Hearth Record

Fmc - Corydon

A dialysis facility in Corydon, Indiana 47112

1141 Hospital Drive N.W., Ste B-1, Corydon, Indiana 47112. (812) 738-6200.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.

The last 24 months 8 deficiencies in 1 month of the last 36. Last cited Jun 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jun 3, 2024: a standard inspection.

8 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

8 deficiencies in 1 month of the last 36. Last cited Jun 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

8 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jun 3, 2024: standard inspection8 deficiencies
  • Ic - Sanitary Environment

    The inspectors’ words, 211 words

    “IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 38262 Based on observation, record review, and interview, the facility failed to follow facility policy regarding labeling bleach solution containers for 1 of 1 observation of a 1:10 bleach solution bottle. Findings include: A policy titled “Cleaning and Disinfecting the Dialysis Station” was provided by the Facility Administrator (FA) on 05/31/2024. The policy indicated that the 1:10 (add 1 part bleach to 10 parts of water) bleach solution will be stored in a labeled bottle. During an observation on 05/31/2024 at 8:10 AM, Patient Care Technician (PCT) 4 sprayed a clear solution from a bottle to clean up blood on the floor at station 3. At that time, PCT 4 stated that it was a 1:10 bleach solution. She was unsure why the bottle had no label indicating it was a 1:10 bleach solution. During an interview on 05/31/2024 at 9:10 AM, the Clinical Manager (CM) was unsure why the spray bottle was not labeled 1:10 bleach solution. She stated that the staff knew what was in the bottle.”

    Rule V0111. Standard-level.

  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 398 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 38262 Based on observation, record review, and interview, the facility staff failed to ensure patients removed gloves and performed hand hygiene after applying pressure to the atrioventricular (AV) access site for 1 of 2 AV discontinuation observations (Patient #10) and failed to ensure clean items (medical tape) were stored in a designated clean area for 1 of 4 facility observation days. (Treatment floor) Findings include: 1. A policy titled “Access Assessment and Cannulation” was provided by the Facility Administrator (FA) on 05/31/2024. The policy indicated that a multi-use tape roll must be prepared in a clean area. The tape can be torn into strips, tabbed at one end, and stacked on top of one another. The policy indicated the last strip serves as a barrier and should not be placed on the patient. When ready to cannulate (insert tube into vein), the stacked torn tape should be retrieved from the clean area. The policy indicated that once gloves are removed, hand hygiene should be performed. 2. During the flash tour on 05/28/2024 at 9:00 AM, staff had applied stacked pre-torn paper tape to the front of the dialysis machine at station 9. The staff failed to retrieve the pre-torn tape from a clean area and place the tape on the chair side table. During an interview on 05/31/2024 at 12:00 PM, the Director of Nursing stated staff were not to stick the pre-torn paper tape to the front of the dialysis machine. 3. During an observation on 05/30/2024 at 9:45 AM, Patient #10 removed their glove but did not perform hand hygiene after applying pressure to their AV access site during discontinuation. Patient Care Technician (PCT) 1 failed to ensure Patient #10 performed hand hygiene and failed to offer hand sanitizer after glove removal and before leaving the station. During an interview on 05/30/2024 at 3:00 PM, the Director of Operations and the Clinical Manager stated Patient #10 should perform hand hygiene after holding pressure to their access site. During an interview on 06/03/2024 at 12:20 PM, the Medical Director stated that the expectation was for staff to follow the facility policy regarding infection control procedures.”

    Rule V0113. Standard-level.

  • Ic - Items Taken To Station Disposed/Dedicated Or Disinfected

    The inspectors’ words, 329 words

    “IC-IF TO STATION=DISP/DEDICATE OR DISINFECT CFR(s): 494.30(a)(1)(i) Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient. -- Nondisposable items that cannot be cleaned and disinfected (e.g., adhesive tape, cloth covered blood pressure cuffs) should be dedicated for use only on a single patient. -- Unused medications (including multiple dose vials containing diluents) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients. This Standard is not met as evidenced by: 49228 Based on observation, record review, and interview, the facility failed to ensure cleaning and disinfecting of stethoscopes between patient uses for 3 of 3 observations. Findings include: 1. A policy titled “Cleaning and Disinfecting the Dialysis Station” indicated that reusable equipment, such as a stethoscope, should be cleaned and disinfected between patient use. 2. During an observation on 05/29/2024 at 11:57 AM, Registered Nurse (RN) 1 failed to clean and disinfect the stethoscope used between patients at station #11 and station #1. 3. During an observation on 05/30/2024 at 7:07 AM, RN 1 failed to clean and disinfect the stethoscope after completing a nursing assessment on patient #7. 4. During an observation on 05/31/2024 at 7:53 AM, RN 1 failed to clean and disinfect the stethoscope used between patients at station #6 and station #9. 5. During an interview on 05/31/2024 at 10:58 AM, RN 1 indicated placing a glove over the stethoscope as a barrier when assessing patients and cleaning the stethoscope with alcohol after. 6. During an interview on 05/31/2024 at 12:00 PM, the Director of Operations (DOO) stated that staff should not use a glove over the end of a stethoscope as a barrier. She noted that the stethoscope should be disinfected between patient use.”

    Rule V0116. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 284 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 38262 Based on observation, record review, and interview, the facility failed to follow applicable infection control procedures when cleaning and disinfecting contaminated surfaces and equipment for 2 of 2 staff observations of treatment stations being cleaned and disinfected. (RN 1, RN 2) Findings include: 1. A policy titled “Cleaning and Disinfecting the Dialysis Station” was provided by the Facility Administrator (FA) on 05/31/2024. The policy indicated that after a patient leaves the station, staff should disinfect the TV, counter, and oxygen concentrator with a bleach solution consisting of 1:100 (1 parts bleach to 100 parts water). 2. During an observation on 05/30/2024 at 8:12 AM, Registered Nurse (RN) 2 failed to disinfect station #6’s TV screen and countertop behind the dialysis machine. 3. During an observation on 05/31/2024 at 10:47 AM, RN 1 failed to disinfect station #8’s TV screen, the countertop behind the dialysis machine, and the oxygen concentrator. RN 1 stated she had finished cleaning the station despite the three areas not being disinfected. 4. During an interview on 05/31/2024 at 12:00 PM, the Clinical Manager (CM) and Director of Operations (DOO) stated the TV, countertops, and oxygen concentrator should be disinfected after the patient leaves the station. 5. During an interview on 06/03/2024 at 12:20 PM, the Medical Director stated that the expectation was for staff to follow the facility policy regarding infection control procedures.”

    Rule V0122. Standard-level.

  • Pe - Building - Constructed/Maintained To Ensure Safety

    The inspectors’ words, 251 words

    “PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 49228 Based on observation, record review, and interview, the facility failed to maintain a secure building to ensure staff and patient safety for 1 of 4 facility observation days. Findings include: 1. A policy titled “Physical Security and Facility Access” indicated, but was not limited to, all external employee entrance doors to remain closed and locked. 2. During an observation on 06/03/2024 at 8:25 AM, the external employee entrance door was propped open. 3. During an observation on 06/03/2024 at 8:43 AM, Registered Nurse (RN) 2 and Patient Care Technician (PCT) 5 discussed the external door being propped open. PCT 5 indicated that the external staff door had been propped open by PCT 5 on break but was no longer propped open when PCT 5 went to re-enter the building. 4. During an interview on 06/03/2024 at 8:44 AM, PCT 5 indicated not knowing the code to get in the building and had propped the door open. 5. During an interview on 06/03/2024 at 8:55 AM, the Director of Operations indicated the external doors to facility to remain closed and locked at all times. 6. During an interview on 06/03/2024 at 12:20 PM, the Medical Director indicated the external doors should not be propped open, as these doors should remain closed and locked.”

    Rule V0402. Standard-level.

  • Vascular Access - Monitor/Referrals

    The inspectors’ words, 269 words

    “POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 38262 Based on observation, record review, and interview, the facility staff failed to ensure cannulation sites were not touched again after skin antisepsis for 2 of 2 staff observations of an arteriovenous (AV) fistula initiation. (RN 2, PCT 4) Findings include: 1. A policy titled “Access Assessment and Cannulation” was provided by the Facility Administrator (FA) on 05/31/2024. The policy indicated the correct practice was to avoid touching the cannulation (insert the tube into a vein) site after disinfection. 2. During an observation on 05/30/2024 at 7:15 AM, Registered Nurse (RN) 2 failed to avoid touching Patient #7’s AV cannulation site after she cleaned with alcohol and before inserting a needle. 3. During an observation on 05/31/2024 at 6:20 AM, Patient Care Technician (PCT) 4 failed to avoid touching Patient #11’s AV cannulation site after she cleaned with alcohol and before inserting the needle. 4. During an interview on 05/31/2024 at 12:00 PM, the Clinical Manager (CM) and Director of Operations stated staff are not to touch the AV access site after cleaning and before accessing with a needle. 5. During an interview on 06/03/2024 at 12:20 PM, the Medical Director stated that the expectation was for staff to follow the facility policy regarding infection control procedures.”

    Rule V0550. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 240 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 49228 Based on observation, record review, and interview, the Medical Director failed to ensure the facility followed their own policies and procedures regarding medication administration for 3 of 3 patient medication administration observations. (Patient #6, Patient #8, & Patient #15) Findings include: 1. A policy titled “Medication Preparation and Administration” indicated, but was not limited to, “Follow the principles below for medication preparation and administration. Right Drug. Right Dose. Right Route. Right Time. Right Patient. Right Documentation ...The person who prepares the medication must be the person who will administer the medication.” 2. During an observation on 05/30/2024 at 10:07 AM, RN 1 failed to observe patient #8 taking the medication provided. 3. During an observation on 05/31/2024 at 10:04 AM, RN 1 failed to observe patient #15 taking the medication provided. 4. During an observation on 05/31/2024 at 10:13 AM, RN 1 failed to observe patient #6 taking the medication provided. 5. During an interview on 05/31/2024 at 12:00 PM, the Director of Operations (DOO) and the Clinical Manager (CM) stated that they expected the nurse to observe the patient taking their medication.”

    Rule V0715. Standard-level.

  • Mr - Protect Patient Records From Loss/Keep Confidential

    The inspectors’ words, 436 words

    “MR-PROTECT PT RECORDS FM LOSS/CONFIDENTIAL CFR(s): 494.170(a) The dialysis facility must- (1)Safeguard patient records against loss, destruction, or unauthorized use; and (2) Keep confidential all information contained in the patient’s record, except when release is authorized pursuant to one of the following: (i) The transfer of the patient to another facility. (ii) Certain exceptions provided for in the law. (iii) Provisions allowed under third party payment contracts. (iv) Approval by the patient. (v) Inspection by authorized agents of the Secretary, as required for the administration of the dialysis program. This Standard is not met as evidenced by: 49228 Based on observation, record review, and interview, the facility failed to ensure patients’ medical records were secured for 3 of 4 facility observation days. Findings include: 1. A policy titled “Storing, Filing, Thinning, and Retrieving of Medical Records” indicated, but was not limited to, “Hard charts must be placed in chart racks or carts or medical record rooms that are locked during nonwork hours ...Responsibility: Authorized employees who oversee and maintain facility medical records.” 2. During an observation on 05/29/2024 at 8:25 AM, the door to patient medical records was propped open without personnel present. 3. During an observation on 05/30/2024 at 6:40 AM, the door to patient medical records was propped open without personnel present. 4. During an observation on 05/31/2024 at 4:44 AM, the door to patient medical records was propped open without personnel present. 5. During an observation on 05/31/2024 at 6:15 AM, Patient #6 left the restroom located next to where patient records are kept, the door to patient medical records was propped open, and there were no employees present monitoring the door or patient records. 6. During an interview on 05/31/2024 at 6:58 AM, Patient Care Technician (PCT) 3 indicated the door to patient medical records does not have to be shut, but is locked when facility is closed. 7. During an observation on 05/31/2024 at 7:00 AM, the Facility Administrator (FA) closed the door to the patient’s medical records. 8. During an interview on 05/31/2024 at 7:00 AM, the FA indicated the door to patient medical records does not have to be closed and is usually open and has a receptionist in that area. The FA believed patients would not enter the opened medical record room if personnel were not around. The FA stated that the door was left open the previous night before leaving the facility, but it was closed when the last employee left. The FA stated she called PCT 1 who confirmed that the door to the patient medical records was open when they arrived to open the facility.”

    Rule V0727. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jun 3, 2024Standard inspection8 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on May 8, 2008.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 12 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 4 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 54 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 2 dialysis facilities CMS lists in Harrison County, 2 have a star rating from CMS: 1 rated 5 of 5, 1 rated 4 of 5.
  • CMS rates this one 4 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

1 compared
PlaceStar rating
Davita Corydon Dialysis Center5

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.