Hearth Record

Davita Swope Dialysis

A dialysis facility in Kansas City, Missouri 64130

4407 East 50th Terrace, Kansas City, Missouri 64130. (816) 924-1201.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 5 deficiencies in 2 months of the last 36. Last cited May 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on May 13, 2025: a complaint inspection.

5 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

5 deficiencies in 2 months of the last 36. Last cited May 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

5 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

May 13, 2025: complaint inspection2 deficiencies
  • Ic - Sanitary Environment

    The inspectors’ words, 547 words

    “IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 36473 Based on observation, interview and policy review, the facility failed to ensure staff provided and maintained a clean environment free from potential contaminants when the staff failed to maintain: - The four sharps container roller carts of four observed located on the treatment floor, free of rust (a reddish or yellowish-brown flaky coating formed on iron or steel that had the potential to harbor dangerous bacteria). - The floors around and behind the patient stations free of dirt. - Two wall boxes of 19 observed free of discoloration and dirt. - One patient chair of 19 observed free of approximately a one foot rip with exposed foam (a porous material that had the potential to attract bacteria). - The treatment floor free of one capped needle. - The patient restroom (located off the treatment floor) free of dirt around the base of toilet. - The chlorine testing cart in the water room free of dirt. - The eye wash emergency station and sink in the water room free of rust and dirt. These failed practices had the potential for increased risk of cross-contamination and transmission of pathogens to all patients and staff. The in-center hemodialysis (the process of purifying the blood of persons whose kidneys were not working) patient census was 103. Findings included: TREATMENT FLOOR 1.Observations on 5/12/25 between 3:00 PM - 5:00 PM and on 5/13/25 between 8:30 AM - 1:00 PM showed four sharps container roller carts rusted at Station #6, Station #9, Station #12 and Station #15. 2.Observation on 5/12/25 between 3:00 PM - 5:00 PM, showed the patient treatment floors around and behind the patient hemodialysis machines were unclean. 3. Observation on 5/12/25 at 4:15 PM, showed at Station #15 and Station #19 discolored wall boxes. 4. Observation on 5/12/25 at 4:20 PM, showed at Station #14 one patient chair ripped in the center of the seat exposing foam material and approximately one foot long in length. 5. Observation on 5/12/25 at 4:00 PM, in front of Station #14 on the floor, one capped needle. 6. Observation on 5/12/25 at 4:30 PM, off the patient treatment floor, an unclean floor around the toilet in the patient’s restroom. 7. During an interview on 5/13/25 at 11:00 AM, Staff A, Facility Administrator, stated the facility’s cleaning company failed to clean on the weekends. 8. Review of the facility’s policy titled, “Infection Control for Dialysis Facilities,” last reviewed on 4/2023, showed the direction for staff to minimize the spread of infections or bloodborne pathogens in the facility environment. WATER ROOM 9. Observation on 5/12/25 at 3:20 PM, in the water treatment room, showed: - The chlorine testing cart unclean. - One sink next to the emergency eyewash station with two large rusted screws and two rusted spacers. - The holder for the emergency eyewash station was unclean and rusted. 10. During an interview on 5/13/25 at 11:00 AM, Staff A, Facility Administrator, stated the biomed technician cleans the water room and the facility staff should have kept the chlorine testing cart clean.”

    Rule V0111. Standard-level. From a complaint.

  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 240 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 36473 Based on observation, interview and policy review, the facility failed to ensure that staff used proper aseptic (method that targets practices and procedures to reduce contamination) technique when performing Central Venous Catheter (CVC, a line placed in a large vein for hemodialysis [the process of purifying the blood of persons whose kidneys were not working] dressing changes performed for one patient (#2) of two observed. These failures had the potential for cross-contamination and the spread of infections to patients and staff. The in-center hemodialysis census was 103. Findings included: 1.Observation on 1/13/25 at 11:40 AM, Staff C, Certified Clinical Hemodialysis Technician (CCHT), during a CVC dressing change, showed Staff C failed to adhere to aseptic technique during the CVC site cleaning with a Chloraprep (a swabstick used to disinfect the skin and prevent infections) by touching the patient’s contaminated shirt and necklace. 2.During an interview with Staff A, Facility Administrator, stated staff should follow the facility’s policy and adhere to aseptic technique. 3. Review of the facility’s policy titled, “Central Venous Catheter with Clearguard Antimicrobial End Caps Procedure,” last reviewed on 4/2025, showed the direction for staff to perform a CVC dressing change using the aseptic technique.”

    Rule V0113. Standard-level. From a complaint.

Jan 15, 2025: standard inspection3 deficiencies
  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 300 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 17026 Based on observations and staff interview, the facility staff failed to fully disinfect the dialysis station during three (station # 12, # 17, and # 19) observations and failed to wait until the patient left the dialysis station to start station disinfection during one (station # 18) observation. This had the potential to effect all patients on dialysis and cause an increase in cross contamination risk. The facility had 19 dialysis stations and the census was 100. Findings included: 1. Observation on 1/14/25 at 10:27 AM showed Patient Care Technician (PCT) (R) disinfected the dialysis machine at station # 18 while the patient remained in the dialysis chair. Staff did not wait until the patient left the station to start station disinfection. 2. Observation on 1/13/25 at 12:24 PM showed PCT (D) disinfected station # 17 but did not disinfect the chase wall (wall that houses the water distribution system) behind the station. 3. Observation on 1/13/25 at 1:06 PM showed PCT (A) disinfected station # 19 but did not disinfect the chase wall behind the station. 4. Observation on 1/13/25 at 1:18 PM showed PCT (C) disinfected station # 12 but did not disinfect the intravenous fluid hooks or the chase wall behind the station. 5. During an interview on 1/14/25 at 10:55 AM, the facility administrator said staff should wait until the patient leaves the dialysis station to start station disinfection, and staff should disinfect the entire station during station disinfection.”

    Rule V0122. Standard-level.

  • Appropriateness Of Dialysis Rx

    The inspectors’ words, 293 words

    “PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 17026 Based on record review and staff interview, the facility staff failed to follow the physician order for the blood flow rate during dialysis treatment for three (Patient # 14, # 74, and # 76) out of 10 clinical records reviewed. This had the potential to effect all patients on dialysis and cause an increase in complications. The facility census was 100. Findings included: 1. Review of the treatment flow sheet dated 1/3/25 for Patient # 14 showed the physician directed staff to set the blood flow rate at 400 during the patient’s dialysis treatment. Further review of the treatment flow sheet showed staff set the blood flow rate at 300 during the patient’s dialysis treatment. 2. Review of the treatment flow sheet dated 1/9/25 for Patient # 74 showed the physician directed staff to set the blood flow rate at 450 during the patient’s dialysis treatment. Further review of the treatment flow sheet showed staff set the blood flow rate at 400 during the patient’s dialysis treatment. 3. Review of the treatment flow sheet dated 1/11/25 for Patient # 76 showed the physician directed staff to set the blood flow rate at 300 during the patient’s dialysis treatment. Further review of the treatment flow sheet showed staff set the blood flow rate at 350 during the patient’s dialysis treatment. 4. During an interview on 1/14/25 at 10:55 AM, the facility administrator said staff should follow the physician order for the blood flow rate, or document the reason for not following the order and document physician notification.”

    Rule V0503. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 294 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 17026 Based on record review and staff interview, the facility staff failed to document a reason for stopping dialysis treatment early for two patients (Patient # 88 and # 91) out of 10 clinical records reviewed. This had the potential to effect all patients on dialysis and cause an increase in complications. The facility census was 100. Findings included: 1. Review of the treatment flow sheet 1/10/25 for Patient # 91 showed the physician directed staff to provide the patient with four hours of dialysis treatment. Further review of the treatment flow sheet sheet showed staff stopped dialysis treatment 40 minutes early without documenting a reason why. 2. Review of the treatment flow sheet dated 1/8/25 for Patient # 91 showed the physician directed staff to provide the patient with four hours of dialysis treatment. Further review of the treatment flow sheet sheet showed staff stopped dialysis treatment 30 minutes early without documenting a reason why. 3. Review of the treatment flow sheet dated 1/3/25 for Patient # 88 showed the physician directed staff to provide the patient with three hours of dialysis treatment. Further review of the treatment flow sheet sheet showed staff stopped dialysis treatment 19 minutes early without documenting a reason why. 4. During an interview on 1/14/25 at 10:55 AM, the facility administrator said staff should document a reason for stopping dialysis treatment early or have the patient sign an against medical advice form.”

    Rule V0715. Standard-level.

All 3 inspections in the last three years
Inspections on record
DateVisitWhat the record says
May 13, 2025Complaint inspection2 deficiencies cited
Mar 10, 2025Complaint inspectionNo deficiencies cited
Jan 15, 2025Standard inspection3 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Oct 19, 2012.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • 2 deficiencies cited in the last three years came from inspections that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 19 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 2 of 5 in CMS’s survey of in-center hemodialysis patients (49 interviews, Oct 18, 2024 to Jul 11, 2025): 53% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 52 of 5

How does it compare nearby?

  • Of the 19 dialysis facilities CMS lists in Jackson County, 17 have a star rating from CMS: 4 rated 4 of 5, 8 rated 3 of 5, 4 rated 2 of 5, 1 rated 1 of 5.
  • CMS rates this one 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.