Fresenius Medical Care of Plymouth Cordage
A dialysis facility in Plymouth, Massachusetts 02360
10 Cordage Park Circle, Suite 213, Plymouth, Massachusetts 02360. (508) 732-9272.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 4of 5 CMS’s star rating
- 4of 5 patient survey rating
- 7 deficiencies cited in the last three years
- 16 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Mar 26, 2025: a standard inspection.
7 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
7 deficiencies in 1 month of the last 36. Last cited Mar 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Mar 26, 2025: standard inspection7 deficiencies
-
Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts
The inspectors’ words, 406 words
“IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 44223 Based on observation and staff interview, the facility failed to ensure that proper infection control practices were followed when personal protective equipment (PPE) came in contact with both clean and dirty areas on the dialysis treatment floor. Findings include: During an observation of the treatment floor on 3/25/25 at 11:00 A.M., the surveyor observed multiple hooks, along the wall, outside of the Clinic Manager’s (CM) office. There were 11 faceshields and 2 gowns hanging on the hooks. The faceshields were overlapping and stacked on each other, causing concern for potential cross contamination. The 2 gowns, which had been worn by staff on the treatment floor, were overlapping, causing concern for potential cross contamination. During an observation of the treatment floor on 3/26/25 at 7:45 A.M., the surveyor observed multiple hooks along the wall outside the CM’s office. There were 11 faceshields and 3 gowns observed hanging from the hooks. The shields and gowns were touching each other, causing concern for potential cross contamination. There was a stethoscope hanging on the hook, under one of the gown, causing concern for cross contamination. During an observation of the treatment floor outside of the isolation room on 3/26/25 at 2:00 P.M., the surveyor observed a stethoscope hanging on a hook and the end was touching the fire extinguisher located below the hook. During an interview on 3/26/25 at 2:00 P.M., the CM said that PPE should be separated when hung on the hooks. She said there is a special box, located by the exit door to the lobby where staff should store their stethoscopes.”
-
Ic - Oversight: Monitor Activities & Implement Policies
The inspectors’ words, 298 words
“IC-O-SIGHT-MONITOR ACTIVITY/IMPLEMENT P&P CFR(s): 494.30(b)(1) The facility must- (1) Monitor and implement biohazard and infection control policies and activities within the dialysis unit; This Standard is not met as evidenced by: 27189 Based on observation, interview, and policy review, the facility failed to ensure that 1 of 2 staff (Registered Nurse [RN] #6), follow proper infection control practices during the initiation of dialysis for 1 of 2 patients (Patient #1) with an Arteriovenous Fistula/Graft (AVF/G), from a total sample of 8 patients. Findings include: Review of the facility policy titled, Assessment and Cannulation, dated 5/6/24, included but was not limited to the following: *Perform skin antisepsis on one site at a time, allow it to dry and then cannulate. Do not touch cannulation sites after skin disinfection. For Patient #1, RN #6 failed to disinfect the cannulation sites of the patient’s AVF/G, after she palpated the access sites, which increased the potential risk for infection. Patient #1 was admitted to the facility in January 2025 with the diagnosis of End Stage Renal Disease (ESRD), requiring hemodialysis three times a week. During an observation on the treatment floor on 3/25/2025 at 9:30 A.M., the surveyor observed RN #6 initiate dialysis treatment for Patient #1 with an AVF. RN #6 listened and palpated the fistula, then disinfected the upper and lower access of the AVF with two separate alcohol prep pads (one for each access site). RN #6 then palpated the access sites again, contaminating the site. Without performing disinfection of the access sites, RN #6 cannulated both sites. RN #6 failed to disinfect the access sites after she contaminated the area. During an interview on 3/25/25 at 9:45 A.M., RN #6 said she should have disinfected the AVF access sites after she palpated the area, just prior to cannulation.”
-
Ic - Staff Education Re Catheters/Catheter Care
The inspectors’ words, 409 words
“IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 10249 Based on observation, staff interview, and policy review, the facility failed to ensure 1 of 2 staff observed (Registered Nurse [RN] #1) implemented adequate infection control measures during termination of treatment for 1 of 2 patients (#8) with a Central Venous Catheter (CVC), out of a total sample of 8 patients. Finding include: Review of the facility policy titled, Termination of Treatment Using a Central Venous Catheter and Optiflux single Use Ebeam Dialyzer, published 11/4/24, included the following: *Prior to termination: *Preparation: *Don own gown and full face shield with mask (or protective eyewear with full side shields and mask). Place mask on patient, perform hand hygiene, then don gloves. During an observation of the treatment floor on 3/25/25 at 9:30 A.M., the surveyor observed RN #1 terminate the dialysis treatment for Patient #8 who had a CVC for dialysis access. Patient #8 wore a mask below his/her nose, only covering his/her mouth, throughout the whole process of termination of dialysis treatment. RN #1 failed to encourage Patient #8 to adjust his/her face mask to cover his/her nose and mouth while she performed termination of dialysis treatment with CVC, including disconnecting the blood lines. During an interview on 3/25/25 at 9:35 A.M., RN #1 said she “totally missed that” and should have made sure that Patient #8’s mask was covering his/her nose and mouth. During an interview on 3/26/25 at 1:00 P.M., The Clinic Manager said the staff member had told her about the observation and the patient’s mask should have covered their nose and mouth during the termination of the treatment.”
-
Pe - Building - Constructed/Maintained To Ensure Safety
The inspectors’ words, 270 words
“PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 44223 Based on observation and staff interview, the facility failed to maintain a safe environment for staff in the water and storage supply room. Findings include: On 3/25/25 at 8:05 A.M., during the flash tour of the water and supply storage room, the surveyor observed the following: *The storage room floor was cement and gray in color. In five areas the floor was observed to have cracks and broken pieces. These cracks caused divots in the flooring causing potential risk for tripping. *In front of the storage room delivery door, the floor had two large circular broken areas, where the cement was missing, exposing the plywood underneath, causing potential risk for tripping. During an interview on 3/26/25 at 8:30 A.M., the Biomedical Technician (Biomed) said he has tried to patch the broken areas on the floor but it does not stay. He says he has to repatch the areas every three months or so. The Biomed said that the floor has been discussed in the past about what can be done to fix it but he is not really sure if there is a set plan in place to fix or replace the floor. During an interview on 3/26/25 at 2:30 P.M., the Director of Operations said he is aware of the floor in the water storage area, but had not developed a plan as to when the floor would be fixed.”
-
Frequency Reassessment - Unstable - Monthly
The inspectors’ words, 387 words
“PA-FREQUENCY REASSESSMENT-UNSTABLE Q MO CFR(s): 494.80(d)(2) In accordance with the standards specified in paragraphs (a)(1) through (a)(13) of this section, a comprehensive reassessment of each patient and a revision of the plan of care must be conducted- At least monthly for unstable patients including, but not limited to, patients with the following: (i) Extended or frequent hospitalizations; (ii) Marked deterioration in health status; (iii) Significant change in psychosocial needs; or (iv) Concurrent poor nutritional status, unmanaged anemia and inadequate dialysis. This Standard is not met as evidenced by: 10249 Based on record review, interview, facility report review, and policy review, the facility failed to ensure an unstable comprehensive re-assessment and revision of the plan of care was conducted after an extended hospitalization stay greater than 15 days, for 1 of 7 applicable patients (#2), out of a total sample of 8 patients. Findings Include: Review of the facility policy titled, Comprehensive Interdisciplinary Assessment and Plan of Care, revised 7/3/23, indicated the following: *Unstable patients must be reassessed by the IDT (Interdisciplinary Team) monthly. Monthly reassessment and any POC updates related to the reason the patient is considered “unstable” must be documented until the issues have been resolved or the IDT (including the patient if possible) determines that the conditions is chronic. *The following are unstable criteria: *Extended or frequent hospitalizations: *a. Hospitalization of more that 15 days with discharge occurring within the last 30 days, or *b. More than 3 admissions in the past 30 days Patient #2 was admitted in November 2021 with a diagnosis of End Stage Renal Disease, requiring dialysis three times a week. Review of the clinical record indicated that Patient #2 had an annual Comprehensive Assessment completed in April 2024, with a plan of care developed based on that assessment. Further review of the clinical record, and Absence and Hospitalization report, indicated that Patient #2 had been hospitalized from 2/3/25 through 2/21/25, for a total of 18 days, for a diagnoses of osteomyelitis. During an interview on 3/26/25 at 9:40 A.M., the Clinic Manager said when Patient #2 returned to the clinic after the hospitalization, she discussed the status with the Medical Director who determined that the patient was stable, so the team did not reassess. She also said there is no documentation of the discussion she had with the Medical Director.”
-
Qapi Indicator - Infection Control - Trend/Plan/Act
The inspectors’ words, 333 words
“QAPI-INDICATOR-INF CONT-TREND/PLAN/ACT CFR(s): 494.110(a)(2)(ix) The program must include, but not be limited to, the following: (ix) Infection control; with respect to this component the facility must- (A) Analyze and document the incidence of infection to identify trends and establish baseline information on infection incidence; (B) Develop recommendations and action plans to minimize infection transmission, promote immunization; and (C) Take actions to reduce future incidents. This Standard is not met as evidenced by: 10249 Based on review of the facility Quality Assessment Performance Improvement (QAPI) committee meeting minutes, review of the monthly infection control audits, interview, and policy review, the facility failed to ensure monthly visual infection control audits were completed for arteriovenous fistula and graft (AVF/AVG) disinfection compliance, to ensure they could be consistently measured, analyzed, and a plan developed based on the results of monthly infection control audits. Findings include: Review of the facility policy titled, Quality Assessment and Performance Improvement Program, dated 11/4/24, indicated the following: *The QAPI Committee will monitor data/information, prioritize areas for improvement, determine potential root cause analysis, develop, implement, evaluate and revise action plans that results in sustainable improvements in patients care. *Elements to be reviewed will include: -Patient care outcomes. -Infection surveillance. -Patient safety. -Staff training and education. *An effective and successful review of QAPI meeting and program activities will include: -Analysis of QAPI trending tool. -Review of the results of required self-audits. During the survey, 1 of 2 staff (Registered Nurse [RN] #6) observed had an infection control breach during initiation of hemodialysis treatment for a patient with an AVF. RN #6 failed to disinfect each access site after palpating with gloved hands, per facility policy. Review of the facility monthly visual infection control audit checklist for 12 months (March 2024 through February 2024) failed to include visual audits of care for patients with Arterio-Venous Fistula (AVF) and Arterio-Venous Graft (AVG) access. During an interview on 3/26/25 at 1:00 P.M., the Clinic Manager said they do not monitor AVF/G during monthly infection control visual audits.”
-
Md Resp - Ensure All Adhere To P&P
The inspectors’ words, 359 words
“MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 27189 Based on record review, interview, and policy review, the Medical Director failed to ensure that staff followed the policy related to reversal of Central Venous Catheter (CVC) lines for 1 patient (#5), in a total sample of 8 patients. Findings include: Review of the facility policy titled, Reversal of Central Venous Catheter Lines, dated 2/5/2024, indicated but was not limited to the following: *The RN is responsible for assessing and performing any trouble-shooting procedures including reversal of CVC lines. *Reversal of CVC lines requires the following documentation in the patient’s medical recorded: *Provider order with frequency (each treatment, x 1, etc.) entered in the patient medical record. *Reason for line reversal. *Action of reversal in the treatment record. *Evaluation of catheter function and future need for vascular referral. For Patient #5, the staff failed to notify the physician of the CVC lines needing to be reversed, document the reason why, and obtain a physician’s order to reverse the lines, per facility policy. Patient #5 was admitted to the facility in March 2017 with a diagnosis of End Stage Renal Disease (ESRD), requiring hemodialysis. Patient #5 was receiving dialysis treatment via a CVC. Review of the dialysis treatment flowsheets, dated 3/6/25 through 3/25/25, indicated that for 8 of 9 treatments the CVC lines were reversed on 3/6/2025, 3/11/2025, 3/13/2025, 3/15/2025, 3/18/2025, 3/20/2025, 3/22/2025, and 3/25/2025. Review of the clinical record, and dialysis treatment flowsheet, indicated there was no documented evidence that nursing had notified the physician and obtained an order to reverse the lines. During an interview on 3/26/25 at 3:00 P.M., the Clinic Manager (CM) said the nursing staff should notify the physician if the CVC lines needed to be reversed, document the reason why, and obtain a physician’s order to reverse the lines. She also said staff failed to do this.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Mar 26, 2025 | Standard inspection | 7 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jan 20, 2006.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
- Doesn’t offer a shift starting at 5 p.m. or later.
- 16 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
- In CMS’s survey, patients rate its staff 5 of 5.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 4 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- Patients rate it 4 of 5 in CMS’s survey of in-center hemodialysis patients (32 interviews, Oct 18, 2024 to Jul 11, 2025): 85% rated the facility 9 or 10 out of 10.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 4 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | 4 of 5 |
How does it compare nearby?
- Of the 4 dialysis facilities CMS lists in Plymouth County, 4 have a star rating from CMS: 1 rated 5 of 5, 2 rated 4 of 5, 1 rated 3 of 5.
- CMS rates this one 4 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Brockton Dialysis Center, LLC | 4 |
| Brockton Regional Kidney Center | 5 |
| Fresenius Medical Care of Wareham | 3 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.