Usrc Lafayette Dialysis

A dialysis facility in Lafayette, Indiana 47905

915 B Mezzanine Drive, Lafayette, Indiana 47905. (765) 448-4851.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.

The last 24 months 7 deficiencies in 1 month of the last 36. Last cited Oct 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Oct 18, 2024: a standard inspection.

7 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

7 deficiencies in 1 month of the last 36. Last cited Oct 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

7 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Oct 18, 2024: standard inspection7 deficiencies
  • Ic - Hbv - Vaccinate Patients & Staff

    The inspectors’ words, 841 words

    “IC-HBV-VACCINATE PTS/STAFF CFR(s): 494.30(a)(1)(i) Hepatitis B Vaccination Vaccinate all susceptible patients and staff members against hepatitis B. This Standard is not met as evidenced by: 47022 Based on record review and interview the clinic failed to evidence they vaccinated their patients, identified to be susceptible to Hepatitis B (liver infection), for Hepatitis B in 16 of 28 Patients identified with a Hepatitis B surface antibody of less than 10 (susceptible to Hepatitis B) and who were not vaccinated, nor declined the vaccine nor were nonconverters (after 2 series of Hepatitis B vaccines antibodies remain less than 10) Patients (Patients # 5, 8, 16, 19, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, and 36). Findings include: 1. A revised policy dated 11/2022, titled, “Patient Hepatitis B/Testing/Vaccination/Seroconversion,” indicated all Patients would be tested to ensure Patients are managed based on test results for anti-hbs (develops in a person successfully vaccinated against Hepatitis B) and would be completed annually. The policy indicated a physician order would be obtained and offered a vaccine to all susceptible patients within 3 days of the lab results. The policy indicated that if the anti-HBs declined to less than 10 after annual results a booster would be administered. 2. A Hepatitis Clinic Management form with Administrator documentation, received on 10/17/2024, indicated the following: A. Patient #5 had a Hepatitis B vaccine series in 2023, had a HBSQ (surface antibody) of <4 on 02/13/2024 and indicated a 2nd series would be offered. B. Patient #8 had a Hepatitis B vaccine series in 2017, 1 dose in 2020, had a HBSQ of <4 on 02/07/2024 and indicated a Hepatitis B vaccine would be offered. C. Patient #16 had a previous 1st Hepatitis B series vaccine, had a HBSQ <4 on 02/08/2024 and 07/25/2024, and indicated a 2nd series would be offered. D. Patient #19 had a Hepatitis B series, had a HBSQ <4 on 01/27/2024. and a series would be offered. E. Patient #25 had a previous 1st Hepatitis B series in 08/2022, had a HBSQ <4 on 02/07/2024, and a series would be offered. F. Patient #26 had HBSQ <4 on 06/26/2024, and a series would be offered. G. Patient #27 had a 1st Hepatitis B series in 2022, had a HBSQ <4 on 02/07/2024, and a series would be offered. H. Patient #28 had a HBSQ <4 on 02/07/2024, and a Hepatitis B series vaccine would be offered. I. Patient #29 had a HBSQ <4 on 02/08/2024, and a Hepatitis B series vaccine was ordered for November 2024. J. Patient #30 had a HBSQ <4 on 02/07/2024, and a Hepatitis B series vaccine would be offered. K. Patient #31 had a previous 1st Hepatitis B series, had a HBSQ <4 on 02/07/2024 and a Hepatitis B vaccine was ordered for November 2024. L. Patient #32 had a previous 1st Hepatitis B series, had a HBSQ <4 on 02/08/2024, and a 2nd Hepatitis B series vaccine would be offered. M. Patient #33 had a HBSQ <4 on 03/21/2024, and a Hepatitis B series vaccine was ordered for November 2024. N. Patient #34 had a HBSQ of 6 on 01/03/2024, and a Hepatitis B series vaccine would be offered. O. Patient #35 had a HBSQ <4 on 02/09/2024, and a Hepatitis B series vaccine would be offered. P. Patient #36 had a HBSQ <4 on 02/08/2024, and a Hepatitis B series vaccine would be offered. 3. During an interview on 10/16/2024 beginning at 7:30 PM, Registered Nurse (RN) 2 indicated the nurses look at Patients’ labs and determine if a Hepatitis B vaccine was needed. RN2 indicated Hepatitis B antibodies (protection from Hepatitis B if >10) were checked every month and Hepatitis B antigen (test for liver infection) were completed 2 times per year. 4. During an interview on 10/17/2024, beginning at 10:20 AM, RN 1 indicated he/she did not address the Hepatitis B labs. 5. During an interview on 10/16/2024, beginning at 7:45 PM, the Administrator indicated she began reviewing the Hepatitis B labs in July 2024, after becoming the Interim Administrator. The Administrator indicated the facility does not give Hepatitis B boosters, they do give Hepatitis B vaccine series; she relayed antibodies were checked every year and if the antibodies are <10 should be addressed; she relayed antigens were drawn monthly. She relayed for a Patient who received 2 series of Hepatitis B vaccine and their antibodies were not >10 after the 2 vaccine series, were considered nonresponsive. 6. During an interview on 10/18/2024, beginning at 8:40 AM, the Administrator indicated the HBSQ value on the lab results was the antibody test; if the antibodies were <10 the Patient was considered susceptible to Hepatitis B and should be offered a Hepatitis B vaccine. The Administrator indicated he/she had documented the Hepatitis B plan for each Patient on the Hepatitis B Clinic Management form, received on 10/17/2024. 7. During an interview on 10/17/2024, beginning at 12:00 PM, the Medical Director indicated the Facility’s Administrator should monitor the Hepatitis B labs and follow the Hepatitis B protocol.”

    Rule V0126. Standard-level.

  • Receive Information In An Understandable Way

    The inspectors’ words, 999 words

    “PR-RECEIVE UNDERSTANDABLE INFORMATION CFR(s): 494.70(a)(2) The patient has the right to- (2) Receive all information in a way that he or she can understand; This Standard is not met as evidenced by: 47022 Based on observation, record review, and interview the dialysis facility failed to ensure that a Spanish speaking patient received all information in a way that he or she could understand in 1 of 1 Spanish speaking patients observed (Patient #24). Findings include: 1. A policy, revised date 01/2020, titled, “Limited English Proficiency,” indicated limited English proficiency was defined as a person who could not speak, read write or understand the English language at a level that permitted them to interact effectively with health care providers. The policy indicated the dialysis facility would assess individual language needs upon initial contact, would utilize local interpreter resources/organizations and should contact the appropriate interpreter in the event that an interpreter was needed, outside of emergency situations, family members would not be used as interpreters unless specifically requested by the individual, children and other patients would not be used to interpret in order to ensure confidentiality of information and accurate communication, and the dialysis facility would reevaluate changes in the types of services or needs on an ongoing basis including mechanism for securing interpreter services and feedback from patients. 2. A revised policy dated 07/2024, titled, “Intradialytic Monitoring of Patient,” indicated patient teaching would include the Patient would recognize and report early signs or symptoms of complications. 3. A Plan of Care dated 03/14/2024 indicated Patient #24 was Spanish speaking and may not fully comprehend what he/she would read, Patient does not speak English, the family members interpret for Patient, and it was difficult to evaluate Patient’s understanding of medications related to the language barrier. A. A Psychosocial Progress note dated 08/22/2024 indicated the Social Worker [SW] spoke to Patient #24, Patient was wincing, the SW asked Patient if he/she was ok and Patient shook his/her head yes. The documentation indicated the SW asked Patient if he/she had any area of concern, and Patient shook his/her head no. The visit note failed to evidence a translation line was utilized or family members were contacted to translate and / or verify Patient understood the SW’s questions. B. An Adverse Occurrence Note dated 06/15/2024, indicated Patient #24 complained of headache, after Tylenol (pain reliever) was given the pain continued to escalate. The Note indicated Patient was not able communicate with staff or via interpreter and moaned and cried. C. A Patient Education Acknowledgement Form dated 09/11/2024, indicated Registered Nurse (RN) 2 instructed Patient #24 on flu and covid, resources for Patient and Patient Experience Survey via verbal instruction and handouts and Patient signed, acknowledging the education was received and was given an opportunity to ask questions. The documentation failed to indicate if a family member nor use of an interpreter. D. A request for Patient #24’s Emergency Training documentation was made on 10/18/2024 at 8:45 AM; the clinic failed to evidenced Patient received emergency training. E. During an observation on 10/17/2024, beginning at 10:50 AM, Patient #24 was observed at Station #3 receiving dialysis, no family member /interpreter was present, nor was there a staff member available that spoke Patient #24’s native language. During an interview on 10/17/2024, beginning at 10:50 AM, Patient Care Technician (PCT) 5, assigned to Patient #24, indicated Patient #24 was Spanish speaking only and the staff did not have a way to communicate with Patient. PCT 5 indicated Patient did get headaches, would make a face if he/she was having problems; PCT 5 indicated the staff would call Patient’s family member if unable to understand Patient. PCT 5 indicated Patient could not read Spanish to utilize Google Translate Application. When asked, PCT 5 indicated they were unaware of a translation line available to facilitate communication with Patient. F. During an interview on 10/17/2024, beginning at 10:50 AM, RN 1 indicated Patient #24 was Spanish speaking only and would utilize one PCT that could translate for Patient if the PCT was working. G. During an interview on 10/18/2024, beginning at 10:30 AM, RN 2 indicated he/she communicated the best they could with Patient #24, indicated they know if Patient has a problem by the expression on their face. RN 2 indicated Patient had ongoing headaches during dialysis, and they call Patient’s family member to communicate, if needed. H. During an interview on 10/16/2024, beginning at 7:00 PM, PCT 2 indicated during care, he/she does not use a translator line for Patient #24, would use the Google Translate Application, or would utilize the one PCT that could translate if available. PCT 2 indicated they would call the family member to communicate with Patient, if needed. PCT 2 indicated in the event emergency procedures were implemented, staff would need to disconnect Patient due to Patient would not understand the emergency disconnect procedures. I. During an interview on 10/17/2024, beginning at 1:55 PM, the SW indicated no discussion had yet occurred with Patient #24 regarding transplant. The SW indicated there were 4 Spanish speaking Patients in their dialysis clinic and the staff were to utilize a translation line for interpreting. J. During an interview on 10/16/2024, beginning at 6:25 PM, RN 2 indicated he/she would call a family member to translate for Patient #24 and did not use a translation line. K. During an interview on 10/17/2024, beginning at 12:00 PM, the Medical Director indicated the dialysis facility staff should utilize a translator line for communication with a Patient with a language barrier and should not utilize the Google Translate Application. The Medical Director indicated that the nephrology physician’s office connected to the dialysis facility had a translation device available however, the dialysis facility did not utilize the device. The Medical Director indicated concerns related to translation for Patients had been discussed with the governing body. L. During an interview on 10/18/2024, beginning at 8:40 AM, the Administrator indicated that the dialysis facility would begin staff in-service training for translation services available.”

    Rule V0453. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 573 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 47022 Based on record review and interview, the dialysis clinic failed to evidenced blood pressures, outside of standing orders or reportable parameters,were reported to the registered nurse [RN] per policy, in 2 of 3 Patients clinical records reviewed with an admission date after 04/08/2024 (Patient #2 and 6). Findings include: 1. A revised policy dated 07/2024, titled, “Intradialytic Monitoring of Patient,” indicated the charge nurse would be notified of vital signs outside of standing orders and/or reportable parameters. The policy indicated direct care staff would monitor the Patient’s volume status indicated by changes in blood pressure parameters. 2. A form dated 01/2020, titled, “Reportable Parameters to CN [clinical nurse],” indicated the Patient Care Technician (PCT) should report to charge nurse post dialysis systolic blood pressure >180 or diastolic blood pressure >100. 3. The clinical record for Patient #2, included a review of the most recent 10 Treatment Flow Sheets: A. The flow sheet dated 10/01/2024, indicated Patient’s blood pressure, post treatment, was 195/85. B. The flow sheet dated 10/05/2024, indicated Patients post treatment blood pressure was 178/111 and 189/87. C. The flow sheet dated 10/10/2024, indicated Patients post treatment blood pressure was 182/96. The record failed to evidence documentation the PCT notified the RN of the post treatment blood pressures outside of the reportable parameters on October 01, 05, and 10, 2024. 4. The clinical record for Patient #6, included a review the dialysis treatment flow sheets dated 9/21/24 to 10/15/24. The flow sheet, dated 9/21/24, included a post treatment orthostatic blood pressure (blood pressure change with change of position) of 172/72 sitting and 131/71 standing. The flow sheet dated 9/28/24 noted the post treatment orthostatic blood pressure of 188/83 sitting and 144/67 standing. The flow sheet dated 10/03/24 noted the post treatment orthostatic blood pressure was 184/62 sitting and 135/66 standing. The flow sheet dated 10/05/2024, noted the post treatment blood pressure was 146/124. The flowsheet dated 10/08/2024, the post treatment orthostatic blood pressure was 133/56 sitting and 99/66 standing. The flowsheet dated 10/10/2024, the post treatment orthostatic blood pressure was 165/98 sitting and 133/69 standing. The flowsheet dated 10/15/2024, the post treatment orthostatic blood pressure was 159/83 sitting and 139/77 standing. The Treatment Flow Sheets failed to evidence documentation the nurse was notified of the orthostatic blood pressure changes or the blood pressures outside of the reportable parameters. 5. During an interview on 10/16/2024, beginning at 7:00 PM, PCT 2 indicated vitals signs outside of the parameters should be reported to the nurse and documentation of the notification should be completed. 6. During an interview on 10/17/2024, beginning at 12:00 PM, the Medical Director indicated a systolic blood pressure greater than 180 may require an as needed blood pressure medication (clonidine) if the Patient had an order. If the Patient did not have an order for an as needed blood pressure medication, a systolic blood pressure greater than 180 would require notifying the physician. 7. During an interview on 10/18/2024, beginning at 10:00 AM, the Administrator indicated the PCT should notify the nurse and document a Patient’s blood pressure post dialysis treatment outside of reportable parameters and orthostatic blood pressure changes greater than 20 points.”

    Rule V0543. Standard-level.

  • Vascular Access - Monitor/Referrals

    The inspectors’ words, 430 words

    “POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 47022 Based on observation, record review, and interview, the clinic failed to ensure their staff cleansed the arteriovenous fistula (AVF) (entry into the blood vessel for hemodialysis [process to clean the blood of a patient whose kidneys do not work properly]) prior to cannulation (needle insertion) in 3 of 3 AVF cannulations observed (Patient Care Technicians 1, 2, and 3). Findings include: 1. A revised policy dated 10/2023, titled, “Assessment and Cannulation for AV Fistula/Graft and Patient Self Cannulation,” indicated the access preparation for an AVF would include to disinfect each access site separately with alcohol prep pad and repeat access preparation if cannulation area had been touched/contaminated. 2. During an observation on 10/16/2024 at station #4 beginning at 11:30 AM, Patient Care Technician (PCT) 2 cleaned Patient #13’s right AVF site with alcohol prep pads, then palpated the site again and cannulated using the 1st line without disinfecting the access prior to cannulation. Then PCT 2 palpated the AVF and cannulated the 2nd line. 3. During an observation on 10/17/2024, beginning at 9:35 AM, PCT 1 cleaned Patient #19’s left upper arm AVF site with alcohol prep pads, then palpated the site and cannulated the 1st line without disinfecting the access. PCT 2 then palpated the AVF and cannulated the 2nd line. PCT 1 failed to disinfect the area after the site was palpated and prior to cannulation. 4. During an observation on 10/17/2024, beginning at 9:40 AM, PCT 3 cleaned Patient #20’s left arm AVF site with alcohol prep pads at station #10, palpated the site and cannulated using the 1st line, and PCT 3 palpated the AVF and cannulated the 2nd line. PCT 3 failed to disinfect the area after the site was palpated and prior to cannulation. 5. During an interview on 10/16/2024, beginning at 7:00 PM, PCT 2 indicated an AVF site should not be palpated after being disinfected and if the site was to be re-palpated, disinfection with an alcohol pad was to be completed. 6. During an interview on 10/17/2024, beginning at 11:00 AM, PCT 3 indicated he/she tried not to palpate an AVF site after disinfecting and before cannulation; she indicated the AVF site should not be palpated after disinfection.”

    Rule V0550. Standard-level.

  • Va Monitor To Prevent Failure/Stenosis

    The inspectors’ words, 282 words

    “POC-VA MONITOR/PREVENT FAILURE/STENOSIS CFR(s): 494.90(a)(5) The patient’s vascular access must be monitored to prevent access failure, including monitoring of arteriovenous grafts and fistulae for symptoms of stenosis. This Standard is not met as evidenced by: 47022 Based on observation, record review, and interview, the dialysis facility failed to ensure the arteriovenous fistula (AVF) (entry into a blood vessel to receive hemodialysis [process to clean the blood of a patient whose kidneys do not work properly]) was auscultated (listening usually with a stethoscope) for a bruit (swishing sound caused by blood flow through an artery) in 2 of 3 AVF cannulations observed (PCT 1 and 3). Findings include: 1. A revised policy dated 10/2023, titled, “Assessment and Cannulation for AV Fistula/Graft and Patient Self Cannulation,” indicated an AVF access assessment would include palpating access for thrill (vibration felt by touch) and using a stethoscope to listen for a bruit. 2. During an observation on 10/17/2024, beginning at 9:30 AM, Patient Care Technician (PCT) 1 palpated Patient #19’s left upper arm AVF and cannulated (accessed with needle) the AVF without auscultating for a bruit, prior to cannulating the AVF. 3. During an observation on 10/17/2024, beginning at 9:40 AM, PCT 3 palpated Patient #20’s left AVF and cannulated the AVF, without auscultating for a bruit, prior to cannulating the AVF. 4. During an interview on 10/17/2024, beginning at 11:00 AM, PCT 3 indicated he/she does not auscultate the AVF for a bruit unless there are concerns with the thrill assessment. 5. During an interview on 10/17/2024, beginning at 5:00 PM, the Administrator indicated an AVF should be auscultated for a bruit prior to cannulation and each station had a dedicated stethoscope available for use.”

    Rule V0551. Standard-level.

  • Qapi Indicator - Infection Control - Trend/Plan/Act

    The inspectors’ words, 340 words

    “QAPI-INDICATOR-INF CONT-TREND/PLAN/ACT CFR(s): 494.110(a)(2)(ix) The program must include, but not be limited to, the following: (ix) Infection control; with respect to this component the facility must- (A) Analyze and document the incidence of infection to identify trends and establish baseline information on infection incidence; (B) Develop recommendations and action plans to minimize infection transmission, promote immunization; and (C) Take actions to reduce future incidents. This Standard is not met as evidenced by: 47022 Based on record review and interview, the clinic failed to evidence their quality assessment and performance improvement (QAPI) program in place included actions plans developed to promote Hepatitis B (liver infection) immunizations for hepatitis B susceptible patients for 1 of 1 clinic. Findings include: A Facility Quality Management meeting for the month of August 2024 indicated 57% of Patients had Hepatitis B antibodies <10 (susceptible to Hepatitis B). The Plan of Action for August 2024 indicated tracking tools were not utilized or not kept up to date, indicated low immunization rates were related to issues such as patient education, and labs which were not drawn, per policy. During an interview on 10/16/2024, beginning at 7:45 PM, the Administrator indicated he/she started tracking the Hepatitis B labs in July 2024, after becoming the Interim Administrator. During an interview on 10/17/2024, beginning at 10:20 AM, Registered Nurse (RN) 1 indicated he/she did not address the Hepatitis B labs. During an interview on 10/16/2024 beginning at 7:30 PM, RN 2 indicated the nurses look at Patients’ labs and determine if a Hepatitis B vaccine was needed. She indicated the Hepatitis B antibodies (protection from Hepatitis B if >10) were checked every month, the Hepatitis B antigen (test for liver infection) were completed 2 times per year. During an interview on 10/17/2024, beginning at 12:00 PM, the Medical Director indicated Facility’s Administrator should monitor the Hepatitis B labs and follow the Hepatitis B protocol. The Medical Director indicated infection issues were discussed during Quality Assessment and Performance Improvement meetings and if problems were noted audits and interventions were to be implemented.”

    Rule V0637. Standard-level.

  • Continuously Monitor/Take Action/Track/Sustain Improve

    The inspectors’ words, 225 words

    “QAPI-MONITOR/ACT/TRACK/SUSTAIN IMPROVE CFR(s): 494.110(b) The dialysis facility must continuously monitor its performance, take actions that result in performance improvements, and track performance to ensure that improvements are sustained over time. This Standard is not met as evidenced by: 47022 Based on record review and interview, the facility failed to ensure a quality assessment and performance improvement (QAPI) program was in place that systematically monitored the hepatitis B [liver infection] immunization status of all patients, with performance improvements activities and tracking in place to ensure improvements were sustained in 1 of 1 dialysis clinic. Findings include: A Quality Management Meeting note dated June 2024 indicated 61% of Patients had a Hepatitis B antibody <10 (susceptible to Hepatitis B), in July 2024 61% of Patients had a Hepatitis B antibody <10, and in August 2024 57% of Patients had a Hepatitis B antibody <10. During an interview on 10/16/2024, beginning at 7:45 PM, the Administrator indicated he/she started tracking the Hepatitis B labs in July 2024, after becoming the Interim Administrator. During an interview on 10/17/2024, beginning at 12:00 PM, the Medical Director indicated Facility’s Administrator should monitor the Hepatitis B labs and follow the Hepatitis B protocol. The Medical Director indicated infection issues were discussed during Quality Assessment and Performance Improvement meetings and if problems were noted audits and interventions were to be implemented. See V0126.”

    Rule V0638. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Oct 18, 2024Standard inspection7 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Oct 6, 2008.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: US Renal Care, Inc.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 12 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 1 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the US Renal Care, Inc. chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, better than expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 3 of 5 in CMS’s survey of in-center hemodialysis patients (55 interviews, Oct 18, 2024 to Jul 11, 2025): 56% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 53 of 5

How does it compare nearby?

  • Of the 3 dialysis facilities CMS lists in Tippecanoe County, 3 have a star rating from CMS: 2 rated 2 of 5, 1 rated 1 of 5.
  • CMS rates this one 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.