Dialysis Care Center - Hazel Crest
A dialysis facility in Hazel Crest, Illinois 60429
18325 Pulaski Road Unit A-B, Hazel Crest, Illinois 60429. (708) 824-7900.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 1of 5 CMS’s star rating
- Not rated patient survey rating
- 6 deficiencies cited in the last three years
- 12 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Sep 19, 2024: a standard inspection.
6 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
6 deficiencies in 1 month of the last 36. Last cited Sep 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Sep 19, 2024: standard inspection6 deficiencies
-
Ic - Sanitary Environment
The inspectors’ words, 336 words
“IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 34411 Based on document review, observation, and interview, it was determined that the Facility failed to ensure that a sanitary environment was maintained, by not following protocol/policies related to pest control on the treatment floor. Findings include: 1. The Facility’s policy titled, “Bed Bug Management in the Dialysis Facility” was reviewed, and required, “...Procedure: Follow the steps in the table below to get rid of bed bugs if suspected or confirmed on a patient, bedding, or equipment...Notify the Charge Nurse, Clinical Manager, Vice President of Operations, Quality & Regulatory Department, the Attending Physician and Medical Director of a potential infestation. Contact Facility Maintenance who will then notify Housekeeping, Environmental Services or Pest Control if applicable...” 2. The Facility’s grievance log from 4/2024-8/2024, was reviewed. A grievance (dated 7/10/2024) included, “Subject of Complaint: Flies on unit more than 1 time...” 3. The Facility’s Adverse Events from 4/2024-9/16/2024, were reviewed. An adverse event related to Pt #1 (dated 9/14/2024), indicated that a bed bug was collected (on 9/14/2024). Pt #1’s clinical record was reviewed and lacked any documentation (MD notification, Clinical manager notification, Pest control notification) regarding the suspected bed bug sighting. 5. The Facility’s QAPI meeting minutes from 7/2023-7/2024 were reviewed. The meeting minutes did not include any documentation of discussion of bugs (flies, gnats, or bedbugs). 6. On 9/16/2024 at 9:50 AM-11:50 AM, an observational tour of the dialysis treatment area was conducted. During the tour, flying bugs were noted and near patient dialysis stations. 7. On 9/18/2024 at 2:30 PM, an interview was conducted with the Clinical Manager (E #1). E #1 acknowledged that the Quality meeting minutes did not include any documentation regarding pest control. E #1 stated that the staff should follow the protocol if there are suspected bed bug sightings.”
-
Ic - Aseptic Techniques For Iv Meds
The inspectors’ words, 242 words
“IC-ASEPTIC TECHNIQUES FOR IV MEDS CFR(s): 494.30(b)(2) [The facility must-] (2) Ensure that clinical staff demonstrate compliance with current aseptic techniques when dispensing and administering intravenous medications from vials and ampules; and This Standard is not met as evidenced by: 34411 Based on document review, observation, and interview, it was determined that 1 of 1 medication refrigerator, the Facility failed to ensure that expired medications were discarded and not available for patient use. Findings include: 1. The Facility’s policy titled, “Medication Preparation and Administration” (dated 11/20/2021), was reviewed, and required, “...If multi-dose vial been opened or accessed, the vial should be dated and initiated upon opening and discarded within 28 days...Tubersol [TB] will be discarded on 30 days as stated per manufacturer directions. The beyond-use date should never exceed the manufacturer’s expiration date...” 2. On 9/16/2024 at 9:50 AM, an observational tour of the dialysis treatment area was conducted. During the tour, the medication refrigerator was observed for medication expiration dates. The medication refrigerator contained 1 opened tubersol (TB) vial dated 7/8/2024 (greater than 28 days); 1 box of Daptomycin (antibiotic) with an expiration date of 8/2024; and 5 pneumococcal syringes with an expiration date of 8/2024. 3. On 9/16/2024 at 9:55 AM, an interview was conducted with the Registered Nurse (E #2). E #2 stated that once the TB vial is opened, it is good for 28 days. E #2 stated that expired meds should be discarded once they have expired.”
-
Ic - Staff Education Re Catheters/Catheter Care
The inspectors’ words, 325 words
“IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 34411 Based on document review, observation, and interview, it was determined that for 1of 2 (E #3) staff observed performing CVC (Central Venous Catheter) disinfection, the Facility failed to ensure that the appropriate infections control measures were adhered, in order to prevent catheter-related infections. Findings include: 1. The Facility’s procedure titled, “Changing an External Catheter Dressing” (dated 7/5/2023), was reviewed and required, “Catheter dressings will be changed in accordance with [Facility] policy and procedures...” 2. On 9/16/2024 between 9:50 AM and 11:50 AM, an observational tour of the dialysis treatment area was conducted. During the tour, the following was observed: - At approximately 10:45AM, at Station #12, the PCT (E #3/Patient Care Technician), removed Pt #8’s old catheter exit site dressing, prior to initiating treatment. Pt #8’s treatment was initiated. However, Pt #8’s exit site was not cleaned and covered with a new dressing until after the treatment was initiated. 3. On 9/16/2024 at 11:00 AM, an interview was conducted with E #3. E #3 stated that the patient’s catheter dressings should be done prior to starting the treatment.”
-
Pe - Comfortable Temperature
The inspectors’ words, 289 words
“PE-COMFORTABLE TEMPERATURE CFR(s): 494.60(c)(2) The dialysis facility must: (i) Maintain a comfortable temperature within the facility; and (ii) Make reasonable accommodations for the patients who are not comfortable at this temperature. This Standard is not met as evidenced by: 34411 Based on document review, observation, and interview, it was determined that for 1 of 1 treatment floor, the Facility failed to ensure that the environmental temperature was maintained at a comfortable temperature for the patients. Findings include: 1. The Facility’s “Patient Grievance Log”, from 4/2024-8/2024, was reviewed. The log’s grievance (dated 6/2/2024), included, Subject of Complaint: Temp of treatment floor...Date of Resolution: 6/3 emailed maintenance...” 2. On 9/19/2024, maintenance logs were requested. The Facility was unable to provide. 3. On 9/18/2024 at 1:45 PM, a tour of the Facility was conducted. The Facility’s temperature was not at a comfortable temperature. During the tour, patients were interviewed regarding the Facility’s temperature. Pt #9 stated that the Facility’s temperature has been cold for years. Pt #9 stated that the temperature fluctuates and that it is hard for them to regulate the thermostat. Pt #9 stated that the staff are aware that a lot of the patients complain about the temperature. 4. On 9/16/2024 at approximately 9:15 AM, an interview was conducted with the Administrative Assistant (E #4). E #4 stated that the Facility is cold all the time and that it is hard to control the temperature. E #4 stated that patients do complain about the treatment area being cold. 5. On 9/19/2024 at 9:45 AM, an interview was conducted with the Clinical Manager (E #1). E #1 acknowledged that the Facility’s temperature was under 70 degrees Fahrenheit. E #1 stated that the temperature should be set at 73 degrees Fahrenheit.”
-
Appropriateness Of Dialysis Rx
The inspectors’ words, 648 words
“PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 34411 A. Based on document review, observation, and interview, it was determined that for 1of 3 patients (Pt #7) observed for order verification, the Facility failed to ensure that the correct dialyzer was on the hemodialysis machine and the heparin was administred, as ordered. Findings include: 1. The Facility’s policy titled, “Management of Hemodialysis Adequacy In-Center Hemodialysis (ICHD), dated 8/5/2021, was reviewed, and required, “...Factors Effecting Adequacy: Dialyzer: Interventions: Evaluate for appropriate dialyzer size based on TW [target weight] with the physician. Is patient dialyzing on the correct dialyzer type and size based on prescription?” 2. The clinical record of Pt #7 was reviewed on 9/16/2024. Pt #7’s hemodialysis orders included an order (dated 8/10/2024) for a dialyzer F160. 3. On 9/16/2024 at 9:50 AM, an observational tour of the dilaysis treatment area was conducted. Duirng the tour, the preseciptions of 3 patients whose treatments were initiated, were verified by matching the order with the machine. At Station #8, Pt #7’s machine contained a F180 dialyzer. However, Pt #7’s prescription required a F160. 4. On 9/16/2024 at 10:20 AM, an interview was conducted with the Registered Nurse (E #2). E #2 stated that prescriptions should be followed as ordered. B. Based on document review and interview it was determined that in 3 of 6 (Pts. #1, 2 and 4) records reviewed for dialysis prescription, the facility failed to ensure the blood flow rates were administered as ordered. Findings include: 1. The Facilitiy’s policy titled “Monitoring During Dialysis Treatment” (dated 5/11/2020) was reviewed on 9/19/2024, and required “...Check and record the following machine parameters and any problems...Blood Flow Rate...” 2. On 9/18/2024, the clinical record of Pt #1 was reviewed. Pt #1 was admitted on 6/18/2024, with a diagnosis of ESRD (end stage renal disease). Pt #1’s clinical record included an order (dated 9/17/2024) for Pt #1 to be dialyzed with a blood flow rate (BFR) of 400 for 3 hours. However, the following were noted on the dialysis treatment sheets: - On 8/27/2024, Pt #1 was dialyzed with a BFR of 300 from 10:36 AM until 1:32 PM (2 hours and 56 minutes) - On 9/3/2024, Pt #1 was dialyzed with a BFR of 300 from 12:44 PM until 1:32 PM (48 minutes) 3. On 9/18/2024, the clinical record of Pt #2 was reviewed. Pt #2 was admitted on 3/1/2024, with a diagnosis of ESRD. Pt #2’s clinical record included an order (dated 3/1/2024) for Pt #2 to be dialyzed with BFR of 400 for 2 hours and 45 minutes. However, the following were noted on the dialysis treatment sheets: - On 8/28/2024, Pt #2 was dialyzed with a BFR of 300 from 3:08 PM until 5:07 PM (1 hour and 59 minutes) - On 9/2/2024, Pt #2 was dialyzed with BFR of 300 from 3:08 PM until 4:388 PM (1 hour 30 minutes) 4. On 9/18/2024, the clinical record of Pt. #4 was reviewed. Pt. #4 was admitted on 3/2/2020, with a diagnosis of end stage renal disease (ESRD). Pt. #4’s clinical record contained a physician’s order dated 8/6/2024 that required Pt. #4 be dialyzed with a blood flow rate (BFR) of 450 for 3 hours and 30 minutes. However, the following were noted on the dialysis treatment sheets: - On 8/21/2024 Pt. #4 was dialyzed with a BFR of 300 from 4:33 PM until 6:43 PM (2 hours and 10 minutes). - On 8/27/2024 Pt. #4 was dialyzed with a BFR of 350 from 11:02 AM until 1:59 PM (2 hours and 57 minutes). 5. On 9/19/2024 at approximately 10:30 AM, findings were discussed with E #1 (Clinical Manager). E #1 stated that the physician order should have been followed.”
-
Measure, Analyze And Track Quality Indicators
The inspectors’ words, 257 words
“QAPI-MEASURE/ANALYZE/TRACK QUAL INDICATORS CFR(s): 494.110(a)(2) The dialysis facility must measure, analyze, and track quality indicators or other aspects of performance that the facility adopts or develops that reflect processes of care and facility operations. These performance components must influence or relate to the desired outcomes or be the outcomes themselves. This Standard is not met as evidenced by: 34411 Based on document review and interview, it was determined that for 10 of 10 patients reviewed for mortality, the Facility failed to ensure that a quality indicator was analyzed to identify the cause of patient deaths, as a part of the Quality Improvement Plan, in order to monitor and implement performance action plans. Findings include: 1. The Facility’s policy titled, “Quality Assessment and Performance Improvement” (dated 4/23/2021) was reviewed and required, “...The dialysis facility will measure, analyze, and track quality indicators or other aspects of performance that the facility adopts or develops that reflect processes of care and facility operations...” 2. On 9/19/2024 at 10:00 AM, the Facility’s QAPI activities and meeting minutes were reviewed with the Clinical Manager (E #1). Review of mortality data indicated that from 1/2024-7/2024, there were 10 patient deaths. The QAPI performance activities related to mortality, included the number of deaths. However, there was no data indicating the cause of death or any documentation that analyzed and tracked trends in patient deaths at the Facility. 3. On 9/19/2024 at 10:15 AM, an interview was conducted with the Clinical Manager (E #1). E #1 acknowledged that the QAPI meetings lacked analysis of patient deaths.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Sep 19, 2024 | Standard inspection | 6 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Nov 8, 2019.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 12 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- CMS lists it as independent, not owned or managed by a chain.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, worse than expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 1 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 150 dialysis facilities CMS lists in Cook County, 136 have a star rating from CMS: 10 rated 5 of 5, 28 rated 4 of 5, 41 rated 3 of 5, 37 rated 2 of 5, 20 rated 1 of 5.
- CMS rates this one 1 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.