Davita Whitewater Valley Dialysis

A dialysis facility in Richmond, Indiana 47374

2302 Chester Blvd, Richmond, Indiana 47374. (765) 935-5128.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.

The last 24 months 5 deficiencies in 1 month of the last 36. Last cited Jun 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jun 23, 2025: a standard inspection.

5 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

5 deficiencies in 1 month of the last 36. Last cited Jun 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

5 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jun 23, 2025: standard inspection5 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 256 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 44230 Based on observation, record review, and interview, staff failed to ensure adequate hand hygiene was performed for 2 of 2 AVF’s (dialysis access) discontinued. (Patient #1, 6) Findings Include: 1. A policy titled, “Infection Control for Dialysis Facilities” (April 2023) indicated all teammates will perform hand hygiene prior to gloving and immediately after removal of gloves, after contamination with blood or other infectious material, after patient and dialysis system contact and before touching clean areas such as supplies. 2. During an observation on 06/16/2025 at 2:51 PM, PCT 3 discontinued Patient #6’s AVF treatment. PCT 3 failed to perform hand hygiene prior to gloving and immediately after removal of gloves throughout the observation and was observed retrieving clean supplies from stock with contaminated gloves on. 3. During an observation on 06/16/2025 at 3:25 PM, PCT 3 discontinued Patient #1’s AVF treatment. PCT failed to perform hand hygiene prior to gloving and immediately after removal of gloves throughout the observation. 4. During an interview on 06/18/2025 at 10:07 AM, PCT 3 indicated the expectation when removing and putting on new gloves is to complete hand hygiene. 5. During an interview on 06/20/2025 at 12:14 PM, PCT 2 indicated the expectation is to complete hand sanitation when removing and prior to putting on new gloves.”

    Rule V0113. Standard-level.

  • Ic - Items Taken To Station Disposed/Dedicated Or Disinfected

    The inspectors’ words, 235 words

    “IC-IF TO STATION=DISP/DEDICATE OR DISINFECT CFR(s): 494.30(a)(1)(i) Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient. -- Nondisposable items that cannot be cleaned and disinfected (e.g., adhesive tape, cloth covered blood pressure cuffs) should be dedicated for use only on a single patient. -- Unused medications (including multiple dose vials containing diluents) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients. This Standard is not met as evidenced by: 44230 Based on observation, record review, and interview, staff failed to ensure adequate disinfection of equipment for 1 of 1 RN assessments observed. (RN 1) Findings Include: A policy titled, “Infection Control for Dialysis Facilities” (April 2023) indicated stethoscopes are to be disinfected with an alcohol prep pad and/or 1:100 bleach solution if visibly contaminated. During an observation on 06/18/2025 at 10:37 AM, RN 1 was observed completing a patient assessment on Patient #3 using her stethoscope. RN 1 failed to disinfect her stethoscope after use. During an interview on 06/23/2025 at 9:50 AM, RN 1 indicated the expectation is to disinfect the stethoscope using bleach and/or an alcohol pad after use with each patient.”

    Rule V0116. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 270 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 44230 Based on observation, record review, and interview, the facility failed to ensure adequate disinfection of dialysis station for 2 of 2 dialysis station disinfections observed. (Station #7 and #11) Findings Include: 1. A policy titled, “Infection Control for Dialysis Stations” (April 2023) indicated at the end of each treatment, the dialysis station will be cleaned and disinfected. The dialysis station must be completely vacated by the previous patient before teammates can begin disinfection of the station. 2. During an observation of a station disinfection on 06/16/2025 at 3:01 PM, PCT 3 disinfected the dialysis machine using a bleach solution while Patient #6 was sitting in the dialysis chair holding his/her dialysis access sites after needle removal. 3. During an observation of a station disinfection on 06/16/2025 at 3:53 PM, PCT 3 disinfected the dialysis machine and patient television, using a bleach solution, while Patient #1 was sitting in the dialysis chair holding his/her dialysis access sites after needle removal. 4. During an interview on 06/18/2025 at 10:07 AM, PCT 3 indicated dialysis stations should be vacated by the previous patient prior to disinfection for the next patient. 5. During an interview on 06/23/2025 at 12:14 PM, PCT 2 indicated that patients must vacate the dialysis station prior to disinfecting for the next patient.”

    Rule V0122. Standard-level.

  • Ic - Catheters; General

    The inspectors’ words, 499 words

    “IC-CATHETERS:GENERAL CFR(s): 494.30(c)(2) (2) The “Guidelines for the Prevention of Intravascular Catheter-Related Infections” entitled “Recommendations for Placement of Intravascular Catheters in Adults and Children” parts I - IV; and “Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients,” Morbidity and Mortality Weekly Report, volume 51 number RR-10, pages 16 through 18, August 9, 2002. The Director of the Federal Register approves this incorporation by reference in accordance with 5 U.S.C. 552(a) and 1 CFR Part 51. This publication is available for inspection as the CMS Information Resource Center, 7500 Security Boulevard, Central Building, Baltimore, MD or at the National Archives and Records Administration (NARA). Copies may be obtained at the CMS Information Resource Center. For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_regulations/ibr_locations.html This Standard is not met as evidenced by: 44230 Based on observation, record review, and interview, staff failed to ensure adequate CVC disinfection measures were taken to prevent infection for 2 of 2 CVC exit site dressing changes (PCT 2, RN 1), and 1 of 2 CVC treatments discontinued, (PCT 3) Findings Include: 1. A policy titled, “Central Venous Catheter (CVC) with Clearguard HD Antimicrobial End Caps Procedure” indicates a 30 second disinfection time using 2% Chlorhexidine Gluconate (Chloraprep-skin disinfectant) when completing CVC exit site disinfection. For discontinuation of CVC treatment, discard used barrier and place a new clean, moisture proof barrier under the catheter to prevent contamination. Do not allow the CVC hub to touch non-sterile surfaces. 2. During an observation on 06/18/2025 at 10:10 AM, PCT 2 disinfected the CVC exit site for Patient #7 using Chloraprep (skin disinfectant) for 12 seconds. During an interview on 06/18/2025 at 10:22 AM, PCT 2 indicated the expectation for disinfecting a CVC exit site using Chlorprep was 30 seconds. 3. During an observation on 06/18/2025 at 10:37 AM, RN 1 disinfected the CVC exit site for Patient #7 using Chloraprep for 13 seconds. During an interview on 06/18/2025 at 10:51 AM, RN 1 indicated the expectation for disinfecting a CVC exit site using Chloraprep is 30 seconds. RN 1 indicated she felt like it was disinfected Patient #7’s CVC exit site for 30 seconds but should have timed it. 4. During an observation on 06/23/2025 at 10:05 AM, PCT 3 discontinued the CVC treatment for Patient #8. PCT 3 failed to replace the CVC barrier at the end of treatment and failed to secure the open ends of the CVC, leaving them open and lying of the dirty barrier, failing to secure the lines in her hands. During an interview on 06/23/2025 at 12:22 PM, PCT 3 indicated the CVC barrier would only be discarded and a new barrier replaced if it appears visibly soiled. The CVC limbs are considered sterile and should be always secured. During an interview on 06/23/2025 at 12:14 PM, PCT 2 indicated the CVC limbs should be secure in hands at all times when connecting/disconnecting with clean barrier used.”

    Rule V0146. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 520 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 44230 Based on observation, record review, and interview, the medical director failed to ensure policy and procedure were followed regarding securement of medications and water log documentation for 1 of 1 facility observed. Findings Include: Medications unsecured A policy titled, “Medication Policy” (October 2023) indicated all refrigerated medications are to be locked at the close of each business day or if not under supervision by the licensed teammate. During an observation on 06/16/2025 at 12:05 PM, the medication refrigerator housing Mircera (medication used to treat anemia) and vaccinations were found unlocked/unsecured. A second medication refrigerator housing Intradialytic Parenteral Nutrition (nutrient support therapy administered intravenously) was also found to be unlocked/unsecured. RN 1 was in the isolation room tending to a patient’s treatment. During an interview on 06/16/2025 at 12:17 PM, RN 1 indicated that all medications should be locked/secured when not in use. Documentation of Waterlogs A policy titled, “Medical Record Corrections” (October 2023) indicated that paper medical record entry is to be erased to include use of correction fluid, obliterated, altered or destroyed. Erroneous or unclear entries in a paper medical record are to be corrected or clarified by drawing a single line through the erroneous entry, write the word erroneous entry or error entry beside the crossed-out item with the date and teammate signature and credentials. Enter corrected data/information adjacent to the erroneous entry or on the next available line as an addendum. A document titled, “CWP Daily Water Log” dated 04/21/2025 evidenced lines 30, 31, 32, 34 and 35 had been altered using correction tape with data entered over the correction tape. During an interview on 06/18/2025 at 2:10 PM, the Biomed Manager indicated correction tape should never be used to correct paper charting. The incorrect information should have a line through it. During an interview on 06/18/2025 at 2:15 PM, the FA indicated that correction tape should not be used to make corrections to the waterlogs. She is unaware of who used the correction tape and indicated her initials are on the document, but she did not alter this record. During an interview on 06/20/2025 at 8:05 AM, PCT 1 indicated that PCT 3 was responsible for using the correction tape to alter the data on 04/21/2025. She further indicated PCT 3 was new and did not know she was not allowed to do this explaining to her that no records could be altered in that manner. PCT 1 caught this mistake and found other entries that were also altered with correction tape and had PCT 3 redo the entire page, but she missed this one. During an interview on 06/23/2025 at 12:22 PM, RN 1 indicated that correction tape should not be used to alter records. Staff should be putting a line through the erroneous data and initial it.”

    Rule V0715. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jun 23, 2025Standard inspection5 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Apr 4, 2017.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis and peritoneal dialysis.
  • Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
  • 12 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 2 dialysis facilities CMS lists in Wayne County, 2 have a star rating from CMS: 1 rated 3 of 5, 1 rated 2 of 5.
  • CMS rates this one 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

1 compared
PlaceStar rating
Fmc - Richmond3

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.