Hearth Record

Fmc Johnston Dialysis Center Inc.

A dialysis facility in Smithfield, North Carolina 27577

545 East Market Street, Smithfield, North Carolina 27577. (919) 934-9188.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 3 deficiencies in 1 month of the last 36. Last cited Jan 2026. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jan 22, 2026: a standard inspection.

3 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

3 deficiencies in 1 month of the last 36. Last cited Jan 2026. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

3 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jan 22, 2026: standard inspection3 deficiencies
  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 316 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 38766 Based on facility policy review, observation, and interview, the patient care staff failed to prevent cross-contamination by failing to clean and disinfect the Hoyer lift per the facility policy for one of one observation of staff using the Hoyer lift (RN #1) Findings include: Review on 12/30/2025 of the facility’s policy, “Cleaning and Disinfecting the Dialysis Station” published 09/02/2025, revealed, “... General Cleaning... After use, any non-disposable equipment and supplies brought into the dialysis station (ex. stetoscope) must be disinfected with 1:100 bleach, or EPA-registered disinfectant before being removed from the dialysis station...” Observation on 01/20/2026 at 1120 revealed that RN #1 obtained a Hoyer Lift from a holding area to Bay #2. RN #1 and PCT #2 assisted a patient from a wheelchair into the treatment chair via the Hoyer Lift. The observation revealed that RN #1 returned the Hoyer Lift to the holding area near the dialysis machine in station #1. The observation failed to show the staff cleaning and disinfecting the non-disposable equipment before returning to the holding area. An interview on 01/20/2026 at 1130 with RN #1 revealed that the area where the Hoyer Lift was placed, near the dialysis machine in station #1, was clean. The RN reported that the staff planned to disinfect the Hoyer Lift after the patient left for the day, as the patient was the only one using it that day. The RN acknowledged that the Hoyer Lift needed disinfection before being returned to the clean area. The interview confirmed that the cleaning and disinfecting policy was not adhered to.”

    Rule V0122. Standard-level.

  • Ro - Monitor/Alarm/Prevent Use Of Unsafe Water

    The inspectors’ words, 474 words

    “RO-MONITOR/ALARM/PREVENT UNSAFE H20 USE CFR(s): 494.40(a) 5.2.7 Reverse osmosis: alarm/prevent use of unsafe water Refer to RD62:2001, 4.3.7 Reverse osmosis: Reverse osmosis devices shall be equipped with on-line monitors that allow determination of rejection rates and product water conductivity. The product water conductivity monitor should activate audible and visual alarms when the product water conductivity exceeds the preset alarm limit. The audible alarm must be audible in the patient care area when reverse osmosis is the last chemical purification process in the water treatment system. Monitors that measure resistivity or TDS may be used in place of conductivity monitors. 6.2.7 Reverse osmosis: Reverse osmosis systems should be monitored daily using continuous-reading monitors that measure product water conductivity (or total dissolved solids (TDS)). 5.2.7 Reverse osmosis: Refer to RD62:2001, 4.3.7 Reverse osmosis: When a reverse osmosis system is the last chemical purification process in the water treatment system, it [should] include a means to prevent patient exposure to unsafe product water, such as diversion of the product water to drain, in the event of a product water conductivity or rejection alarm. This Standard is not met as evidenced by: 38766 Based on the facility policy review, the facility’s “RO (Reverse Osmosis) Machine Log” review, and staff interviews, the facility staff failed to maintain a daily RO waterlog for two of the two RO waterlogs reviewed. Findings include: Review on 12/30/2025 of the facility’s policy, “Central Reverse Osmosis Water Purification, Operation and Maintenance Policy” published 02/03/2025, revealed “... Policy: Daily Performance Documentation... For RO machines that are not equipped with automated data recording, monitoring of the RO machine’s performance will be completed, documented, and found to be within established operational parameters prior to use of water for dialysis purposes each treatment day...” Review of the daily RO waterlog from 11/01/2025 to 12/31/2025 revealed no documented data on 12/10/2025 for both RO #1 and RO #2 logs. The review indicated that the ROs were not monitored for performance and were not documented as being within operational parameters before patient treatments on 12/10/2025. An interview on 01/21/2026 at 1225 with the Biomedical Technician revealed that the staff should monitor the RO daily before any water usage. The reading of the RO’s performance was to ensure the clinic had safe water for the patients’ safety. The interview also revealed that the Biomedical Technician audited the RO logs monthly, including the log for December 2025. The Technician did not recall noticing the missing data for December 10. The Technician reported that if he had recognized the missing data, he would have emailed the clinic manager immediately about the findings. An interview on 01/21/2026 at 1225 with the ATOM, along with the Biomedical Technician, revealed that the ROs did not have automated data recording, and a daily monitoring documentation was required. The interview confirmed that the policy was not adhered to.”

    Rule V0200. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 384 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 38766 Based on policy review, observations, and staff interviews, the facility staff failed to comply with policies and procedures by not ensuring the patient’s medication syringe was not left unattended in one of two observations (RN #3). Findings included: A review on 01/21/2026 of the facility’s policy, “Medication Preparation and Administration” published 07/07/2025, revealed “...Purpose: To administer medications with the goals of staff and patient safety, optimal therapeutic response, and infection control... Pre-drawing Medications... The pre-drawn medications shall be labeled and must be kept under the preparer’s control or in a locked designated medication storage area or refrigerated, if necessary, until delivery to the appropriate patient for administration...” An observation on 01/21/2026 from 1035 to 1130 of the treatment area revealed that staff attended to the patients during treatments. At or around 1050, RN #3 went to the medication preparation area and removed a kidney basin with multiple pre-drawn syringes from a locked cabinet. The observation revealed that RN #3 placed the basin with the medication syringes on a table in the center of the treatment area. RN #3 obtained two pre-filled syringes from a patient’s station and proceeded with discontinuation of the patient’s treatment. Further observation revealed that RN #3 returned to the table, retrieved two additional syringes from the basin, and proceeded to another patient’s station. The observation revealed that the pre-filled medication syringes were left on the table in the middle of the treatment area unattended while RN #3 provided patient care. An interview on 1105 with RN #3 revealed that the nurse had removed the basin from the medication cabinet to the table because RN #3 needed Heparin (an injectable anticoagulant {blood thinner} used to prevent and treat blood clots in veins, arteries, and lungs, or during medical procedures like dialysis) for two patients. RN #3 acknowledged that she should have removed the patient’s medication from the cabinet one at a time. The interview indicated that RN #3 did not follow the proper process.”

    Rule V0715. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Jan 22, 2026Standard inspection3 deficiencies cited
Nov 5, 2024Complaint inspectionNo deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Sep 21, 1994.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 25 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 4 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 4 of 5 in CMS’s survey of in-center hemodialysis patients (35 interviews, Oct 18, 2024 to Jul 11, 2025): 79% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 54 of 5

How does it compare nearby?

  • Of the 6 dialysis facilities CMS lists in Johnston County, 5 have a star rating from CMS: 1 rated 5 of 5, 1 rated 4 of 5, 3 rated 3 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.