Hearth Record

Davita Tifton Dialysis

A dialysis facility in Tifton, Georgia 31794

624 Love Ave, Tifton, Georgia 31794. (229) 382-1497.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 4 deficiencies in 1 month of the last 36. Last cited Feb 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Feb 22, 2024: a standard inspection.

4 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

4 deficiencies in 1 month of the last 36. Last cited Feb 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

4 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Feb 22, 2024: standard inspection4 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 410 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 03383 Based on observation, a review of facility Policy and Procedure and Centers for Disease Control and Prevention (CDC) Recommendations, it was determined that the Infection Control Committee failed to ensure that three of four patients (P#12, P#13, P#14) observed who held pressure to their access sites for hemostasis (stopping of the flow of blood) after dialysis, performed hand hygiene (wash hands with soap and water or use an alcohol based hand sanitizer) after glove removal and prior to leaving the facility. Failure to perform infection control techniques such as hand hygiene, increased the risk for cross contamination with the potential to expose 86 in-center hemodialysis patients who were dialyzing at this facility. Findings were: During observation in the Patient Treatment Room on 2/21/24 between 9:00 a.m. and 10:15 a.m., the following was observed: - P #12, P#13, and P#13 who were seated at Stations (S) 14, S17 and S18 respectively, held pressure to their dialysis access sites and left the facility without performing hand hygiene. - P#12, P#13, and P#13 were not reminded by the staff to wash their hands nor were offered to use hand sanitizer after glove removal. A review of Policy: 1-05-01 titled, “Infection Control For Dialysis Facilities” last revised in April 2023 stated: Hand Hygiene: 1. All teammates, Physicians and Non-Physician (NPP) will perform hand hygiene: b. Prior to gloving and immediately after removal of gloves, c. After contamination with blood or other infectious material, d. After patient and dialysis delivery system contact... g. Before touching clean areas such as supplies, supply cart and chairside keyboard/mouse. 2. Patients and caregivers will be encouraged to: a. Wash their hands and access extremity upon entering the treatment area prior to the initiation of dialysis. b. Perform hand hygiene after treatment before leaving treatment area... 2. Patients and caregivers will be encouraged to: a. Wash their hands and access extremity upon entering the treatment area prior to the initiation of dialysis. b. Perform hand hygiene after treatment before leaving treatment area... According to CDC recommendations, even with glove use, hand hygiene is necessary after glove removal because hands can become contaminated through small defects in gloves and from the outer surface of gloves during glove removal.”

    Rule V0113. Standard-level.

  • Pe - Hemodialysis Patients In View During Treatments

    The inspectors’ words, 191 words

    “PE-HD PTS IN VIEW DURING TREATMENTS CFR(s): 494.60(c)(4) Patients must be in view of staff during hemodialysis treatment to ensure patient safety, (video surveillance will not meet this requirement). This Standard is not met as evidenced by: 03383 Based on observation and staff interview, it was determined that the facility failed to ensure that two of two patients (P#15 and P#16) observed who were asleep, had their vascular access sites uncovered/visible to the staff throughout dialysis treatment, to ensure patient safety. This deficient practice could provide an opportunity for accidental needle dislodgement or a line disconnection to go undetected and could result in exsanguination (severe loss of blood). The in-center hemodialysis census was 86. Findings were: During observation in the Patient Treatment Room on 2/21/24 between 9:00 a.m. and 10:15 a.m., the following was revealed: - P#15 and P#16 who were seated at Stations 15 and 14 respectively, had their dialysis access sites completely covered with a blanket. This surveyor informed PCT QQ about the covered access sites on 2/21/24 at 9:43 a.m. PCT QQ uncovered P#16’s access site, but did not uncover P#15’s access site citing behavioral issues with patient.”

    Rule V0407. Standard-level.

  • Achieve Adequate Clearance

    The inspectors’ words, 1,201 words

    “POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 03383 Based on a review of medical records, staff interviews, and a review of facility policy, it was determined that the interdisciplinary team (IDT) failed to implement the patients’ plan of care to effectively manage patient outcomes for adequacy of dialysis [effectiveness of dialysis prescriptions to avoid symptoms of uremia (build up of toxins in the blood) - measured by Kt/V], for seven of 11 sampled patients (P#1, P#2, P#3, P#6, P#8, P#9, and P#11). The facility in-center hemodialysis census was 86. Findings were: A review of treatment flowsheets dated 2/3/24 - 2/20/24 showed the following: P#1: P#1’s dialysis prescription: Treatment time: 240 minutes (4 hours), EDW (Estimated Dry Weight): 96 kg (kilogram), BFR: 400 mL/min (milliliter per minute), DFR: 600 mL/min. On 2/8/24: - P#1’s BFR was set at 350 mL/min for the entire treatment (8:32 a.m. to 10:25 a.m). - Treatment record did not show the reason for the decreased BFR. - At 6:36 a.m., RN FF verified that P#1’s prescription matched what was being delivered during the dialysis treatment when it did not match. - At 11:29 a.m., RN GG re-verified that P#1’s prescription matched what was being delivered during the dialysis treatment when it did not. On 2/10/24: - P#1 dialyzed with a BFR of 350 mL/min from 6:32 a.m. to 7:02 a.m. and was decreased to 300 mL/min until the end of treatment at 9:48 a.m. P#2: P#2’s dialysis prescriptions: Treatment time: 195 minutes (3 hours and 15 minutes), EDW: 48 kg, BFR: 400 mL/min, DFR: 700 mL/min. On 2/5/24: - P#2 dialyzed with a DFR of 600 mL/min during the entire treatment from 10:05 a.m. to 1:12 p.m. - Treatment record did not show why P#2 dialyzed with a DFR of 600 mL/min instead of 700 mL/min as ordered. - At 1:46 p.m., RN JJ verified that the patient’s prescription matched what was being delivered during the dialysis treatment when it did not match. On 2/9/24: - P#2 dialyzed with a BFR of 350 mL/min from 10:31 a.m. to 11:01 a.m., and was decreased to 300 - 320 mL/min until the end of treatment at 1:01 p.m. - Treatment record did not show why P#2 dialyzed with a BFR of less than 400 mL/min for the entire treatment. - At 12:22 p.m., RN GG verified that the patient’s prescription matched what was being delivered during the dialysis treatment when it did not match. P#3: P#3’s dialysis prescriptions: Treatment time: 210 minutes (3 hours and 30 minutes), EDW: 65.5 kg, BFR: 350 mL/min, DFR: 600 mL/min. On 2/17/24: - P#3 dialyzed with a BFR of 300 mL/min from 7:30 a.m. to 7:43 a.m., then was decreased to 270 mL/min until the end of treatment at 9:15 a.m. - Treatment record did not show why P#3 was not dialyzed with a BFR of 350 mL/min as ordered. P#6: P#6’s dialysis prescriptions: Treatment time: 195 minutes (3 hours and 15 minutes), EDW: 74.5 kg, BFR: 400 mL/min, DFR: 600 mL/min. On 2/5/24: - P#6’s treatment started at 9:21 a.m. and was discontinued at 12:35 p.m. - Treatment record showed that the BFR was at 400 mL/min at the initiation of dialysis at 9:21 a.m. until 10:02 a.m. The BFR was decreased to 0 mL/min at 10:02 a.m. and was increased to 305 mL/min at 10:32 a.m. until the end of treatment at 12:35 p.m. - There was a lack of documented reason for not setting the BFR to 400 mL/min as ordered. - At 11:41 a.m., RN II verified that patient’s prescription matched what was being delivered during dialysis treatment when it did not match. On 2/16/24: - P#6’s treatment started at 9:03 a.m. and was discontinued at 12:20 p.m. - Treatment record showed that the BFR was 350 mL/min at the initiation of dialysis at 9:21 a.m. and remained at 350 mL/min for the entire treatment that terminated at 12:20 p.m. - There was a lack of documented reason for not setting the BFR to 400 mL/min as ordered. - At 9:05 a.m., RN FF verified that patient’s prescription matched what was being delivered during dialysis treatment when it did not match. P#8: P#8’s dialysis prescriptions: Treatment time: 195 minutes (3 hours and 15 minutes), EDW: 78 kg (kilogram), BFR: 450 mL/min, DFR: 600 mL/min. On 2/9/24: - P#8’s treatment started at 1:15 p.m. and was discontinued at 4:19 p.m. (184 minutes) - Treatment record showed that the BFR was at 350 mL/min at the initiation of dialysis at 1:15 p.m. and remained at 350 mL/min for the entire treatment that terminated at 4:15 p.m. - There was a lack of documented reason for not dialyzing P#8 at the prescribed BFR of 450 mL/min for the entire treatment. P#11: P#9’s dialysis prescriptions: Treatment time: 210 minutes (3 hours and 30 minutes), EDW: 83.5 kg (kilogram), BFR: 500 mL/min, DFR: 600 mL/min. On 2/7/24: - P#11’s treatment started at 11:26 a.m. and was discontinued at 2:07 p.m. (161 minutes) - Treatment record showed that the BFR was decreased from 500 mL/min at 12:32 p.m. to 400 mL/min and remained at this rate until treatment terminated at 2:07 p.m. - There was a lack of documented reason for not dialyzing P#11 at prescribed BFR of 500 mL/min for the entire treatment. On 2/13/24: - P#11’s treatment started at 10:52 a.m. and was discontinued at 12:55 p.m. (123 minutes) - Treatment record showed that the BFR was at 400 mL/min for the entire treatment. - At 1:20 p.m., RN GG verified that the patient’s prescription matched what was being delivered during dialysis treatment when it did not match. This was documented after the treatment was completed. - There was a lack of documented reason for not dialyzing P#11 at the prescribed BFR of 500 mL/min. On 2/15/24: - P#11’s treatment started at 10:43 a.m. and was discontinued at 1:20 p.m. (157 minutes) - Treatment record showed that the BFR was at 400 mL/min for the entire treatment. - At 11:11 am., RN FF verified that the patient’s prescription matched what was being delivered during dialysis treatment when it did not match. - There was a lack of documented reason for not dialyzing P#11 at the prescribed BFR of 500 mL/min. The Facility Administrator (FA) and Group Facility Administrator (GFA) were notified and confirmed the above findings on 2/22/24 at 4:00 p.m. A review of Policy: 1-03-08 titled, “Pre-Intra-Post Treatment Data Collection, Monitoring and Nursing Assessment” last revised October 2023 stated: Patient identity, prescription and machine settings are verified by teammate prior to initiation of treatment with the exception of blood flow rate which is verified and documented when the ordered rate is obtained after onset of treatment. The prescription components are confirmed by a licensed nurse within one (1) hour of treatment initiation along with the nursing assessment... Prescription components include but are not necessarily limited to: Blood flow rate [BFR] and dialysate flow rate [DFR] ...”

    Rule V0544. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 1,263 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 03383 Based on a review of medical records and facility policy and staff interviews, it was determined that the medical director failed to ensure that all Direct Patient Care Staff adhered to facility policy and standing orders pertaining to hypertension [elevated blood pressure (BP)] to ensure that four of four sampled patients (P#2, P#6, P#8, and P#11) who had elevated BP readings, received medical care/interventions appropriate to the patient’s dialysis needs. This failure could negatively affect the health and safety of P#2, P#6, P#8, and P#11 and the other 82 in-center hemodialysis patients who were dialyzing at this facility. Findings were: - A review of undated Medical Director’s Orders showed the following: Order A: If sBP (systolic BP - top number) > 170 or dBP (diastolic BP - bottom number) > 100 and asymptomatic will: 1) Repeat blood pressure (preferably at different site) 2) Treat with Clonidine 0.1 mg or nifedipine 60 mg x 1 dose 3) Repeat BP in 15 minutes; if still high 4) Notify MD (physician) if sBP >180 x 2 Order: B: If sBP > 170 or dBP > 100 and symptomatic (such as slurred speech, drooping, vision changes, headache, weakness in arms / legs) 1) Call MD A review of P#2, P#6, P#8, and P#11’s treatment flowsheets dated 2/3/24 - 2/20/24 showed the following: P#2: On 2/07/24: - P#2’s BP was 201/110 mm/Hg during the initiation of dialysis treatment at 9:42 a.m. - At 10:02 a.m., P#2’s BP increased to 206/111 mm/Hg. - At 10:16 a.m., P#2’s BP was 186/104 mm/Hg. - At 10:32 a.m., P#2’s BP was 188/109 mm/Hg. - At 11:02 a.m., P#2’s BP was 188/104 mm/Hg. - At 11:32 a.m., P#2’s BP was 184/104 mm/Hg. There was a lack of documented evidence that RN II performed interventions per Medical Director’s Order to administer medication and recheck BP within 15 minutes and notify MD of sBP > 180 x 2. P#6: On 2/05/24: - P#6’s BP was 181/101 mm/Hg during the initiation of dialysis treatment at 9:30 a.m. - At 10:00 a.m., P#6’s BP increased to 184/110 mm/Hg. - At 10:16 a.m., P#6’s BP was 181/98 mm/Hg. There was a lack of documented evidence that RN KK followed Medical Director’s Order to administer medication, recheck BP within 15 minutes and notify MD of sBP > 180 x 2. P#8: On 2/09/24: - P#8’s BP was 197/122 mm/Hg during the initiation of dialysis treatment at 10:49 a.m. - At 11:01 a.m., P#8’s BP was 175/108 mm/Hg. - At 11:31 a.m., P#8’s BP was 172/102 mm/Hg. There was a lack of documented evidence that PCT OO notified the licensed nurse about the patient’s high BP readings. On 2/16/24: - P#8’s BP was 206/121 mm/Hg during the initiation of dialysis treatment at 10:46 a.m. - At 11:01 a.m., P#8’s BP was 177/111 mm/Hg. - At 12:00 p.m., P#8’s BP went up to 182/102 mm/Hg. There was a lack of documented evidence that PCT OO notified the licensed nurse about the patient’s high BP readings. P#11: On 2/09/24: - P#11’s BP was 199/85 mm/Hg during the initiation of dialysis treatment at 11:37 a.m. - At 12:02 p.m., P#11’s BP was 186/86 mm/Hg. - At 12:32 p.m., P#11’s BP was 187/80 mm/Hg. - At 1:02 p.m., P#11’s BP was 199/99 mm/Hg. - At 2:02 p.m., P#11’s BP was 194/97 mm/Hg. - At 12:02 p.m., P#11’s BP was 213/90 mm/Hg. There was a lack of documented evidence that PCT OO notified the licensed nurse about the patient’s persistently high BP readings. There was a lack of documented evidence that the standing order for hypertension was followed. On 2/13/24: - P#11’s BP was 210/110 mm/Hg during the initiation of dialysis treatment at 10:53 a.m. - At 11:36 a.m., P#11’s BP was 183/90 mm/Hg. - At 12:02 p.m., P#11’s BP was 174/80 mm/Hg. - At 12:32 p.m., P#11’s BP was 199/95 mm/Hg. - At 12:54 p.m., P#11’s BP was 174/80 mm/Hg. There was a lack of documented evidence that PCT LL notified the licensed nurse about the patient’s high BP readings. There was a lack of documented evidence that the standing order for hypertension was followed. On 2/15/24: - P#11’s BP was 200/87 mm/Hg during the initiation of dialysis treatment at 10:46 a.m. - At 11:01 a.m., P#11’s BP was 202/108 mm/Hg. RN FF documented “BP high; monitor to see if it will reduce.” No recheck of BP was done until the following routine check of vital signs. There was a lack of documented evidence that the standing order was followed. - At 11:31 a.m., P#11’s BP was 190/88 mm/Hg. - At 12:01 p.m., P#11’s BP was 190/85 mm/Hg. - At 12:31 p.m., P#11’s BP was 211/111 mm/Hg; Notes showed “Patient monitored, eyes closed; patient resting”. An updated entry by PCT OO at 1:36 p.m. stated, “monitoring BP”. There was a lack of documentation that showed a licensed nurse was notified. - At 1:01 p.m., P#11’s BP was 201/99 mm/Hg. - At 1:12 p.m., P#11’s BP was 211/109 mm/Hg. - At 1:17 p.m., P#11’s BP was 194/75 mm/Hg. - There was a lack of documented evidence that PCT OO notified the licensed nurse about the patient’s extremely high BP readings. On 2/20/24: - P#11’s BP was 211/94 mm/Hg during the initiation of dialysis treatment at 10:32 a.m. - At 11:02 a.m., P#11’s BP was 175/81 mm/Hg. RN FF documented “BP high; monitor to see if it will reduce.” No recheck of BP was done until the next scheduled routine BP check. - At 11:31 a.m., P#11’s BP was 190/88 mm/Hg. - At 11:32 a.m., P#11’s BP was 190/85 mm/Hg. - At 12:01 p.m., P#11’s BP was 197/79 mm/Hg. - At 12:32 p.m., P#11’s BP was 191/84 mm/Hg. - At 1:02 p.m., P#11’s BP was 214/93 mm/Hg. - At 1:17 p.m., P#11’s BP was 220/110 mm/Hg. There was a lack of documented evidence that RN HH followed the standing orders for hypertension. A review of Policy: 1-03-08 titled, “Pre-Intra-Post Treatment Data Collection, Monitoring and Nursing Assessment” last revised October 2023, stated: Abnormal Findings: Members of the patient care team should report ANY changes in patient conditions or concerns of patient well-being immediately to the licensed nurse at any time. Blood pressure: Pre-dialysis: Systolic greater than 180 mm Hg or less than 90 mm/Hg Diastolic greater than or equal to 100 mm/Hg Blood pressure - Intradialytic: Difference of 20 mm/Hg increase or decrease from the patient’s last treatment BP reading... Blood Pressure Post Treatment: If the patient can stand: o Standing systolic BP greater than 140 mm/Hg or less than 90 mm/Hg o Standing diastolic BP greater than 90 mm/Hg or less than 50 mm/Hg If the patient is not able to stand, document reason and sitting BP: Sitting BP for patient’s that cannot stand: o Sitting systolic BP greater than 140 mm/Hg or less than 90 mm/Hg o Sitting diastolic BP greater than 90 mm/Hg or less than 50 mm/Hg 7. Document event, orders, treatment and patient response in the patient’s electronic health record. The Facility Administrator (FA) and Group Facility Administrator (GFA) were notified and confirmed the above findings on 2/22/24 between 3:15 p.m. and 4:00 p.m. The FA and GFA confirmed treatment records lacked evidence that showed standing orders related to high BP were followed by staff.”

    Rule V0715. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Feb 22, 2024Standard inspection4 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Feb 27, 2008.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
  • Doesn’t offer a shift starting at 5 p.m. or later.
  • 14 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, worse than expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 51 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 2 dialysis facilities CMS lists in Tift County, 2 have a star rating from CMS: 1 rated 2 of 5, 1 rated 1 of 5.
  • CMS rates this one 1 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

1 compared
PlaceStar rating
Tift Regional Medical Center Dialysis Center2

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.