Davita Irish at Home
A dialysis facility in South Bend, Indiana 46614
4350 South Ironwood Dr, South Bend, Indiana 46614. (574) 299-4529.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.
- 2of 5 CMS’s star rating
- Not rated patient survey rating
- 7 deficiencies cited in the last three years
- 20 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Apr 10, 2025: a standard inspection.
7 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
7 deficiencies in 1 month of the last 36. Last cited Apr 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Apr 10, 2025: standard inspection7 deficiencies
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 221 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 51751 Based on observation, record review, and interview, the facility failed to follow adequate hand hygiene and glove changes to prevent the spread of communicable diseases during 2 of 2 PCT observations. (PCT 2, 5) Findings include: 1. According to the “Infection Control for Dialysis Facilities” policy (04/2023), all teammates, Physicians and Non-Physician will perform hand hygiene prior to gloving and immediately after removal of gloves. 2. During an observation on 04/07/2025 at 12:46 PM, PCT 2 disconnected the bloodlines from Patient #14 but failed to sanitize her hands after removing the contaminated gloves and putting on new gloves. 3. During an observation on 04/08/2025 at 10:08 AM, PCT 5 initiated Patient #15’s dialysis treatment, removed gloves, and began charting on the computer without performing hand hygiene. 4. During an interview on 04/09/2025 at 12:51 PM, RN 3 indicated that anytime gloves are removed staff should perform hand hygiene. 5. During an interview on 04/09/2025 at 1:14 PM, PCT 2 indicated that the computer area is considered a clean area and hand hygiene should be performed prior to using.”
-
Ic - Wear Gowns, Shields/Masks; Staff Not Eat/Drink In Tx Area
The inspectors’ words, 411 words
“IC-GOWNS, SHIELDS/MASKS-NO STAFF EAT/DRINK CFR(s): 494.30(a)(1)(i) Staff members should wear gowns, face shields, eye wear, or masks to protect themselves and prevent soiling of clothing when performing procedures during which spurting or spattering of blood might occur (e.g., during initiation and termination of dialysis, cleaning of dialyzers, and centrifugation of blood). Staff members should not eat, drink, or smoke in the dialysis treatment area or in the laboratory. This Standard is not met as evidenced by: 51751 Based on observation, record review, and interview, the facility failed to ensure staff and visitors wore appropriate personal protective equipment (PPE) while in the treatment area during 1 of 2 observation days. (04/07/2025) Findings include: 1. According to the “Infection Control for Dialysis Facilities” policy (04/2023), appropriate fluid resistant/fluid impervious gowns will be worn by all teammates, Physicians and Non-Physicians, and visitors when in the treatment area. 2. During an observation on 04/07/2025 at 12:30 PM, Patient #3 was receiving his/her dialysis treatment. Patient #3’s spouse was sitting next to him and failed to wear a protective gown on the treatment floor. 3. During an observation on 04/07/2025 at 12:47 PM, PCT 2 was observed on the treatment floor assisting with patients’ dialysis treatments. Her PPE, gown, was cut at the bottom, shortening the length. 4. During an interview on 04/07/2025 at 12:30 PM, Patient #3’s spouse indicated that he/she sits with Patient #3 during each treatment and PPE has not offered or provided for use when on the treatment floor. 5. During an interview on 04/07/2025 at 1:14 PM, PCT 2 indicated she had altered her PPE, gown, by cutting the bottom. Tape became adhered to her gown, so the PPE was cut. She indicated that PPE should not be altered in any way and does not normally alter it. 6. During an interview on 04/07/2025 at 4:34 PM, the Administrator indicated that all visitors should wear PPE on the treatment floor per facility policy. She has been educating the staff regarding this requirement but acknowledged that some staff have been advised while others have not. The Administrator indicated that staff should not be altering PPE in any way. 7. During an interview on 04/09/2025 at 12:51 PM, RN 3 indicated that visitors are expected to wear PPE when on the treatment floor and staff should not be altering PPE. 8. During an interview on 04/09/2025 at 1:14 PM, PCT 2 indicated visitors are required to wear PPE while on the treatment floor.”
-
Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols
The inspectors’ words, 277 words
“IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 51751 Based on observation, record review, and interview, the facility failed to maintain procedures in cleaning and disinfection of contaminated surfaces, medical devices, and equipment during 2 of 2 observations of dialysis station disinfections. (Station #3, #7) Findings include: 1. According to the “Infection Control for Dialysis Facilities” policy (04/2023), at the end of each treatment, the dialysis station will be cleaned and disinfected. Surfaces to disinfect include all surfaces in contact with the patient or their belongings and frequently contacted by healthcare personnel. 2. During an observation on 04/07/2025 at 12:30 PM, PCT 6 disinfected Station #3, but failed to disinfect the TV and the inside of the prime container on the dialysis machine after the previous patient vacated the station. 3. During an observation on 04/07/2025 at 1:05 PM, PCT 3 failed to disinfect the inside of the prime container, and the counter located behind the dialysis chair at Station #7. 4. During an interview on 04/08/2025 at 9:27 AM, PCT 6 indicated she forgot to disinfect the TV after the previous patient vacated Station #3 and further indicated the TV should be included when disinfecting a dialysis station, she just forgot to disinfect it. 5. During an interview on 04/09/2025 at 1:14 PM, PCT 2 indicated that station disinfection included the inside of the prime container and TV.”
-
Ic - Staff Education Re Catheters/Catheter Care
The inspectors’ words, 340 words
“IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 51751 Based on observation, record review, and interview, the facility failed to ensure adequate infection control procedures were performed to prevent CVC infections on 2 of the 2 CVCs observed. (Patient #16, 17) Findings include: 1. According to the “Central Venous Catheter (CVC) with ClearGuard HD Antimicrobial End Caps” policy (10/2024), staff should perform a 15 second disinfect of the CVC during the process of connecting or disconnecting for the blood lines using an alcohol pad. 2. During an observation of a CVC initiation on 04/08/2025 at 9:56 AM, PCT 6 accessed Patient #17’s CVC and failed to disinfect the venous hub using an alcohol pad for 15 seconds. 3. During an observation on 04/08/2025 at 10:07 AM, PCT 5 accessed Patient #16’s CVC but failed to disinfect the hubs of the CVC lines using an alcohol pad for 15 seconds. 4. During an interview on 04/08/2025 at 10:17 AM, PCT 7 indicated that CVC hubs are to be disinfected using an alcohol pad for 15 seconds. 5. During an interview on 04/09/2025 at 12:51 PM, RN 3 indicated that CVC hubs should be disinfected with an alcohol pad for 5-10 seconds each line.”
-
Pe - Equipment Maintenance - Manufacturer’S Dfu
The inspectors’ words, 207 words
“PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 51751 Based on observation, record review, and interview, the facility failed to follow the preventative maintenance schedules for 1 of 1 facility observed. Findings include: 1. According to the “Preventative Maintenance Schedules for Equipment” policy (10/2023), all miscellaneous equipment will receive preventative maintenance performed by trained Biomed teammate or outside vendors per manufacturer’s recommendations. 2. During an observation on 04/07/2025, 2 intravenous (IV) pumps located in the medication area were found to not have inspection dates. 3. During an interview on 04/09/2025 at 11:11 AM, the Biomed indicated that sometimes the bleach used to disinfect takes the service stickers off the equipment, he is reviewing the service logs to determine if the pumps were serviced. 4. During an interview on 04/10/2025 at 9:46 AM, the Biomed indicated that the pumps were not serviced and have been removed from the treatment floor. The Biomed further indicated that the IV pumps were to be maintained annually by an outside vendor.”
-
Va Monitor To Prevent Failure/Stenosis
The inspectors’ words, 244 words
“POC-VA MONITOR/PREVENT FAILURE/STENOSIS CFR(s): 494.90(a)(5) The patient’s vascular access must be monitored to prevent access failure, including monitoring of arteriovenous grafts and fistulae for symptoms of stenosis. This Standard is not met as evidenced by: 51751 Based on observation, record review, and interview, the facility failed to assess the Arterial Venous Fistula (AVF) prior to cannulation (inserting the dialysis needles) on 2 of 2 patients observed. (Patient # 11, 12) Findings include: 1. According to the “AV Fistula or Graft Cannulation with JMS Sysloc Mini Safety Fistula Needles and Administration of Heparin Loading Dose” policy (04/2025), staff are to perform inspection, auscultation with a stethoscope, and palpation on the entire length of access to determine presence of bruit and thrill. 2. During an observation on 04/08/2025 at 10:25 AM, PCT 6 initiated Patient #11’s dialysis treatment and failed to listen to the AVF prior to cannulation. 3. During an observation on 04/08/2025 at 10:15 AM, PCT 8 initiated Patient #12’s dialysis treatment and failed to assess the AVF access site prior to cannulation. 4. During an interview on 04/09/2025 at 12:51 PM, RN 3 indicated that staff are expected to assess the AVF access site before cannulation, including listening to the site with a stethoscope. 5. During an interview on 04/09/2025 at 1:14 PM, PCT 2 indicated that AVF access sites are to be checked prior to cannulation by looking at the site, feeling the site and listening to the site with a stethoscope.”
-
Md Resp - Ensure All Adhere To P&P
The inspectors’ words, 1,132 words
“MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 51751 Based on record review and interview, the medical director failed to ensure staff followed policies and procedures regarding initial nursing assessments to be completed prior to start of treatment for 2 of 2 new patients reviewed. (Patients #2, 3), appropriate labeling and storage of medications, storage of supplies, and monitoring supplies for expiration and appropriately discarding for 1 of 1 facility observed. Findings include: Initial Assessment Prior to 1st Treatment 1. According to the “Initial Patient Nursing Assessment for New Patients” policy (04/2024), a registered nurse (RN) as required by federal regulations will perform an initial pretreatment evaluation of all patients prior to the initiation of their first treatment at the facility. 2. During a record review of Patient # 2 on 04/08/2025, the initial RN assessment was documented on 01/27/2025 at 7:17 AM. The patient’s treatment was initiated at 6:29 AM. The facility failed to document an initial nursing assessment prior to the start of the initial treatment. 3. During a record review of Patient #3 on 04/08/2025, the initial RN assessment was documented on 03/18/2025 at 6:09 AM. The patient’s treatment was initiated at 6:06 AM. The facility failed to document an initial nursing assessment prior to the start of the initial treatment. 4. During an interview on 04/09/2025 at 11:03 AM, the Administrator indicated that she did not know if the initial assessment had to be documented prior to start of first treatment. 5. During an interview on 04/09/2025 at 12:51 PM, RN 3 indicated that the RN must complete the initial assessment prior to the start of a new patient’s initial treatment. Meds drawn up with no time/initials & unsecured 1. According to the “Medication Policy” policy (10/2023), if the medication is not immediately administered or is to be administered by another teammate, the medication must be labeled with the patient’s name, name of medication, date, time prepared, dose, and initials of teammate preparing the medication. All medications are to be locked if not under the supervision by a licensed teammate. 2. During an observation of the Home Department on 04/07/2025 at 2:00 PM, the medication drawers located outside of the nurse’s station were found unlocked with the key resting inside the lock of one of the drawers. 3. During an observation on 04/08/2025 at 9:47 AM, PCT 6 was observed drawing up three syringes of Heparin (medication used to prevent blood from clotting) for Patient #13. PCT 6 failed to label the medication with a prepared time and her initials. The Heparin syringes were then placed on a counter located in center of the treatment floor unsecured, covered with a blue clean pad. 4. During an observation of 04/09/2025 at 10:20 AM, seven pre-made packets used for incoming patients included pre-drawn Heparin laying on the counter in the middle of the treatment floor, unsecured. Authorized staff failed to ensure the medications were secure while initiating or terminating patient treatments. 5. During an interview on 04/08/2025 at 12:50, RN 2 indicated that the medication drawers are typically open in the morning and locked prior to leaving for the day. The key was left in the drawer on 04/07/2025 during the surveyor flash tour because she had accessed the medications approximately one hour prior. RN 2 indicated she typically keeps the keys on her. 6. During an interview on 04/09/2025 at 10:23 AM, RN 5 indicated that medications should be secured and/or monitored when not in use. 7. During an interview on 04/09/2025 at 1:14 PM, PCT 2 indicated that medications, including heparin, should be monitored or secured if not being administered immediately. Storage of Supplies 1. According to the “Physical Environment” policy (04/2018), supplies will not be stored directly on the floor but stored on shelves or pallets. 2. During an observation of the water room on 04/07/2025 at 1:25 PM, 1 case of bleach was found sitting on the floor in the water room. 3. During an observation of the stockroom on 04/07/2025 at 1:32 PM, 2 cases of laboratory shipping supplies were found sitting on the floor. 4. During an observation of the Home Department on 04/07/2025 at 1:34 PM, 3 cases of Baxter 1.5% solution (peritoneal dialysis solution) were found sitting on the stockroom floor. 5. During an interview on 04/09/2025 at 12:51 PM, RN 3 indicated that supplies are to be kept off the floor and stored on pallets. 6. During an interview on 04/09/2025 at 1:14 PM, PCT 2 indicated that all supplies are to be kept off the floor and rotated with the older supplies near the front. Expired Supplies 1. According to the “Infection Control for Dialysis Facilities” policy (04/2023), staff will check expiration dates and package integrity prior to use. 2. According to the “Residual Bleach Testing Using RPC E-Z Chek Residual Chlorine (Bleach) Test Strips” policy (09/2013), staff should verify that strips are in date. 3. During an observation of the water room on 04/07/2025 at 1:25 PM, 2 bottles of residual chlorine test strips were found to be expired on 02/19/2025 and 03/20/2025. 4. During an observation of the Home Department on 04/07/2025 at 1:35 PM, Training Room #4 had expired hand soap at the clean sink, expired 01/2025, sixteen BD Vacutainers (used to collect blood) with an expiration date of 12/31/2024, four sterile surgical gloves, expired on 03/23/2025, and one 60 milliliter syringe with an expiration date of 03/01/2025. 5. During an observation of the Home Department on 04/07/2025 at 1:50 PM, Exam Room 1 had a Baxter 12-inch extension set (adaptor used to connect the peritoneal dialysis catheter to Baxter supplies) that had expired on 04/05/2024 and hand soap located at the clean sink had expired on 06/2023. 6. During an observation of the Home Department on 04/07/2025 at 2:00 PM, an antimicrobial end cap (used to cap off a peritoneal dialysis catheter) located in the laboratory area had expired on 02/23/2025. 7. During an observation of the Isolation Room on 04/08/2025 at 9:27 AM, 5 mint top blood collection tubes expired on 09/30/2024, 5 yellow top blood collection tubes expired on 10/31/2024, and 5 lavender top blood collection tubes expired on 02/28/2025. 8. During an interview on 04/07/2025 at 1:29 PM, the Biomed indicated that the staff that do the chlorine checks are responsible for checking expiration date on test strips. 9. During an interview on 04/08/2025 at 9:51 AM, RN 3 indicated that all supplies should be discarded and is monitored by all staff prior to using.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Apr 10, 2025 | Standard inspection | 7 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jul 14, 2015.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
- Doesn’t offer a shift starting at 5 p.m. or later.
- 20 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 2 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 6 dialysis facilities CMS lists in St Joseph County, 6 have a star rating from CMS: 4 rated 4 of 5, 2 rated 2 of 5.
- CMS rates this one 2 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.