Remove syringes and disinfect the CVC hubs with a new alcohol prep pad for each CVC hub. Scrub the sides, threads and end of hub thoroughly with friction for 15 seconds. Remove any residue, for example blood. Hold the catheter until the antiseptic has dried. ...” Observation on 01/07/2026 at 1030 in the patient treatment area revealed PCT #1 entered Station #2 and initiated termination of a Central Venous Catheter (CVC). Observation revealed PCT #1 performed hand hygiene and applied clean gloves. Observation revealed PCT #1 cleansed the arterial catheter hub and the venous catheter hubs for less than 15 seconds each. The observation revealed that PCT #1 failed to disinfect each catheter hub for 15 seconds per facility policy. Observation revealed the facility policy was not followed. Interview on 01/07/2026 at 1040 with PCT #1 revealed the PCT stated that the hubs were disinfected for 15 seconds. Interview revealed that PCT #1 did not watch the clock while disinfecting the catheter hubs. Interview on 01/07/2026 at 1230 with the Manager of Clinical Services and Facility Administrator revealed that the staff were expected to scrub each catheter hub with an alcohol pad for fifteen (15) seconds per facility policy. Interview revealed the staff failed to follow the facility policy.”
-
Achieve Adequate Clearance
The inspectors’ words, 881 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 26622 V 544 Based on policy review, medical records review, and staff interviews, the facility staff failed to follow the adequacy plan of care by not dialyzing 3 of 6 (Patients #1, #2, and #6) in-center hemodialysis patients at the prescribed Blood Flow Rate (BFR)/Dialysate Flow Rate (DFR). Findings include: Review on 01/08/2026 of the facility policy titled “PRE-INTRA-POST TREATMENT DATA COLLECTION, MONITORING AND NURSING ASSESSMENT” revised April 2024 revealed “INTRADIALYTIC DATA COLLECTION/ASSESSMENT ... 9. ... b. At a minimum, obtain and document the following: ... iii. Blood and dialysate flows, arterial and venous pressures ... 10. If the dialysis prescription is not being met (including dialysis flow rate or change to/inability to obtain prescribed blood flow rate) the reason will be documented and the licensed nurse informed.” 1. Review on 01/07/2026 of the medical record for Patient #1 revealed a 60-year-old male that had been admitted to the facility for in-center hemodialysis (ICHD) treatment on 11/12/2025. A review of the Physician orders revealed Patient #1’s Dialysate Flow Rate (DFR) was ordered at 800 with a treatment duration order for 4 hours (hrs). Review of the Treatment Flowsheet dated 12/31/2025 revealed Patient #1’s hemodialysis treatment was initiated at 1206 and ended at 1605 for a duration of 4 hrs and 1 minute. Review of the Flowsheet revealed Patient #1’s DFR average was 570, with no documentation for the decreased DFR and no documentation of the Registered Nurse notification. Review of the Treatment Flowsheet dated 01/02/2026 revealed Patient #1’s hemodialysis treatment was initiated at 1202 and ended at 1604 for a duration of 4 hrs and 3 minutes. Review of the flowsheet revealed Patient #1’s DFR average was 500, with no documentation for the decreased DFR and no documentation of the Registered Nurse notification. Interview on 01/08/2026 at 1100 with the Facility Administrator and Operations Director revealed that the patient care technicians were expected to notify the nursing staff anytime they increased and/or decreased the patient’s DFR and document in the medical record. The interview revealed that the nursing staff should have assessed and documented the reason for the decreased DFR during the patient’s treatment. 2. Review on 01/07/2026 of the medical record for Patient #2 revealed a 51-year-old male that had been admitted to the facility for in-center hemodialysis (ICHD) treatment on 09/10/2025. A review of the Physician orders revealed Patient #2’s Blood Flow Rate (BFR) was ordered at 350 and Dialysate Flow Rate (DFR) was ordered at 800 with a treatment duration order for 4 hours (hrs). Review of the Treatment Flowsheet dated 12/31/2025 revealed Patient #2’s hemodialysis treatment was initiated at 1105 and ended at 1503 for a duration of 3 hrs and 56 minutes. Review of the Flowsheet revealed Patient #2’s BFR average was 355 and DFR average was 500, with no documentation for the increased BFR and decreased DFR, and no documentation of the Registered Nurse notification. Review of the Treatment Flowsheet dated 01/02/2026 revealed Patient #2’s hemodialysis treatment was initiated at 0943 and ended at 1343 for a duration of 3 hrs and 55 minutes. Review of the flowsheet revealed Patient #2’s BFR average was 305 and DFR average was 500, with no documentation for the decreased BFR/DFR and no documentation of the Registered Nurse notification. Interview on 01/08/2026 at 1100 with the Facility Administrator and Operations Director revealed that the patient care technicians were expected to notify the nursing staff anytime they increased and/or decreased the patient’s BFR/DFR and document in the medical record. The interview revealed that the nursing staff should have assessed and documented the reason for the increased/decreased BFR and decreased DFR during the patient’s treatment. 3. Review on 01/07/2026 of the medical record for Patient #6 revealed a 61-year-old female that had been admitted to the facility for in-center hemodialysis (ICHD) treatment on 08/02/2023. A review of the Physician orders revealed Patient #6’s Dialysate Flow Rate (DFR) was ordered at 800 with a treatment duration order for 4 hours (hrs). Review of the Treatment Flowsheet dated 12/31/2025 revealed Patient #6’s hemodialysis treatment was initiated at 0630 and ended at 1032 for a duration of 4 hrs. Review of the Flowsheet revealed Patient #6’s DFR average was 500, with no documentation for the decreased DFR and no documentation of the Registered Nurse notification. Review of the Treatment Flowsheet dated 01/02/2026 revealed Patient #6’s hemodialysis treatment was initiated at 0630 and ended at 1033 for a duration of 3 hrs and 58 minutes. Review of the flowsheet revealed Patient #6’s DFR average was 500, with no documentation for the decreased DFR and no documentation of the Registered Nurse notification. Interview on 01/08/2026 at 1100 with the Facility Administrator and Operations Director revealed that the patient care technicians were expected to notify the nursing staff anytime they increased and/or decreased the patient’s DFR and document in the medical record. The interview revealed that the nursing staff should have assessed and documented the reason for the decreased DFR during the patient’s treatment.”
-
Vascular Access - Monitor/Referrals
The inspectors’ words, 593 words
“POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 26622 Based on policy and procedure review, observations, and staff interviews, the facility failed to ensure staff performed skin antisepsis per policy before cannulation of 2 of 3 Arterio-venous fistula/graft (AVF/AVG) cannulation procedures observed (Station #12; PCT #2 and Station #1; PCT #1). Findings included: Review on 01/07/2026 of the facility policy titled “AV (Arterio-venous) Fistula or Graft Cannulation ...” revised April 2025 revealed “ ... Skin Antiseptic: Povidone Iodine; Effective Volume: At least 1 prep pad per site or 1 saturated sterile gauze pad per site; Effective Contact Time: 30 seconds; Air Drying Time: 2 minutes ... Procedure ... 11. While maintaining aseptic technique, cleanse the site by applying skin antiseptic using a circular rubbing motion, moving from the center out and allow to dry. (For contact and dry time refer to the table above). ...” 1. Observation on 01/07/2026 at 0855 in the patient treatment area revealed PCT #2 entered Station #12 and initiated access of an Arterio-Venous fistula/graft (AVF/G) for hemodialysis treatment. PCT #2 performed hand hygiene and applied clean gloves. PCT #2 cleansed the arterial and venous access sites with Povidone Iodine pad for less than 30 seconds at each site. PCT #2 allowed the access sites to dry for 2 minutes before cannulation. Observation revealed PCT #2 failed to disinfect each access site with Povidone Iodine for 30 seconds. Interview on 01/07/2026 at 0900 with PCT #2 revealed that each site should be disinfected for 30 seconds. PCT #2 believed that she had cleaned each site for 30 seconds but admitted that she did not use the clock. Interview revealed that PCT #2 failed to disinfect the access sites per facility policy. Interview on 01/07/2026 at 1230 with the Manager of Clinical Services and Facility Administrator revealed the staff were expected to disinfect each access site for 30 seconds when using Povidone Iodine pads and allow each site to dry for 2 minutes, prior to cannulating. Interview revealed the staff failed to follow the facility policy. 2. Observation on 01/07/2026 at 1055 in the patient treatment area revealed PCT #1 entered Station #1 and initiated access of an Arterio-Venous fistula/graft (AVF/G) for hemodialysis treatment. PCT #1 performed hand hygiene and applied clean gloves. PCT #1 cleansed the arterial and venous access sites with Povidone Iodine pad for 15 seconds at each site. PCT #1 allowed the access sites to dry for 2 minutes before cannulation. Observation revealed PCT #1 failed to disinfect each access site with Povidone Iodine for 30 seconds. Interview on 01/07/2026 at 1055 with PCT #1 revealed that each site should be disinfected for 30 seconds and allowed to dry for 1 (one) minute. PCT #1 believed that she had cleaned each site for 30 seconds but admitted that she did not use the clock. Interview revealed that PCT #1 failed to disinfect the access sites per facility policy. Interview on 01/07/2026 at 1230 with the Manager of Clinical Services and Facility Administrator revealed the staff were expected to disinfect each access site for 30 seconds when using Povidone Iodine pads and allow each site to dry for 2 minutes, prior to cannulating. Interview revealed the staff failed to follow the facility policy.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jan 8, 2026 | Standard inspection | 3 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Mar 7, 2014.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
- Doesn’t offer a shift starting at 5 p.m. or later.
- 10 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 5 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 5 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 6 dialysis facilities CMS lists in Robeson County, 6 have a star rating from CMS: 1 rated 5 of 5, 3 rated 3 of 5, 1 rated 2 of 5, 1 rated 1 of 5.
- CMS rates this one 5 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.