Fmc - of Metropolis
A dialysis facility in Metropolis, Illinois 62960
20 Hospital Drive, Metropolis, Illinois 62960. (618) 524-3046.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 2of 5 CMS’s star rating
- Not rated patient survey rating
- 8 deficiencies cited in the last three years (needs attention)
- 10 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean4
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
- Condition-level deficiency
- For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.
What did inspectors find?
The last inspection on record was on May 29, 2025: a standard inspection.
8 deficiencies cited in the last three years, 1 of them at condition level, the most serious.
1 deficiency at condition level, the more serious of CMS’s two levels
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
8 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Condition-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
May 29, 2025: standard inspection8 deficiencies
-
Cfc - Infection Control
The inspectors’ words, 143 words
“CFC-INFECTION CONTROL CFR(s): 494.30 This Condition is not met as evidenced by: 49741 Based on document review, observation, and interview, it was determined that the Facility failed to comply with the Condition for Coverage 42 CFR 494.30, Infection Control. Findings include: 1. The facility failed to ensure hand hygiene was performed and personal protective equipment was donned as required. See V113. 2. The facility failed to provide a sanitary environment to minimize the transmission of infectious agents within and between patients. See V122. 3. The facility failed to ensure expired medications were not available for patient use. See V143. 4. The facility failed to ensure the water treatment room, Biotech work room, and storage room floors and counters were maintained in a sanitary environment. See V111. 5. The facility failed to ensure supplies were stored off the floor to prevent contamination. See V117”
-
Ic - Sanitary Environment
The inspectors’ words, 896 words
“IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 39025 A. Based on document review, observation, and interview, it was determined that the Facility failed to follow infection control precautions by not maintaining a clean, safe, and aesthetically pleasant environment for patient, as required. Findings Include: 1. On 05/27/25 at approximately 11:00 AM, an observational tour of the dialysis treatment room was conducted. The room was observed to be disheveled with too numerous to count trash items on the floor around each dialyzer machines and treatment chairs (1-10), on the stainless steel patient scale, and in the lab area on the treatment floor. The wood paneling on the wall of the treatment center, behind the dialysis chairs, was warped and splintered. Observed in part were plastic cap lids, zip ties, 2” x 2” gauze pads, packets of alcohol pads, and a used face mask. 2. On 5/28/25 the Facility’s policy titled, “Cleaning and Disinfecting the Dialysis Station” (Published 9/5/23), was reviewed and noted, “Procedure: ...6. Pick up all trash or visible medical debris from around the patient chair.” The Facility’s policy titled, “Policy: All areas must be kept clean and organized, including but not limited to treatment areas, water/supply rooms, offices and restrooms. Walkways must be kept clear of debris and free of clutter.” 3. On 5/27/25 at approximately 2:00 PM, an interview was conducted with the Clinic Manager (E#2). E #2 observed and verbally confirmed that the room should have been cleaned up before staff left the prior treatment day. B. Based on observation and staff interview, it was determined that for 10 out of 10 stations, the Facility failed to ensure the wall boxes/drains were clean and free of buildup. Findings include: 1. On 5/27/25 at approximately 12:20 PM, a tour of the dialysis treatment area was conducted. The Dialysis Wall Boxes/Drains behind dialysis chairs 1-8 housed rusted hose clamps and dark brown/rust-colored stains, as well as crystalized acid sediment on the hose connector sites. The connector boxes behind chairs 9 and 10 contained heavy crystalized acid sediment. 2. The Facility policy title “Cleaning and Disinfecting the Dialysis Station” (Published 9/5/23) was reviewed. It indicated “Cleaning of the Dialysis Wall Boxes: Dialysis wall boxes and the area/wall around the wall box must be routinely cleaned at the end of each treatment day or immediately if splattered with blood ... Work Surface Cleaning and Disinfection without Visible Blood using Bleach Solutions: All work surfaces shall be cleaned and disinfected with 1:100 bleach solution after completion of procedures. Make the surface glisteningly wet and let air dry ...” 3. On 5/27/25 at approximately 1:15 PM an interview was conducted with the Clinic Manager (E#2) and Biomedical Operations Manager (E#3) who both observed all wall units and verbally agreed they have not been cleaned on a regular basis. C. Based on observation, document review, and staff interview, it was determined the End Stage Renal Disease (ESRD) Facility failed to ensure the water treatment room, biotech work room, and storage room floors and counters were maintained in a sanitary environment to minimize the transmission of infectious agents. Findings include: 1. On 05/27/25 between 12:20 PM and 1:30 PM, a tour of the water treatment room, biotech work area, and storage room were conducted with Biomedical Operations Manager (E #3). The following was noted: a. Storage room - Floors were soiled and had debris on floor, dust, and white chemical residue dried on floor. b. Bio-Tech work area - An electronic machine board part, an empty bag, a red cap, and various other debris lay on the floor and under the shelving units. Dust and debris covered counter surfaces. 2. At the eye wash station a yellow repair work order paper had been wet, then dried stuck to the drain on the floor. a. The electrical wall outlet measuring approximately 3 ½ feet in length was completely covered in rust. b. Water Treatment Room - Floors were soiled, debris on floor and under storage rack, white chemical residue and a puddle of water on floor. 1. The acid loop bypass tank had dry acid crystallized covering the connectors on the tank. 2. The acid prep and storage area were soiled with sediment and debris on the floor. 3. The chlorine water testing cart had a heavily soiled chuck pad with spots of black debris where the testing strips were used. Behind the cart on the floor was an open bottle of chlorine test strips. 4. The hot water heater was rusted around the entire bottom surface of the tank. 5. Underneath the rinse ports station on the wall, a pool of water was observed on the floor. 3. The facility policy titled, “General Cleanliness and Infection Control Guidelines” (dated 05/05/25) was reviewed. The policy notes, “ ... All areas must be kept clean and organized, including but not limited to “ ... treatment areas, water/supply rooms, offices, and restrooms. Walkways must be kept clear of debris and free of clutter.” 4. On 05/27/25 at approximately 1:30 PM, an interview with the Biomedical Operations Manager (E #3) was conducted. (E#3) acknowledged and verbally agreed the observations above needed to be corrected and maintained in a sanitary manner.”
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 236 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 49741 Based on observation, interview, and document review, it was determined for 1 of 2 Patient Care Tech observations, the Facility failed to ensure hand hygiene was performed. Findings include: 1. On 5/28/23 at approximately 11:00 AM, an observational tour of the treatment floor was conducted. The Patient Care Tech (E#6) failed to use hand hygiene and change gloves after disposing items in the trash can, located centrally on the treatment floor, and then back to patient to drop pre-packaged items to patient in chair #4. 2. On 5/29/23 at approximately 11:00 AM, the policy titled, “Hand Hygiene” was reviewed. The policy stated, “Policy: ...Hands Will Be ... Decontaminated using alcohol-based hand rub or by washing hands with antimicrobial soap and water: ... After contact with inanimate objects near the patient ... After contact with other objects within the patient station or treatment space.” 3. An interview was conducted with the Clinic Manager, (E#2) on 5/28/25 at 1:00 PM. E#2 stated, “I will talk to (E#6) regarding this situation. She is a float, but should have been using hand hygiene and changing gloves after leaving the patient chair to dispose items into the trash.””
-
Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts
The inspectors’ words, 269 words
“IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 39025 Based on document review, observation, and interview, it was determined the End Stage Renal Dialysis center (ESRD) failed to ensure supplies were stored off the floor to prevent contamination. Findings Include: 1. On 05/27/25 at 12:20 PM, an observational tour was conducted of the water room with Bio-med Operations manager, employee (E#3). Observed sitting directly on the floor was one large box of acid loop tubing. 2. The facility policy titled, “Storage of Supplies” dated 04/05/21 was reviewed. It noted, “... supplies ... must be stored off the floor ... “ 3. On 05/25/25 at 12:25 PM, an interview was conducted with (E#3). (E#3) observed and verbally agreed the box of tubing should be stored off the floor and on a pallet or shelving.”
-
Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols
The inspectors’ words, 247 words
“IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 49741 Based on document review, observation, and interview, it was determined that for 1 of 2 technicians (E#5) observed cleaning and disinfecting dialysis stations, the Facility failed to follow infection control precautions by not cleaning/disinfecting equipment, as required. Findings Include: 1. On 5/28/25 at approximately 11:30 AM Patient Care Technician (E#5) was observed cleaning dialysis station 10. After cleaning all surfaces, E#5 did not allow the dialysis chair to fully air dry before returning to sitting position and closing the arms of the chair. 2. On 5/28/25 the Facility’s policy titled, “Cleaning and Disinfecting the Dialysis Station” (Published 9/5/23), was reviewed and noted, “Work Surface Cleaning and Disinfection without Visible Blood using Bleach Solutions: All work surfaces shall be cleaned and disinfected with 1:100 bleach solution after completion of procedures. Make the surface glisteningly wet and let air dry ...” 3. On 5/28/25 at approximately 2:30 PM, an interview was conducted with the Clinic Manager (E#2). E #2 observed and verbally confirmed that the dialysis chairs should be fully reclined with chair arms open to allow adequate time for surfaces to air dry in order to provide sufficient disinfectant contact time.”
-
Ic - Aseptic Techniques For Iv Meds
The inspectors’ words, 217 words
“IC-ASEPTIC TECHNIQUES FOR IV MEDS CFR(s): 494.30(b)(2) [The facility must-] (2) Ensure that clinical staff demonstrate compliance with current aseptic techniques when dispensing and administering intravenous medications from vials and ampules; and This Standard is not met as evidenced by: 39025 Based on observation, facility documentation, and staff interview it was determined the End Stage Renal Dialysis (ESRD) center failed to ensure outdated medications and biological’s were not available for patient use. Findings Include: 1. On 05/27/25 at approximately 11:00 AM an observational tour of the dialysis treatment room was conducted. The following was noted - a. 4 bottles of Germ Star instant hand sanitizer, 16 oz (ounce) with an expiration date of 03/25. b. A 1 ml (milliliter) vial Epoetin 20,000 U (units)/ml, vial found in refrigerator opened, expiration date 1/29/25. c. A 3 ml vial BD Vacutainer PST (plasma separating tube) Gel and Lithium Heparin 56 U, found on counter with puncture hole. 2. A facility policy titled, “Sequestering Medications” dated 09/26/18 was reviewed. It noted, “ ... Medications that are expired, defective, damaged, ... may pose a significant health threat and safety risk to paients and need to be sequestered.” 3. On 05/27/25 at approximately 1:00 PM, Clinic Manager (E#2) observed and acknowledged the expired items stating, “These expired items should have been discarded.””
-
Dialysis Access Type & Maintenance
The inspectors’ words, 210 words
“PA-DIALYSIS ACCESS TYPE & MAINTENANCE CFR(s): 494.80(a)(8) The patient’s comprehensive assessment must include, but is not limited to, the following: (8) Evaluation of dialysis access type and maintenance (for example, arteriovenous fistulas, arteriovenous grafts and peritoneal catheters). This Standard is not met as evidenced by: 49741 Based on observation, document review and interview, it was determined for 2 of 9 (Stations #1 and 6) patients, the Facility failed to ensure that vascular access was visible at all times. Findings include: 1. On 5/28/25 at approximately 11:30 AM, the following patients had their CVC access site covered: a. Patient in Station #1 had a blanket covering the patient’s CVC access site in the right upper chest. b. Patient in Station #6 had a blanket covering the patient’s CVC access site in the right upper chest. 2. The policy titled, “Patient Monitoring and Safety Checks During Hemodialysis Treatment” (published 9/5/2023) was reviewed on 5/29/2024 at approximately 10:00 AM. The policy indicated under “Safety Check-Access: ...Confirm each patient’s face and access are uncovered.” 3. On 5/28/25 at approximately 1:00 PM, an interview was conducted with the Clinic Manager (E#2). E #2 stated, “I will have an in-service regarding this and other issues. All patients must have their access sites visible at all times.””
-
Clia Labs/Meet Needs Of Patients
The inspectors’ words, 362 words
“LAB-CLIA LABS/MEET NEEDS OF PTS CFR(s): 494.130 The dialysis facility must provide or make available, laboratory services (other than tissue pathology and histocompatibility) to meet the needs of the ESRD patient. Any laboratory services, including tissue pathology and histocompatibility must be furnished by or obtained from, a facility that meets the requirements for laboratory services specified in part 493 of this chapter. This Standard is not met as evidenced by: 39025 Based on review of observation, laboratory contract documentation, and staff interview, it was determined the End Stage Renal Dialysis (ESRD) center failed to ensure biologicals had not exceeded the expiration date. Findings include: 1. On 05/27/25 at 11:00 AM, an observational tour of the patient treatment room was conducted with Clinic Manager (E#2). The following items were noted: a. In the mini refrigerator for lab specimens were two lavender top tubes of blood. One tube was labeled (Pt#6) DOB (date of birth): 08/20/48, dated 05/23/25; The second tube was labeled (Pt#2) DOB: 11/28/74, dated 05/23/25. b. On the counter beside the lab refrigerator were two yellow top serum separating tubes of blood. One tube was labeled (Pt#5) and the DOB and date were illegible; the second tube was labeled (Pt#7) DOB: 02/09/68, dated 05/26/25. 2. A facility contract titled, “... Laboratory Services Agreement”, was reviewed. It noted, “ ... 10. Each facility shall be responsible for all proper preparation and packaging of specimens for shipment to (name of lab) ... “ 3. On 05/27/25 at 1:00 PM, (E#2) observed and acknowledge the purple top tubes in the refrigorator and the yellow top tubes on the counter. (E#2) stated, “The purple tops are good for 2 days and the yellow tops are good for 7 days. I don’t know why there was not a pick-up on Friday, 05/23/25, so the purple tops are no longer good. The yellow tops are not good even with the date of 05/26/25, since they were left out on the counter.” When asked what the lab pick-up schedule was for this center, (E#2) stated, “We use Fedex and they pick-up on Monday, Wednesday, and Friday, but we can call and request a pick-up at any time.” .”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| May 29, 2025 | Standard inspection | 8 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jul 22, 2009.
- Run for profit.
- Cited at For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. in the last three years: it didn’t meet a whole condition of Medicare’s rules for dialysis facilities.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
- Doesn’t offer a shift starting at 5 p.m. or later.
- 10 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, worse than expected; hospital admissions, worse than expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 2 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- No other dialysis facility CMS lists is in Massac County.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.