Davita Cross Keys Dialysis

A dialysis facility in Florissant, Missouri 63033

14001 New Halls Ferry Rd #133, Florissant, Missouri 63033. (314) 839-7416.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 14, 2026.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jul 30, 2025: a complaint and standard inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. The last 3 years, to Oct 19, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

Jul 30, 2025: complaint and standard inspection6 deficiencies
  • Esrd Ep Training Program

    The inspectors’ words, 443 words

    “ESRD EP Training Program CFR(s): §494.62(d)(1): Condition for Coverage: (d)(1) Training program. The dialysis facility must do all of the following: (i) Provide initial training in emergency preparedness policies and procedures to all new and existing staff, individuals providing services under arrangement, and volunteers, consistent with their expected roles. (ii) Provide emergency preparedness training at least every 2 years. Staff training must: (iii) Demonstrate staff knowledge of emergency procedures, including informing patients of- (A) What to do; (B) Where to go, including instructions for occasions when the geographic area of the dialysis facility must be evacuated; (C) Whom to contact if an emergency occurs while the patient is not in the dialysis facility. This contact information must include an alternate emergency phone number for the facility for instances when the dialysis facility is unable to receive phone calls due to an emergency situation (unless the facility has the ability to forward calls to a working phone number under such emergency conditions); and (D) How to disconnect themselves from the dialysis machine if an emergency occurs. (iv) Demonstrate that, at a minimum, its patient care staff maintains current CPR certification; and (v) Properly train its nursing staff in the use of emergency equipment and emergency drugs. (vi) Maintain documentation of the training. (vii) If the emergency preparedness policies and procedures are significantly updated, the dialysis facility must conduct training on the updated policies and procedures. This Standard is not met as evidenced by: 17026 Based on record review and staff interview, the facility staff failed to include the social worker and dietician in the facility emergency preparedness training to ensure they were fully prepared in the event of an emergency. This had the potential to effect all patients on dialysis and cause an increase in complications. The facility census was 57. Findings included: 1. Review of the facility emergency preparedness information showed it did not contain documentation that showed the facility social worker or dietician were included in the facility’s emergency preparedness training. 2. During an interview on 7/29/25 at 8:20 AM, the dietician said she has been the dietician at this facility since September of 2024 and she did not recall formal training on emergency preparedness. 3. During an interview on 7/29/25 at 8:45 AM the social worker said she has been the social worker at this facility for seven months and she did not recall formal training on emergency preparedness. 4. During an interview on 7/29/25 at 10:15 AM, the group facility administrator said the dietician and social worker are sometimes at other facilities and staff need to ensure they are at this facility when they conduct emergency preparedness training for staff.”

    Rule E0038. Standard-level. From a complaint.

  • Ic - Aseptic Techniques For Iv Meds

    The inspectors’ words, 197 words

    “IC-ASEPTIC TECHNIQUES FOR IV MEDS CFR(s): 494.30(b)(2) [The facility must-] (2) Ensure that clinical staff demonstrate compliance with current aseptic techniques when dispensing and administering intravenous medications from vials and ampules; and This Standard is not met as evidenced by: 17026 Based on observations and staff interview, the facility staff failed to ensure protein therapy and two containers of test strips were not expired. This had the potential to effect all patients on dialysis and cause an increase in complications. The facility census was 57. Findings included 1. Observation on 7/29/25 at 8:11 AM of the medication refrigerator in the treatment area showed 1000 milliliters of Intradialytic Parenteral Nutrition (IDPN) protein therapy (specialized nutritional therapy for dialysis patients) that expired 6/10/25. 2. Observation on 7/28/25 at 11:28 AM of the water room showed approximately 25 residual test strips that expired 2/19/25. 3. Observation on 7/28/25 at 11:35 AM of the treatment area showed approximately 25 pH (potential of hydrogen) test strips (used to measure how acidic or basic a substance is) that expired 10/31/24. 4. During an interview on 7/29/25 at 11:05 AM, the group facility administrator said staff need to ensure the supplies were not expired.”

    Rule V0143. Standard-level. From a complaint.

  • Ro - Chemical Analysis - Frequency

    The inspectors’ words, 213 words

    “RO-CHEMICAL ANALYSIS-FREQUENCY CFR(s): 494.40(a) 6.2.7 Reverse osmosis: Chemical analysis: frequency Chemical analysis for the contaminants listed in 4.1.1 (Table 1) should be done when the RO system is installed, when membranes are replaced, and at not less than annual intervals thereafter to ensure that the limits specified in 4.1.1 are met (see Table 1). Chemical analyses should be done when seasonal variations in source water suggest worsening quality or when rejection rates fall below 90 %. This Standard is not met as evidenced by: 17026 Based on record review and staff interview, the facility staff failed to conduct an annual chemical analysis of the water in 2024 to determine if the water had any potentially harmful contaminants. This had the potential to effect all patients on dialysis and cause an increase in complications. The facility census was 57. Findings included: 1. Review of the facility’s chemical analysis of the water showed staff did the most recent chemical analysis of water on 10/25/23. The documentation did not show staff completed a chemical analysis of the water in 2024. 2. During an interview on 7/29/25 at 1:25 PM, the biomedical technician said he could not find documentation that showed staff completed a chemical analysis of the water in 2024, but staff should conduct that annually.”

    Rule V0201. Standard-level. From a complaint.

  • Achieve Adequate Clearance

    The inspectors’ words, 240 words

    “POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 17026 Based on record review and staff interview, the facility staff failed to follow the physician order for the blood flow rate or dialysate flow rate for two patients (Patient # 19 and # 42) out of six clinical records reviewed. This had the potential to effect all patients on dialysis and cause an increase in complications. The facility census was 57. Findings included: 1. Review of the treatment flow sheet dated 6/19/25 for Patient # 19 showed the physician directed staff to set the blood flow rate at 350 and the dialysate flow rate at 600, but staff set the blood flow rate at 400 and the dialysate flow rate at 800 for the patient’s dialysis treatment. 2. Review of the treatment flow sheet dated 7/23/25 for Patient # 42 showed the physician directed staff to set the blood flow rate at 400, but staff set the blood flow rate at 350 for the patient’s dialysis treatment. 3. During an interview on 7/29/25 at 11:05 AM, the group facility administrator said staff should follow the physician order for the blood flow rate and dialysate flow rate.”

    Rule V0544. Standard-level. From a complaint.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 265 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 17026 Based on record review and staff interview, the facility staff failed to conduct a pre registered nurse assessment within one hour of a patient starting on dialysis treatment for three patients (Patient # 19, # 42, and # 47) out of six clinical records reviewed. This had the potential to effect all patients on dialysis and cause an increase in complications. The facility census was 57. Findings included: 1. Review of the treatment flow sheet dated 6/24/25 for Patient # 19 showed staff started the patient on dialysis treatment at 12:30 PM but did not conduct the pre registered nurse assessment until 2:32 PM. 2. Review of the treatment flow sheet dated 7/23/25 for Patient # 42 showed staff started the patient on dialysis treatment at 10:39 AM but did not conduct the pre registered nurse assessment until 12:26 PM. 3. Review of the treatment flow sheet dated 7/22/25 for Patient # 47 showed staff started the patient on dialysis treatment at 10:34 AM but did not conduct the pre registered nurse assessment until 12:22 PM. 4. During an interview on 7/29/25 at 11:05 AM, the group facility administrator said staff should conduct the pre registered nurse assessment within one hour of a patient starting on dialysis treatment.”

    Rule V0715. Standard-level. From a complaint.

  • Mr - Protect Patient Records From Loss/Keep Confidential

    The inspectors’ words, 273 words

    “MR-PROTECT PT RECORDS FM LOSS/CONFIDENTIAL CFR(s): 494.170(a) The dialysis facility must- (1)Safeguard patient records against loss, destruction, or unauthorized use; and (2) Keep confidential all information contained in the patient’s record, except when release is authorized pursuant to one of the following: (i) The transfer of the patient to another facility. (ii) Certain exceptions provided for in the law. (iii) Provisions allowed under third party payment contracts. (iv) Approval by the patient. (v) Inspection by authorized agents of the Secretary, as required for the administration of the dialysis program. This Standard is not met as evidenced by: 17026 Based on observations and staff interview, the facility staff failed to ensure the medical records were secured and not accessible to patients or visitors. This had the potential to effect all patients on dialysis and cause an increase in complications. The facility census was 57. Findings included: 1. Observation on 7/28/25 at 11:15 AM showed the door to the treatment area propped open and accessible to anyone that walked in the front door of the facility. 2. Observations on 7/28/25 at 11:40 AM, 12:32 PM, 1:31 PM, and 2:28 PM of the medical records room showed the door to the room propped open. Further observation showed the medical records room adjacent to the dialysis treatment area and accessible to anyone in the dialysis treatment area. 3. Observation on 7/30/25 at 7:24 AM of the medical records room showed the door to the room propped open. 4. During an interview on 7/29/25 at 11:05 AM, the group facility administrator agreed that the medical records need to remain secured and not accessible to any patients or visitors.”

    Rule V0727. Standard-level. From a complaint.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Jul 30, 2025Complaint and standard inspection6 deficiencies cited
Mar 25, 2024Complaint inspectionNo deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Nov 7, 2017.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • 6 deficiencies cited in the last three years came from inspections that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 16 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 36 dialysis facilities CMS lists in Saint Louis County, 35 have a star rating from CMS: 1 rated 5 of 5, 4 rated 4 of 5, 17 rated 3 of 5, 12 rated 2 of 5, 1 rated 1 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 19, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.