Fmc - Piedmont Dialysis North
A dialysis facility in Marietta, Georgia 30064
1720 Powder Springs Rd, Marietta, Georgia 30064. (678) 402-6048.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 3 deficiencies cited in the last three years (needs attention)
- 17 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean4
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
- Condition-level deficiency
- For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.
What did inspectors find?
The last inspection on record was on Feb 5, 2025: a complaint inspection.
3 deficiencies cited in the last three years, 1 of them at condition level, the most serious.
1 deficiency at condition level, the more serious of CMS’s two levels
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
3 deficiencies in 2 months of the last 36. Last cited Feb 2025. Most serious: Condition-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Feb 5, 2025: complaint inspection2 deficiencies
-
Cfc - Governance
The inspectors’ words, 130 words
“CFC-GOVERNANCE CFR(s): 494.180 This Condition is not met as evidenced by: 03383 Based on facility record review and staff interviews, it was determined that the Governing Body failed to demonstrate responsibility and accountability for the operations of the facility. This deficient practice had the potential to negatively affect the health and safety of 39 patients who dialyzed at this facility. Findings include: Cross-Reference: V757 - Failure of the Governing Body to ensure that the facility had adequate number of qualified staff to meet the needs of all patients and provide safe patient care; and to be in compliance with the minimum State required staffing ratios of one licensed and qualified nurse for every 12 patients who were receiving dialysis care and one qualified patient care giver for every four patients.”
-
Staff # & Ratio Meet Patient Needs
The inspectors’ words, 1,230 words
“GOV-STAFF # & RATIO MEET PT NEEDS CFR(s): 494.180(b)(1) The governing body or designated person responsible must ensure that- (1) An adequate number of qualified personnel are present whenever patients are undergoing dialysis so that the patient/staff ratio is appropriate to the level of dialysis care given and meets the needs of patients; This Standard is not met as evidenced by: 03383 Based on staff interviews, a review of facility records, and a review of minimum state required staffing ratios, it was determined that the Governing Body failed to ensure the facility employed an adequate number of qualified staff to meet the needs of all patients as evidenced by a lack of at least one licensed and qualified nurse (who was not counted as a dialysis care giver in the staff-to-patient ratio of one dialysis care giver to four patients), who was readily available to provide nursing care, take charge and deal with unexpected complications of dialysis, for every 12 patients receiving dialysis care and that each care giver was not assigned more than four patients at any given time. This deficient practice had the potential to cause a delay in monitoring patients for issues such as fluid overload (an excessive amount of fluid in the body), changes in vital signs, or problems with the dialysis equipment. Additionally, insufficient staffing could mean slower responses to alarms, delayed adjustments, or missed complications including but not limited to: intradialytic hypotension (sudden drops in blood pressure which can occur when fluid is removed too rapidly), arrhythmias (irregular heartbeat), and other medical issues and emergencies related to hemodialysis. The facility census was 39. Findings include: During an interview on 2/5/25 at 9:05 a.m., Patient Care Technician (PCT) BB stated there were two shifts and some days, there were call outs in the morning and it was hard to find someone to cover that early in the morning. Stated they usually work with four staff on Monday, Wednesday, and Friday (MWF) and the charge nurse does not work the floor. During an interview on 2/5/25 at 9:13 a.m., Registered Nurse/Charge Nurse (RN/CN) AA stated the facility recently started dialysis treatments on Tuesday,Thursday, and Saturday (TTS). There were seven patients on first shift and two patients on second shift and was staffed with one RN and one PCT. The nurse was responsible for initiating and terminating dialysis treatment for patients with a central venous catheter (CVC - a thin, flexible tube inserted into a large vein near the heart to provide access for hemodialysis) and the PCT was responsible for patients with other types of access. RN/CN AA stated she did not have to complete some of the duties of a charge nurse on TTS and she and the PCT worked well together to get the work done. RN/CN AA stated this was the way TTS was scheduled, one nurse and one PCT. A review of treatment flowsheets and staff/patients assignment sheets dated 1/21/25 and 1/23/25 revealed the following: On Tuesday, 1/21/25 First Shift: A review of records showed there were seven patients on the first shift who dialyzed on 1/21/25. There was one Registered Nurse (RN DD) and one Patient Care Technician (PCT CC) who worked on 1/21/25. A review of staff/patients assignment sheet showed that PCT CC was assigned to three patients (P) in Pod B (P#2, P#4, and P#9). There was no patient care giver who was assigned to care for four patients in Pod A (P#3, P#6, P#7 and P#8). - There were five patients (P#3, P#4, P#7, P#8, and P#9) with a CVC access. RN DD was responsible for the initiation and termination of dialysis treatment, assessment and performing catheter care for P#3, P#4, P#7, P#8, and P#9 in addition to conducting all pre and post dialysis assessments, preparation and administration of all prescribed medications, addressing patient complaints, physician notification, dealing with unforeseen complications of dialysis/medical issues, and emergency situations that could arise during dialysis treatment for seven patients. - A review of treatment flowsheets dated 1/21/25 showed that PCT CC initiated and discontinued dialysis treatment for five patients (P#2, P#3, P#4, P#6, and P#9). PCT CC monitored P#2, P#3, P#4, P#6, P#7, and P#8. In addition, it was documented that PCT CC initiated, terminated, and/or completed assessments on the following patients with a CVC: assessed CVC and terminated dialysis treatment on P#3; terminated dialysis treatment on P#4; assessed and terminated dialysis treatment on P#7; and assessed and terminated dialysis treatment on P#9 via CVC. On Thursday, 1/23/25 First Shift: A review of records showed there were eight patients on the first shift who dialyzed on 1/23/25. There was one RN/Charge Nurse (RN AA) and one PCT (PCT CC) who worked on 1/23/25. A review of staff/patients assignment sheet showed PCT CC was assigned to patients in Pod B (P#1, P#2, P#4, and P#5). There was no patient care giver who was assigned to care for four patients in Pod A (P#3, P#6, P#7 and P#8) on 1/23/25. - There were five patients (P#3, P#4, P#5, P#7, and P#8) with a CVC access. RN AA was responsible for the initiation and termination of dialysis treatment, assessment and performing catheter care for P#3, P#4, P#5, P#7, and P#8 in addition to conducting all pre and post dialysis assessments, preparation and administration of all prescribed medications, and performing other routine nursing duties. Furthermore, RN AA was also responsible for dealing with unforeseen complications of dialysis/medical issues and emergency situations that could arise during dialysis treatment for eight patients. - PCT CC initiated and discontinued dialysis treatment for two patients (P#2, and P#6) and primarily monitored P#2 and P#6 during treatment. RN AA and PCT CC both monitored P#3 and P#8. It was also documented that PCT CC initiated and terminated dialysis treatment and assessed CVC on P#3; and terminated treatment on P#4 via CVC. During an interview on 2/5/25 at 11:00 a.m., the Facility Administrator stated that the nurse performed CVC assessments, initiation, and termination of treatment for patients with a CVC access. During an interview on 2/5/25 at 11:28 a.m., RN DD stated that she initiated and terminated dialysis treatment and performed dressing changes for patients with CVC on 1/21/25. RN DD could not explain why PCT CC documented performing those tasks. An interview was conducted with the Director of Operations (DO), Facility Administrator, and Senior Director of Regulatory Affairs (SDRA) on 2/5/25 at 11:45 a.m. related to staffing requirements. The SDRA had additional questions to clarify the deficient practice with staffing issues. A call was placed to Specialized Care Unit Program Manager. During a telephonic interview with the Program Manager, DO, Facility Administrator, and SDRA on 2/5/25 at 12:05 p.m., the Program Manager explained the minimum state required staffing ratios of one licensed and qualified nurse for every 12 patients receiving dialysis care AND (emphasis was made on the word “AND”) one dialysis care giver for each four patients. The Program Manager further explained that when a nurse is assigned to care for patients in a Pod, the nurse is designated as a patient care giver. There must be one nurse who is not counted as a dialysis care giver in the staff-to-patient ratio of one dialysis care giver to four patients, who is readily available to provide nursing care, take charge and deal with unexpected complications of dialysis, other medical issues and emergencies, for every 12 patients receiving dialysis care.”
Apr 5, 2024: standard inspection1 deficiency
-
Qapi Indicator - Infection Control - Trend/Plan/Act
The inspectors’ words, 290 words
“QAPI-INDICATOR-INF CONT-TREND/PLAN/ACT CFR(s): 494.110(a)(2)(ix) The program must include, but not be limited to, the following: (ix) Infection control; with respect to this component the facility must- (A) Analyze and document the incidence of infection to identify trends and establish baseline information on infection incidence; (B) Develop recommendations and action plans to minimize infection transmission, promote immunization; and (C) Take actions to reduce future incidents. This Standard is not met as evidenced by: 49321 Based on a review of records and facility’s Quality Assessment and Performance Improvement (QAPI) meeting minutes, and staff interview, it was determined that the Interdisciplinary Team (IDT) failed to identify and analyze trends, investigate all infections, develop recommendations, and take remedial actions to minimize the facility’s infection rates, specifically Peritonitis (an inflammation of the abdominal membranes, most commonly due to bacterial infection), in six of six months (October 2023 - March 2024) of QAPI meeting minutes reviewed. This deficient practice had the potential to negatively affect the health and safety of 13 Peritoneal Dialysis (PD) patients who were under the care of this facility. Findings were: - A review of facility infection report showed nine episodes of peritonitis between 5/2/23 and 2/8/24. - During a medical record review of Patient (P) #6, who was sampled for Peritonitis, it was revealed that P#6 had Peritonitis on 9/20/23, 11/30/23, and again on 1/11/24. - A review of QAPI meeting minutes from October 2023 - March 2024 revealed no documentary evidence that trends in Peritonitis were evaluated and investigated. There was no evidence that the IDT developed recommendations and take remedial actions to minimize the facility’s infection rates, specifically Peritonitis . During an interview with the PD nurse on 4/4/24 at 9:30 a.m., she stated that she covered multiple facilities.”
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Feb 5, 2025 | Complaint inspection | 2 deficiencies cited |
| Apr 5, 2024 | Standard inspection | 1 deficiency cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on May 23, 2012.
- Run for profit.
- Cited at For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. in the last three years: it didn’t meet a whole condition of Medicare’s rules for dialysis facilities.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- 2 deficiencies cited in the last three years came from inspections that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
- Doesn’t offer a shift starting at 5 p.m. or later.
- 17 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 16 dialysis facilities CMS lists in Cobb County, 14 have a star rating from CMS: 1 rated 5 of 5, 3 rated 4 of 5, 9 rated 3 of 5, 1 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.