Hearth Record

Spalding County Dialysis

A dialysis facility in Griffin, Georgia 30224

744 S. 8th Street, Griffin, Georgia 30224. (770) 467-8116.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 9 deficiencies in 1 month of the last 36. Last cited Mar 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Mar 6, 2024: a standard inspection.

9 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

9 deficiencies in 1 month of the last 36. Last cited Mar 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

9 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Mar 6, 2024: standard inspection9 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 437 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 50244 Based on observation, staff interview, and a review of facility Policy and Procedures (P& P), it was determined that the Infection Control Committee failed to ensure that eight of eight patients (P), (P#2, P#13, P#16, P#19, P#20, P#21, P#22, and P#27) observed, performed hand hygiene (washed hands or used an alcohol-based hand sanitizer), before hemodialysis treatment and after removal of contaminated gloves after holding their access sites when hemostasis (stopping of the flow of blood) was attained; and six of six patients (P#2, P#13, P#16, P#21, P#22, and P#27) observed, failed to wash their access sites prior to the initiation of their hemodialysis treatment. Failure to perform infection control techniques such as hand hygiene, increased the risk for cross contamination with the potential to expose other patients and Direct Patient Care (DPC) Staff to blood-borne pathogens in the dialysis environment. This deficient practice had the potential to negatively affect all 57 in-center hemodialysis patients who dialyzed at this facility and all 14 DPC Staff, (Nurses and Patient Care Technicians). Findings include: During observation in the Patient Treatment Room on 3/4/2024 between 8:00 a. m. and 8:30 a. m. and between 10:30 a. m. and 12:30 p. m., the following was revealed: - After each patient’s (P#2, P#13, P#16, P#21, P#22, and P#27) hemodialysis treatment was completed and their fistula needles were removed from the cannulation (needle insertion sites), these patients applied pressure to their access sites until hemostasis was attained. These patients removed their glove from their hand and exited the treatment room without performing hand hygiene. The DPC Staff did not remind them to perform hand hygiene. Prior to their hemodialysis treatment, P#2, P#13, P#16, P#19, P#20, P#21, P#22, and P#27, were observed entering the facility, weighing at the scale and going directly to their assigned hemodialysis station without performing hand hygiene. In addition, neither the patients nor the DPC Staff washed these patients’ vascular access. These findings were discussed with the Nurse Manager and the Facility Administrator on 3/4/2024 at approximately 1:00 p. m. The Facility Administrator stated that she would provide an inservice on infection control and patient vascular access care on that date. - A review of facility Policy titled, “ General Infection Control Practices” stated, “Patients wear a glove when holding sites after treatment. Patients wash their access before treatment and wash their hands before leaving the treatment area”.”

    Rule V0113. Standard-level.

  • Ic - Items Taken To Station Disposed/Dedicated Or Disinfected

    The inspectors’ words, 368 words

    “IC-IF TO STATION=DISP/DEDICATE OR DISINFECT CFR(s): 494.30(a)(1)(i) Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient. -- Nondisposable items that cannot be cleaned and disinfected (e.g., adhesive tape, cloth covered blood pressure cuffs) should be dedicated for use only on a single patient. -- Unused medications (including multiple dose vials containing diluents) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients. This Standard is not met as evidenced by: 50244 Based on observation, staff interview, and a review of facility Policy, it was determined that the Infection Control Committee failed to ensure that five of five Direct Patient Care Staff (DPC AA, DPC BB, DPC CC, DPC DD, and DPC EE) observed, practiced infection control techniques to prevent cross-contamination. This deficient practice had the potential to negatively affect the health and safety of all 57 in-center hemodialysis patients who were under the care of this facility. Findings include: During observation in the Patient Treatment Room on 3/4/2024 between 10:00 a. m. and 12:30 p.m., the following was revealed: - The clean supplies used for the purpose of preparing the dialysis station for dialysis treatment were placed into white plastic bins (clean). DPCs AA, BB, CC, DD, and EE placed these clean supply bins on top or bottom of dialysis machines (dirty), and chairs (dirty) at the patients’ Stations (S), (S1 - S4, S6 -S19). The clean supply bins were not disinfected before returning them to the common area or clean counters. - Clipboards located on top of the dialysis machines were not disinfected between patient use. Items taken to a patient’s dialysis station could become contaminated with blood and other body fluids which had the potential for cross contamination. - A review of the facility’s Policy, titled, “General Infection Control Practices”, stated: “Practice Policy: Non-disposable items are disinfected between patient use: “ These findings were discussed with the Nurse Manager on 3/4/2024 at approximately 1:00 p. m.”

    Rule V0116. Standard-level.

  • Ic - Supply Cart Distant/No Supplies In Pockets

    The inspectors’ words, 364 words

    “IC-SUPPLY CART DISTANT/NO SUPPLIES IN POCKETS CFR(s): 494.30(a)(1)(i) If a common supply cart is used to store clean supplies in the patient treatment area, this cart should remain in a designated area at a sufficient distance from patient stations to avoid contamination with blood. Such carts should not be moved between stations to distribute supplies. Do not carry medication vials, syringes, alcohol swabs or supplies in pockets. This Standard is not met as evidenced by: 50244 Based on observation, a review of Centers for Disease Control and Prevention (CDC) Recommendations, and staff interview, it was determined that the Infection Control Committee failed to ensure that five of five common clean supply carts (used to store clean supplies in the patient treatment area), were kept in a designated area and not taken to the patients’ Hemodialysis Stations (S), (S1- S4, and S6 - S20), by five of five Direct Patient Care Staff (DPCs AA, BB, CC, DD, and EE) observed, to avoid cross contamination. This deficient practice had the potential to negatively affect the health and safety of all 18 patients (P), (P#8, P#9, P#10, P#11, P#12, P#13, P#14, P#15, P#16, P#17, P#18, P#19, P#20, P#21, P#22, P#23, P#24, and P#25), who were undergoing HD treatment at the time of this observation. The facility in-center patient census was 57. Findings include: During observation in the Patient Treatment Room on 3/4/2024 between 10:00 a. m. and 12:30 p. m., all five clean supply carts were not maintained in a designated area. All five DPCs (AA, BB, CC, DD and EE) observed, moved the clean supply carts between patients at stations (S1 - S4 and S6 - S20) to obtain needed supplies for pre-dialysis, during dialysis and post-dialysis patient care. According to CDC, if a common supply cart is used, it must be kept in a designated area away from any areas where the spurting or splattering of blood or fluid may occur. These findings were discussed with the Nurse Manager at approximately 1:00 p. m. on 3/4/2024. The Nurse Manager stated that she thought that the carts could be moved if the distance between the supply carts and patient stations were maintained at a five-foot distance”

    Rule V0119. Standard-level.

  • Ic - Training And Education

    The inspectors’ words, 176 words

    “IC-TRAINING & EDUCATION CFR(s): 494.30(a)(1)(i) Infection Control Training and Education Infection control practices for hemodialysis units: intensive efforts must be made to educate new staff members and reeducate existing staff members regarding these practices. This Standard is not met as evidenced by: 50244 Based on a review of personnel records, it was determined that the facility failed to ensure that one of one License Practical Nurse (LPN II), received infection control training initially on employment and at least annually thereafter. This failure had the potential to negatively affect the health and safety of LPN II and the 57 in-center hemodialysis patients who were under the care of this facility. Findings include: - A review of personnel records revealed that LPN II’s latest training on infection control and prevention was dated 9/14/2022. - This finding was discussed with the Nurse Manager and Facility Administrator on 3/6/24 at 4:00 p.m. Both Nurse Manager and Facility Administrator acknowledged this finding and were not able to provide a more current documentary evidence of LPN II’s infection control and prevention training.”

    Rule V0132. Standard-level.

  • Ic - Aseptic Techniques For Iv Meds

    The inspectors’ words, 342 words

    “IC-ASEPTIC TECHNIQUES FOR IV MEDS CFR(s): 494.30(b)(2) [The facility must-] (2) Ensure that clinical staff demonstrate compliance with current aseptic techniques when dispensing and administering intravenous medications from vials and ampules; and This Standard is not met as evidenced by: 50244 Based on observation, a review of facility policies and procedures (P & P), a review of the Centers for Disease Control and Prevention (CDC) recommendations, and staff interview, it was determined that the infection control committee failed to ensure that two of two Registered Nurses (RN AA and RN BB), and one of one Licensed Practical Nurse (LPN FF) observed, used aseptic medication preparation techniques to prevent cross contamination in the treatment area. This breach in infection control techniques could negatively affect the health and safety of all 57 in-center hemodialysis patients who were under the care of this facility. Findings include: On 3/4/2024 at 8:40 a. m., RN AA was observed opening two single dose vials for injection. RN AA did not use alcohol pads to clean the vial stopper (or vial septum) prior to puncturing them with the needles. On 3/4/2024 at 8:48 a m., RN BB was observed drawing Heparin (anticoagulant) from a multi-dose vial. RN BB did not use alcohol pads to clean the vial stopper after opening the vial, nor prior to three re-entries into the same vial to draw up the Heparin medication. On 3/5/2024 at 8:50 a. m., LPN FF did not use alcohol pads to clean the vial stopper prior to withdrawing two separate doses of medication from the multi-dose vial. - A review of the Centers for Disease Control and Prevention (CDC) recommendations regarding Safe Injection Practices stated: Prepare injections using aseptic technique in a clean area. Disinfect the rubber septum on a medication vial with alcohol before piercing. - A review of the facility’s policy, titled, “General Infection Control Practices”, stated: “Ports of multi-dose vials will be wiped with alcohol prior to entry by a needle”. These findings were discussed with the Nurse Manager on 3/5/2024 at approximately 10:00 a. m.”

    Rule V0143. Standard-level.

  • Personnel - Training Program/Periodic Audits

    The inspectors’ words, 254 words

    “PERSONNEL-TRAINING PROGRAM/PERIODIC AUDITS CFR(s): 494.40(a) 9 Personnel: training program/periodic audits A training program that includes quality testing, the risks and hazards of improperly prepared concentrate, and bacterial issues is mandatory. Operators should be trained in the use of the equipment by the manufacturer or should be trained using materials provided by the manufacturer. The training should be specific to the functions performed (i.e., mixing, disinfection, maintenance, and repairs). Periodic audits of the operators’ compliance with procedures should be performed. The user should establish an ongoing training program designed to maintain the operator’s knowledge and skills. This Standard is not met as evidenced by: 50244 Based on a review of personnel records, it was determined that the facility failed to conduct an Annual Water, Dialysate and Machine Competency Skills checks and periodic audits to one of one Licensed Practical Nurse (LPN II) who was assigned the task of testing/validating the water quality. This deficient practice had the potential to negatively affect the health and safety of 57 in-center hemodialysis patients who were under the care of this facility. Findings include: - A review of LPN II’s Personnel record revealed that LPN II’s latest Annual Water, Dialysate and Machine Competency Skills checks and periodic audits was dated on 1/31/2023. This finding was acknowledged by the Nurse Manager and Facility Administrator on 3/6/24 at 4:00 p. m. Both Nurse Manager and Facility Administrator were not able to provide a documentary evidence of LPN II’s Annual Water, Dialysate and Machine Competency Skills checks and periodic audits since 1/31/23.”

    Rule V0260. Standard-level.

  • Pe - Building - Constructed/Maintained To Ensure Safety

    The inspectors’ words, 220 words

    “PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 50244 Based on observation and staff interview it was determined that the facility failed to provide a method for patients to summon immediate/emergency assistance, from two of two Patient Bathrooms (BR), (BR#1- in the waiting area and BR#2 - inside the Treatment Room). This deficient practice had the potential to negatively affect the health and safety of 57 in-center hemodialysis patients who were receiving hemodialysis at this facility. Findings include: During a tour of the facility with the Nurse Manager on 3/4/2024 at 8:30 a. m., it was observed that the facility lacked a functional method for patients to call for help from Patient Bathrooms, (BR #1 and BR#2). The call lights from both bathrooms produced a barely audible sound in the Dialysis Treatment area. On 3/6/2024 at 1:00 p. m., facility staff attempted to increase the volume of the alarm but without success. The alarm sound was still barely audible. The Facility Administrator confirmed these findings on 3/4/24 at 8:35 a. m. and on 3/6/24 at 1:05 p. m. and she stated that she will have both bathroom call lights fixed.”

    Rule V0402. Standard-level.

  • Continuously Monitor/Take Action/Track/Sustain Improve

    The inspectors’ words, 436 words

    “QAPI-MONITOR/ACT/TRACK/SUSTAIN IMPROVE CFR(s): 494.110(b) The dialysis facility must continuously monitor its performance, take actions that result in performance improvements, and track performance to ensure that improvements are sustained over time. This Standard is not met as evidenced by: 50244 Based on a review of the Quarterly Update of the Fiscal Year 2024 Dialysis Facility Report (DFR: A report prepared by the Centers for Medicare and Medicaid Services to provide a comparative summary of treatment patterns and patient outcomes for dialysis patients), a review of facility records, and staff interview, it was determined that the Quality Assessment and Performance Improvement (QAPI) Committee failed to track, trend, analyze, and develop plans of action for the facility’s In-Center and Peritoneal Dialysis (PD) Adequacy, PD Nutrition (Albumin - serum protein), and Transplant for six of six months (July 2023 - December 2023) of QAPI meeting minutes reviewed. This deficient practice had the potential to negatively affect the health and safety of 57 in-center hemodialysis patients and 16 PD patients, who were under the care of this facility. Findings include: A review of the Quarterly Update of the Fiscal Year 2024 DFR revealed the following: - The facility was above the United States (US) Threshold in: 1. Adequacy (Kt/V - measurement of the efficacy of a hemodialysis and peritoneal dialysis treatments) In-Center Kt/V less than (<) 1.2 was 8.4 % (Quarter 3 in QDFR). The US Threshold was 1.9 % PD Kt/V < 1.7 was 10.8 % (Quarter 3 in QDFR). The US Threshold was 5.3 %. 2. PD Nutrition - The Serum Albumin for PD (Q3 in QDFR) was 56.8 %, whereas the US Threshold was 50.5 %. - The facility was below the US Threshold for Transplantation: The % of Patients on the Active list was 2.5 %, whereas the US Threshold was 17 %. In comparison, a review of the facility’s last six months of QAPI meeting minutes from July 2023 - December 2023, revealed the following outcomes that were greater than (>) the US threshold. ICHD patients: 1. Kt/V less than (<) 1.2 for ICHD ranged from 6.0 % - 11 %. Although it improved to 6 % in November 2023, it was not sustained, it went up to 11 % in December 2023. The US threshold was 1.9%. 2. There was no record of the PD Kt/V <1.7 in the July 2023 - December 2023 QAPI Meeting minutes reviewed. During an interview with the PD Nurse Manager on 3/6/24 at approximately 3:30 p.m., the PD Nurse Manager acknowledged that the QAPI meeting minutes failed to identify specific analysis and action plans related to Kt/V <1.7 %.”

    Rule V0638. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 363 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 50244 Based on observation, staff interviews, and a review of facility Policy and Procedure (P & P), it was determined that the Medical Director failed to ensure that all Direct Patient Care (DPC) Staff - (Nurses and Patient Care Technicians), adhered to the facility’s P & P relative to patients’ access sites to remain uncovered during their hemodialysis treatment. This failure had the potential to negatively affect the health and safety of all 57 hemodialysis patients who dialyzed at this facility. Findings include: During observation in the Patient Treatment Room on 3/4/2024 at 8:10 a. m., it was revealed the access sites of patients (P), (P#1, P#2, P#3, P#4, P#5, P#6), were covered with a blanket. - The Nurse Manager was notified of the patients’ covered access sites on 3/4/2024 at 8:15 a.m.. and she proceeded to remove the blankets that covered the patients’ vascular access sites. During observation on 3/6/2024 at 10:00 a. m., it was revealed that the access sites of P#16 and P#17 were covered with blankets. - Registered Nurse (RN LL), was notified of these patients’ covered access sites on 3/6/24 at 10:03 a.m., and she removed the blankets that covered P#16’s and P#17’s access sites. - Allowing patients to cover their access sites and bloodline connections during hemodialysis treatment had the potential for accidental needle dislodgement or a line disconnection that could result in exsanguination and death within minutes. - A review of the facility’s policy, titled, “Permanent Access Care for the Hemodialysis Patient”, stated: “After initiation of treatment the access is to remain uncovered during the hemodialysis treatment. This will allow the nursing staff to monitor access at all times to ensure there is no bleeding at access site. This is to be noted on the treatment flow sheet every 30 minutes... Teach the patient the following information about access care...”

    Rule V0715. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Mar 6, 2024Standard inspection9 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Oct 3, 2001.
  • Run for profit.
  • No deficiency on record in the last three years.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis and peritoneal dialysis.
  • Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
  • 20 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • CMS lists it as independent, not owned or managed by a chain.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, worse than expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 51 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 3 dialysis facilities CMS lists in Spalding County, 3 have a star rating from CMS: 1 rated 3 of 5, 2 rated 1 of 5.
  • CMS rates this one 1 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

2 compared
PlaceStar rating
Davita Iris City Dialysis1
Usrc Griffin3

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in