Davita Dialysis Care of Martin County
A dialysis facility in Williamston, North Carolina 27892
100 Medical Drive, Williamston, North Carolina 27892. (252) 792-2386.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 2of 5 CMS’s star rating
- 4of 5 patient survey rating
- 4 deficiencies cited in the last three years
- 25 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Feb 14, 2025: a standard inspection.
4 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 1 month of the last 36. Last cited Feb 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Feb 14, 2025: standard inspection4 deficiencies
-
Ic - Supply Cart Distant/No Supplies In Pockets
The inspectors’ words, 362 words
“IC-SUPPLY CART DISTANT/NO SUPPLIES IN POCKETS CFR(s): 494.30(a)(1)(i) If a common supply cart is used to store clean supplies in the patient treatment area, this cart should remain in a designated area at a sufficient distance from patient stations to avoid contamination with blood. Such carts should not be moved between stations to distribute supplies. Do not carry medication vials, syringes, alcohol swabs or supplies in pockets. This Standard is not met as evidenced by: 26622 Based on policy review, observations, and staff interviews, the facility staff failed to prevent cross-contamination by failing to disinfect a dialysis station chair prior to setting up the dialysis machine for a new patient for 1 of 2 cleaning of dialysis station observed (Station #12). Findings Included: Review on 02/14/2025 of current facility policy “Infection Control For Dialysis Facilities”, Policy: 1-05-01, revised 4/2023, revealed “PURPOSE: To minimize the spread of infections or blood borne pathogens in the dialysis facility environment. ... Disinfection ... 13. At the end of each treatment, the dialysis station will be cleaned and disinfected. a. Surfaces to be disinfected include but are not necessarily limited to: all surfaces in contact with the patient or their belongings (e.g., dialysis chair...) ...” Observation on 02/12/2025 at 1030 in the patient treatment area revealed Hemodialysis Machine (HDM) #38 located at Station #12 was set up with new dialysis tubing, dialyzer and fluids and ready for patient use. The observation revealed that PCT #2 was disinfecting the dialysis chair in Station #12. The observation revealed that PCT #2 failed to clean the dialysis chair prior to setting up the dialysis machine for the next patient. Interview on 02/12/2025 at 1030 during the observation with PCT #2 revealed the dialysis station chair should have been cleaned/disinfected prior to setting up the hemodialysis machchine for the next patient. Interview revealed the staff failed to follow the facility policy. Interview on 02/12/2025 at 1230 with the Manager of Clinical Services revealed that the dialysis chair should have been cleaned/disinfected prior to setting up the dialysis machine for another patient. Interview revealed the dialysis station that included the chair and the dialysis machine should be cleaned at the same time.”
-
Manage Volume Status
The inspectors’ words, 393 words
“POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 26622 Based on facility policy review, medical record reviews, and staff interview, the facility staff failed to ensure machine prescription verifications were performed by a nurse within one hour of initiation of hemodialysis treatment in 2 of 5 (Patients #3 and #4) sampled in-center hemodialysis records reviewed. Findings include: Review on 02/14/2025 of the facility policy titled “PRE-INTRA-POST TREATMENT DATA COLLECTION, MONITORING AND NURSING ASSESSMENT” revised April 2024 revealed “Policy .... 3. Patient identity, prescription and machine settings are verified by teammate prior to initiation of treatment ... The prescription components are confirmed by a licensed nurse within one (1) hour of treatment initiation ...” 1. Review of the medical record for Patient #3 revealed a 68-year-old male admitted for In-Center Hemodialysis treatments on 11/10/2020. Review of the Treatment Flowsheet dated 01/29/2025 revealed Patient #3’s treatment was initiated at 0550. Review of the Flowsheet revealed the Registered Nurse Machine Verification was performed at 0706 (1 hour and 16 minutes after initiation of treatment). Review of the Treatment Flowsheet dated 02/07/2025 revealed Patient #3’s treatment was initiated at 0551. Review of the Flowsheet revealed the Registered Nurse Machine Verification was performed at 0653 (1 hour and 2 minutes after initiation of treatment). Interview on 02/14/2025 at 1030 with the Manager of Clinical Services revealed the Registered Nurse was expected to document the machine verification within one (1) hour of the patient dialysis treatment initiation time. Interview revealed the Registered Nurse failed to follow the facility policy. 2. Review of the medical record for Patient #4 revealed a 74-year-old female admitted for In-Center Hemodialysis treatments on 01//23/2024. Review of the Treatment Flowsheet dated 01/28/2025 revealed Patient #4’s treatment was initiated at 0852. Review of the Flowsheet revealed the Registered Nurse Machine Verification was performed at 1049 (1 hour and 57 minutes after initiation of treatment). Interview on 02/14/2025 at 1030 with the Manager of Clinical Services revealed the Registered Nurse was expected to document the machine verification within one (1) hour of the patient dialysis treatment initiation time. Interview revealed the Registered Nurse failed to follow the facility policy.”
-
Achieve Adequate Clearance
The inspectors’ words, 1,270 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 26622 Based on policy review, medical record review, and staff interview the facility staff failed to follow the adequacy plan of care by failing to dialyze 4 of 5 (Patient #1, #3, #4 and #5) in-center hemodialysis patients at the prescribed BFR/DFR and/or treatment duration. Findings included: Review on 02/14/2025 of the facility policy titled “PRE-INTRA-POST TREATMENT DATA COLLECTION, MONITORING AND NURSING ASSESSMENT” revised April 2024 revealed “INTRADIALYTIC DATA COLLECTION/ASSESSMENT ... 9. ... b. At a minimum, obtain and document the following: ... iii. Blood and dialysate flows, arterial and venous pressures ... 10. If the dialysis prescription is not being met (including dialysis flow rate or change to/inability to obtain prescribed blood flow rate) the reason will be documented and the licensed nurse informed.” 1. Review of the medical record for Patient #1 revealed a 73-year-old female admitted for In-Center Hemodialysis treatments on 01/06/2025. Review of the Physician orders revealed Patient #1’s Blood Flow Rate (BFR) was ordered at 400 and Dialysate Flow Rate (DFR) at 600. Review of the Treatment Flowsheet dated 01/29/2025 revealed Patient #1’s hemodialysis treatment was initiated at 0814 and ended at 1235 (231 of 240 minutes). Review of the Flowsheet revealed Patient #1’s BFR average was 325, with no documentation for the decreased BFR and no documentation of the Registered Nurse notification. Review of the Treatment Flowsheet dated 02/05/2025 revealed Patient #1’s hemodialysis treatment was initiated at 0926 and ended at 1327 (226 minutes). Review of the Flowsheet revealed Patient #1’s BFR average was 287 with no documentation for the decreased BFR and no documentation of the Registered Nurse notification. Review of the Treatment Flowsheet dated 02/07/2025 revealed Patient #1’s hemodialysis treatment was initiated at 0915 and ended at 1325 (241 minutes). Review of the Flowsheet revealed Patient #1’s BFR average was 375 with no documentation for the decreased BFR and no documentation of the Registered Nurse notification. Review of the treatment sheets revealed that Patient #1’s blood flow rate was decreased in 3 of 6 treatments with no notification of the registered nurse. Interview on 02/14/2025 at 1030 with the Manger of Clinical Services revealed the facility’s patient care technicians should notify the nursing staff anytime they increased and/or decreased the patient’s BFR/DFR or were unable to achieve the ordered BFR/DFR. The interview further revealed that the nursing staff should have assessed and documented the reason for the decreased BFR during the patient treatments. The interview confirmed the medical record findings that patient #1 had a decreased BFR in 3 of 6 treatments with no documentation for the decreased BFR and Registered Nurse notification. 2. Review of the medical record for Patient #3 revealed a 68-year-old male admitted for In-Center Hemodialysis treatments on 11/10/2020. Review of the Physician orders revealed Patient #3’s Blood Flow Rate (BFR) was ordered at 450 and Dialysate Flow Rate (DFR) at 600. Review of the Treatment Flowsheet dated 01/31/2025 revealed Patient #3’s hemodialysis treatment was initiated at 0550 and ended at 0934 (193 of 225 minutes). Review of the Flowsheet revealed Patient #3’s BFR average was 406 with no documentation for the decreased BFR and no documentation of the Registered Nurse notification. Review of the Flowsheet revealed Patient #3’s hemodialysis treatment was shortened by 32 minutes, with no documentation for the shortened treatment or leaving against medical advice form. Review of the Treatment Flowsheet dated 02/07/2025 revealed Patient #3’s hemodialysis treatment was initiated at 0559 and ended at 0916 (196 of 225 minutes). Review of the Flowsheet revealed Patient #3’s hemodialysis treatment was shortened by 29 minutes, with no documentation for the shortened treatment or leaving against medical advice form. Review of the treatment sheets revealed that Patient #3’s blood flow rate and/or treatment duration was decreased in 2 of 6 treatments with no notification of the registered nurse. Interview on 02/14/2025 at 1030 with the Manger of Clinical Services revealed the facility’s patient care technicians should notify the nursing staff anytime they increased and/or decreased the patient’s BFR/DFR or were unable to achieve the ordered BFR/DFR. The interview further revealed that the nursing staff should have assessed and documented the reason for the decreased BFR during the patient treatments. Interview revealed the facility staff were expected to run patients for the prescribed treatment duration and to have the patient sign an against medical advice form if treatment was shortened. The interview confirmed the medical record findings that patient #3 had a decreased BFR/treatment duration in 2 of 6 treatments with no documentation for the decreased BFR and Registered Nurse notification. 3. Review of the medical record for Patient #4 revealed a 74-year-old female admitted for In-Center Hemodialysis treatments on 01/23/2024. Review of the Physician orders revealed Patient #4’s Blood Flow Rate (BFR) was ordered at 400 and Dialysate Flow Rate (DFR) at 600. Review of the Treatment Flowsheet dated 01/30/2025 revealed Patient #4’s hemodialysis treatment was initiated at 1014 and ended at 1419 (240 minutes). Review of the Flowsheet revealed Patient #4’s BFR average was 308 with no documentation for the decreased BFR and no documentation of the Registered Nurse notification. Review of the Treatment Flowsheet dated 02/04/2025 revealed Patient #4’s hemodialysis treatment was initiated at 0809 and ended at 1304 (283 minutes). Review of the Flowsheet revealed Patient #4’s BFR average was 368 with no documentation for the decreased BFR and no documentation of the Registered Nurse notification. Review of the treatment sheets revealed that Patient #4’s blood flow rate was decreased in 2 of 6 treatments with no notification of the registered nurse. Interview on 02/14/2025 at 1030 with the Manger of Clinical Services revealed the facility’s patient care technicians should notify the nursing staff anytime they increased and/or decreased the patient’s BFR/DFR or were unable to achieve the ordered BFR/DFR. The interview further revealed that the nursing staff should have assessed and documented the reason for the decreased BFR during the patient treatments. The interview confirmed the medical record findings that patient #4 had a decreased BFR in 2 of 6 treatments with no documentation for the decreased BFR and Registered Nurse notification. 4. Review of the medical record for Patient #5 revealed a 42-year-old male admitted for In-Center Hemodialysis treatments on 02/11/2009. Review of the Physician orders revealed Patient #5’s Blood Flow Rate (BFR) was ordered at 450 and Dialysate Flow Rate (DFR) at 600. Review of the Treatment Flowsheet dated 02/08/2025 revealed Patient #5’s hemodialysis treatment was initiated at 0757 and ended at 1242 (264 minutes). Review of the Flowsheet revealed Patient #5’s BFR average was 417, with no documentation for the decreased BFR and no documentation of the Registered Nurse notification. Review of the treatment sheets revealed that Patient #5’s blood flow rate was decreased in 1 of 6 treatment with no notification of the registered nurse. Interview on 02/14/2025 at 1030 with the Manger of Clinical Services revealed the facility’s patient care technicians should notify the nursing staff anytime they increased and/or decreased the patient’s BFR/DFR or were unable to achieve the ordered BFR/DFR. The interview further revealed that the nursing staff should have assessed and documented the reason for the decreased BFR during the patient treatments. The interview confirmed the medical record findings that patient #5 had a decreased BFR in 1 of 6 treatment with no documentation for the decreased BFR and Registered Nurse notification.”
-
Vascular Access - Monitor/Referrals
The inspectors’ words, 552 words
“POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 26622 Based on policy and procedure review, observations, and staff interviews, the facility failed to ensure staff performed skin antisepsis after touching the access sites per policy before cannulation of 2 of 2 Arterio-venous fistula/graft (AVF/AVG) cannulation procedures observed (Station #17, PCT #3 and Station #9, PCT #2). Findings included: Review on 02/11/2025 of the facility policy titled “AV (Arterio-venous) Fistula or Graft Cannulation ...” revised October 2022 revealed “ ... Skin Antiseptic ... Procedure ... 8. Locate and palpate the needle cannulation sites prior to skin preparation. ... 13. Do not palpate insertion site once area has been prepped.” 1. Observation on 02/12/2025 at 1005 in the patient treatment area revealed PCT #3 entered Station #17 and initiated access of an Arterio-venous fistula/graft (AVF/G) for hemodialysis treatment. PCT #3 performed hand hygiene and applied clean gloves. PCT #3 cleansed the arterial and venous access sites with Povidone Iodine pads for 30 seconds. PCT #3 allowed the access sites to dry for 2 minutes before cannulation. Observation revealed PCT #3 touched the arterial and venous access sites with a gloved finger after initial disinfection and failed to re-disinfect each access site prior to cannulation with a needle. Interview on 02/12/2025 at 1015 with PCT #3 revealed that each site should be disinfected for 30 seconds and should not be touched after disinfection. PCT #3 revealed that if the access sites were touched after disinfection, that the sites should be disinfected again prior to needle cannulation. Interview revealed PCT #3 failed to re-disinfect the access sites per facility policy. Interview on 02/12/2025 at 1230 with the Manager of Clinical Services revealed the staff were expected to re-disinfect each access site after contamination and prior to cannulation. Interview revealed the staff failed to follow the facility policy. 2. Observation on 02/12/2025 at 1120 in the patient treatment area revealed PCT #2 entered Station #9 and initiated access of an Arterio-venous fistula/graft (AVF/G) for hemodialysis treatment. PCT #2 performed hand hygiene and applied clean gloves. PCT #2 cleansed the arterial and venous access sites with Povidone Iodine pads for 30 seconds. PCT #2 allowed the access sites to dry for 2 minutes before cannulation. Observation revealed PCT #2 touched the arterial and venous access sites with a gloved finger after initial disinfection and failed to re-disinfect each access site prior to cannulation with a needle. Interview on 02/12/2025 at 1130 with PCT #2 revealed that each site should be disinfected for 30 seconds and should not be touched after disinfection. PCT #2 indicated that if the access sites were touched after disinfection, that the sites should be disinfected again prior to needle cannulation. Interview revealed PCT #2 failed to re-disinfect the access sites per facility policy. Interview on 02/12/2025 at 1230 with the Manager of Clinical Services revealed the staff were expected to re-disinfect each access site after contamination and prior to cannulation. Interview revealed the staff failed to follow the facility policy.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Feb 14, 2025 | Standard inspection | 4 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jan 12, 1996.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and peritoneal dialysis.
- Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
- 25 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
- In CMS’s survey, patients rate its staff 4 of 5.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, worse than expected; emergency department visits, worse than expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- Patients rate it 4 of 5 in CMS’s survey of in-center hemodialysis patients (30 interviews, Oct 18, 2024 to Jul 11, 2025): 82% rated the facility 9 or 10 out of 10.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 2 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | 4 of 5 |
How does it compare nearby?
- No other dialysis facility CMS lists is in Martin County.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing