Fmc - Paintsville

A dialysis facility in Paintsville, Kentucky 41240

620 Jefferson Ave, Paintsville, Kentucky 41240. (606) 789-2278.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 3 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on May 8, 2025: a standard inspection.

3 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

3 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

3 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

May 8, 2025: standard inspection3 deficiencies
  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 410 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 35949 Based on observation, interview, and facility policy review, the facility failed to ensure environmental surfaces in the dialysis treatment stations were disinfected at the end of each dialysis treatment during 2 of 2 observations. This failure had the potential to affect 39 patients who received dialysis treatments at the facility. Findings included: A facility policy titled, “Cleaning and Disinfecting the Dialysis Station,” dated 09/05/2023, indicated, “The Centers for Medicare and Medicaid Services (CMS) has regulations that in order to prevent cross contamination, a dialysis station must be cleaned and disinfected between dialysis patients. The chair and dialysis equipment are used by multiple patients during a treatment day [sic] and it is critical that these items be thoroughly cleaned and disinfected between uses.” The section of the policy titled “Definition” revealed that a “Dialysis Station” was defined as an “Area including the dialysis machine, chair/bed and other reusable equipment or supplies utilized during dialysis treatment, patient training, and/or patient clinic visits. Equipment in the dialysis station may include (but is not limited to) the following: - Dialysis machine/cycler and attachments such as IV [intravenous] pole, BP [blood pressure] cuff and hand sanitizer/holder, organizer - Chair/bed - [Brand name of water and dialysate preparation system] - Individual television and remote.” An observation of the hemodialysis treatment area on 05/06/2025 at 11:12 AM, revealed Registered Nurse (RN) #1 failed to disinfect the sanitizer bottle and the bracket attached to the side of the dialysis machine while disinfecting Station 10. An observation of the hemodialysis treatment area on 05/06/2025 at 11:45 AM, revealed Certified Clinical Hemodialysis Technician (CCHT) #3 failed to disinfect the sanitizer bottle and the bracket attached to the side of the dialysis machine while disinfecting Station 2. During concurrent interviews on 05/06/2025 at 11:50 AM, RN #1 and CCHT #3 acknowledged they were trained and expected to disinfect all surfaces in the treatment stations after each dialysis treatment. During an interview on 05/06/2025 at 11:55 AM, the Clinical Manager (CM) confirmed staff were expected to disinfect all surfaces in the dialysis treatment stations after each dialysis treatment, including the sanitizer bottles and the brackets”

    Rule V0122. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 836 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 35949 Based on observation, interview, facility policy review, and review of a manufacturer’s instructions for use (IFU), the facility failed to maintain arterial drip chamber fluid levels at approximately 90% full and venous drip chamber fluid levels at approximately 70% full during 3 of 3 observations. This failure had the potential to affect 39 patients who received dialysis treatments at the facility. Findings included: A facility policy titled, “Initiation of Treatment Using an Arteriovenous Graft or Fistula and [Brand name] Dialyzer,” dated 05/05/2025, revealed the section titled, “Final Machine Verification,” included, “Prior to starting the blood pump, verify the following: 1. All connections are secure. 2. Dialysate lines are attached properly to the dialyzer. 3. There is at least 300 ml [milliliters] of saline in the saline bag and the saline line is double clamped. 4. Any unused administration lines are clamped. 5. The arterial chamber is 85-95% full, and venous chamber is 65-75% full. 6. Arterial and venous monitoring transducers are securely connected, not wet with saline, and the transducer clamps are open. 7. Blood pump segment is threaded through the pump properly. 8. Venous drip chamber is correctly positioned in its housing and venous bloodline is threaded through [sic] venous occluding clamp. 9. No kinks or bends are evident in any of the tubing. 10. No air is noted in the dialyzer or bloodlines.” A facility policy titled, “Initiation of Treatment Using a Central Venous Catheter (CVC) and [Brand name] Dialyzer,” dated 05/05/2025, revealed the section titled, “Final Machine Verification,” included, “Prior to starting the blood pump, verify the following: 1. All connections are secure. 2. Dialysate lines are attached properly to the dialyzer. 3. There is at least 300 ml [milliliters] of saline in the saline bag and the saline line is double-clamped. 4. Any unused administration lines are clamped. 5. The arterial chamber is 85-95% full, and venous chamber is 65-75% full. 6. Arterial and venous monitoring transducers are securely connected, not wet with saline, and the transducer clamps are open. 7. Blood pump segment is threaded through the pump properly. 8. Venous drip chamber is correctly positioned in its housing and venous bloodline is threaded through (sic) venous occluding clamp. 9. No kinks or bends are evident in any of the tubing. 10. No air is noted in the dialyzer or bloodlines.” An undated “Hemodialysis Blood Tubing Set with Attached Priming Set, Transducer Protectors and Integrated Crit-Line Technology Catalog Number: 03-2722-9C and 03-2742-9C Instructions For Use,” revealed the section titled, “Dialysis Treatment Precautions,” included, “2. During Treatment: a. Periodically check the extracorporeal circuit for any evidence of possible separation or leaks. b. Do not allow the access or bloodline connections to be covered with a blanket or clothing during treatment. c. Maintain fluid level in arterial chamber at approximately 90% full and venous chamber at approximately 70% full. Levels may rise or drop during the treatment due to changes in pressure or flow rate. Readjust levels as needed. Air leaks will also cause the chamber levels to fluctuate.” An observation of the hemodialysis treatment area on 05/05/2025 at 10:17 AM, revealed the arterial drip chamber fluid levels were less than (<) 90% full in Station 10 and Station 11, and the venous drip chamber fluid levels were greater than (>) 70% full in Stations 2, 4, 8, 10, 11, and 14. An observation of the hemodialysis treatment area on 05/7/2025 at 8:57 AM, revealed the arterial drip chamber fluid levels were < 90% full in Stations 1, 3, 4, 5, 9, 10, 12, 13, and 16, and the venous drip chamber fluid levels were > 70% full in Stations 1, 2, 3, 4, 5, 7, 9, 10, 12, 13, and 16. An observation of the hemodialysis treatment area on 05/07/2025 at 9:07 AM, revealed the arterial drip chamber fluid levels were < 90% full in Stations 1, 3, 4, 5, 12, 13, and 16, and the venous drip chamber fluid levels were > 70% full in Stations 1, 2, 3, 4, 5, 7, 9, 10, 12, 13, and 16. During an interview on 05/07/2025 at 9:17 AM, the Clinical Manager (CM) reviewed the manufacturer’s IFU and stated the arterial and venous drip chamber fluid levels were not maintained according to the IFU. During an interview on 05/07/2025 at 9:25 AM, Certified Clinical Hemodialysis Technician (CCHT) #3 stated the arterial drip chamber should be “90% or above the line” and the venous drip chamber fluid levels should be “above the line.” CCHT #3 stated the drip chambers were not maintained according to the manufacturer’s IFU. During an interview on 05/07/2025 at 1:25 PM, Registered Nurse (RN) #1 stated she was trained to maintain the drip chamber fluid levels according to the manufacturer’s IFU.”

    Rule V0403. Standard-level.

  • Appropriateness Of Dialysis Rx

    The inspectors’ words, 1,265 words

    “PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 35949 Based on interview, record review, and facility policy review, the facility failed to follow dialysis prescriptions for 5 (Patients #1, #2, #3, #4, and #5) of 5 sampled residents who received dialysis treatments at the facility. Findings included: A facility policy titled, “Patient Assessment and Monitoring,” dated 05/01/2023, indicated, “3. Machine Parameters and Extracorporeal Circuit - Check machine settings and measurements: -Check prescribed blood flow is being achieved or reason is documented in medical record if unable to meet prescribed blood flow.” 1. Patient #1’s “Treatment Sheet for Facility,” dated 04/26/2025, revealed a prescribed blood flow rate (BFR) of 400 milliliters per minute (mL/min). The treatment sheet revealed Patient #1’s BFR was documented as 450 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. Patient #1’s “Treatment Sheet for Facility,” dated 04/29/2025, revealed a prescribed BFR of 400 mL/min. The treatment sheet revealed Patient #1’s BFR was documented as 450 mL/min from 1:05 PM until the treatment was terminated at 4:32 PM. The treatment sheet revealed there was no rationale documented as to why the prescribed BFR was not achieved. Patient #1’s “Treatment Sheet for Facility,” dated 05/01/2025, revealed a prescribed BFR of 450 mL/min. The treatment sheet revealed Patient #1’s BFR was documented as 400 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. Patient #1’s “Treatment Sheet for Facility,” dated 05/03/2025, revealed a prescribed BFR of 450 mL/min. The treatment sheet revealed Patient #1’s BFR was documented between 300 mL/min and 350 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. During an interview on 05/07/2025 at 1:04 PM, Certified Clinical Hemodialysis Technician (CHHT) #3 stated she was expected to “write down” a reason the prescribed blood flow rate was not achieved. During an interview on 05/07/2025 at 1:25 PM, Registered Nurse (RN) #1 stated she was expected to “document why” a prescribed blood flow rate was not achieved. During an interview on 05/07/2025 at 3:30 PM, the Clinical Manager (CM) confirmed staff were expected and trained to document a reason when the prescribed blood flow rate was not achieved. 2. Patient #2’s “Treatment Sheet for Facility,” dated 04/25/2025, revealed a blood flow rate (BFR) of 450 milliliters per min (mL/min). The treatment sheet revealed Patient #2’s BFR was documented as 400 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. During an interview on 05/07/2025 at 1:04 PM, Certified Clinical Hemodialysis Technician (CHHT) #3 stated she was expected to “write down” a reason the prescribed blood flow rate was not achieved. During an interview on 05/07/2025 at 1:25 PM, Registered Nurse (RN) #1 stated she was expected to “document why” a prescribed blood flow rate was not achieved. During an interview on 05/07/2025 at 3:30 PM, the Clinical Manager (CM) confirmed staff were expected and trained to document a reason when the prescribed blood flow rate was not achieved. 3. Patient #3’s “Treatment Sheet for Facility,” dated 04/19/2025, revealed a prescribed blood flow rate (BFR) of 400 milliliters per minute (mL/min). The treatment sheet revealed Patient #3’s BFR was documented as 315 mL/min from 7:32 AM until the treatment was terminated at 10:05 AM. The treatment sheet revealed there was no rationale documented as to why the prescribed BFR was not achieved. During an interview on 05/07/2025 at 1:04 PM, Certified Clinical Hemodialysis Technician (CHHT) #3 stated she was expected to “write down” a reason the prescribed blood flow rate was not achieved. During an interview on 05/07/2025 at 1:25 PM, Registered Nurse (RN) #1 stated she was expected to “document why” a prescribed blood flow rate was not achieved. During an interview on 05/07/2025 at 3:30 PM, the Clinical Manager (CM) confirmed staff were expected and trained to document a reason when the prescribed blood flow rate was not achieved. 4. Patient #4’s “Treatment Sheet for Facility,” dated 04/16/2025, revealed a prescribed blood flow rate (BFR) of 450 milliliters per minute (mL/min). The treatment sheet revealed Patient #4’s BFR was documented as 300 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. Patient #4’s “Treatment Sheet for Facility,” dated 04/18/2025, revealed a prescribed BFR of 450 mL/min. The treatment sheet revealed Patient #4’s BFR was documented as 350 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. Patient #4’s “Treatment Sheet for Facility,” dated 04/21/2025, revealed a prescribed BFR of 450 mL/min. The treatment sheet revealed Patient #4’s BFR was documented as 350 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. Patient #4’s “Treatment Sheet for Facility,” dated 04/23/2025, revealed a prescribed BFR of 450 mL/min. The treatment sheet revealed Patient #4’s BFR was documented as 350 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. Patient #4’s “Treatment Sheet for Facility,” dated 04/25/2025, revealed a prescribed BFR of 450 mL/min. The treatment sheet revealed Patient #4’s BFR was documented as 300 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. During an interview on 05/07/2025 at 1:04 PM, Certified Clinical Hemodialysis Technician (CHHT) #3 stated she was expected to “write down” a reason the prescribed blood flow rate was not achieved. During an interview on 05/07/2025 at 1:25 PM, Registered Nurse (RN) #1 stated she was expected to “document why” a prescribed blood flow rate was not achieved. During an interview on 05/07/2025 at 3:30 PM, the Clinical Manager (CM) confirmed staff were expected and trained to document a reason when the prescribed blood flow rate was not achieved. 5. Patient #5’s “Treatment Sheet for Facility,” dated 04/16/2025, revealed a prescribed blood flow rate (BFR) of 400 milliliters per minute (mL/min). The treatment sheet revealed Patient #5’s BFR was documented as 350 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. Patient #5’s “Treatment Sheet for Facility,” dated 04/23/2025, revealed a prescribed BFR of 400 mL/min. The treatment sheet revealed Patient #5’s BFR was documented as 350 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. Patient #5’s “Treatment Sheet for Facility,” dated 04/28/2025, revealed a prescribed BFR of 400 mL/min. The treatment sheet revealed Patient #5’s BFR was documented as 350 mL/min during the entire treatment, and there was no rationale documented as to why the prescribed BFR was not achieved. During an interview on 05/07/2025 at 1:04 PM, Certified Clinical Hemodialysis Technician (CHHT) #3 stated she was expected to “write down” a reason the prescribed blood flow rate was not achieved. During an interview on 05/07/2025 at 1:25 PM, Registered Nurse (RN) #1 stated she was expected to “document why” a prescribed blood flow rate was not achieved. During an interview on 05/07/2025 at 3:30 PM, the Clinical Manager (CM) confirmed staff were expected and trained to document a reason when the prescribed blood flow rate was not achieved.”

    Rule V0503. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
May 8, 2025Standard inspection3 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Oct 7, 2002.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 16 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • No other dialysis facility CMS lists is in Johnson County.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.