Davita Effingham North Dialysis

A dialysis facility in Springfield, Georgia 31329

1451 GA Hwy 21 S, Ste A, Springfield, Georgia 31329. (912) 754-4289.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 8 deficiencies in 1 month of the last 36. Last cited Jan 2025. Most serious: Condition-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean4
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
Condition-level deficiency
For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.

What did inspectors find?

The last inspection on record was on Jan 10, 2025: a standard inspection.

8 deficiencies cited in the last three years, 2 of them at condition level, the most serious.

2 deficiencies at condition level, the more serious of CMS’s two levels

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

8 deficiencies in 1 month of the last 36. Last cited Jan 2025. Most serious: Condition-level. The last 3 years, to Oct 30, 2026.

8 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jan 10, 2025: standard inspection8 deficiencies
  • Cfc - Water And Dialysate Quality

    The inspectors’ words, 235 words

    “CFC-WATER & DIALYSATE QUALITY CFR(s): 494.40 This Condition is not met as evidenced by: 49321 Based on observation, staff interviews, and a review of policy and procedures, and manufacturer’s Directions for Use (DFU), it was determined that the facility failed to ensure that two of two Patient Care Technicians (PCT) (PCT AA and PCT BB) observed, verified the hemodialysis machine’s final dialysate conductivity (ability of the dialysate to conduct electricity) and pH (acidity), according to the manufacturer’s DFU per ANSI/AAMI RD52: 2004 guidelines. This deficient practice had the potential to negatively affect the health and safety of four of four patients who were receiving hemodialysis treatment at Station (S) 4, S5, S8 and S12 at the time of observation. Complications as minor as nausea and fatigue or as severe as metabolic acidosis (decrease in pH that could cause rapid breathing, confusion, dizziness, shortness of breath, chest pain) can result if dialysate composition is incorrect. And if conductivity is off, the effectiveness of the treatment is reduced, and patient electrolyte balance could be altered. The facility census was 23. Findings include: Cross Reference: V 250 - Failure of the facility to accurately perform independent testing of the machine’s dialysate (a solution of pure water, electrolytes and salts such as bicarbonate and sodium) pH (acidity) and conductivity (ability of the dialysate to conduct electricity) according to the Manufacturer’s DFU prior to the initiation of each patient treatment.”

    Rule V0175. Condition-level.

  • Cfc - Governance

    The inspectors’ words, 127 words

    “CFC-GOVERNANCE CFR(s): 494.180 This Condition is not met as evidenced by: 49321 Based on observations, staff interviews, a review of the manufacturer’s Directions for Use (DFU), it was determined that the Governing Body failed to demonstrate responsibility and accountability for the operations of the facility. This failure had the potential to negatively affect the health and safety of 23 in-center hemodialysis patients who were receiving hemodialysis treatment at this facility. Findings include: Cross Reference: V 250 - Failure of the facility to accurately perform independent testing of the machine’s dialysate (a solution of pure water, electrolytes and salts such as bicarbonate and sodium) pH (acidity) and conductivity (ability of the dialysate to conduct electricity) according to the Manufacturer’s DFU prior to the initiation of each patient treatment.”

    Rule V0750. Condition-level.

  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 400 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 49321 Based on observation, staff interviews, and a review of policy and procedures (P&P), it was determined that the infection control committee failed to ensure one of three Patient Care Technicians (PCT AA) observed, failed to change gloves when going from a “dirty” area/task to a “clean” area/task. This deficient practice increased the risk for cross contamination with the potential to expose Patient (P) #6 and P#2 to bloodborne pathogens in the dialysis environment. The facility census was 23. Findings include: During observation in the Patient Treatment Room on 1/8/25 at 10:00 a.m. to 12:00 p.m., the following was observed: - PCT AA wore gloves and touched the dialysis machine (dirty). Then she cleaned/disinfected P#6’s access, inserted the fistula needles, connected the needles to bloodlines (clean tasks) and started the patient’s dialysis treatment. PCT AA did not change her gloves when going from a “dirty” area/task to a “clean” area/task. - PCT AA was observed during discontinuation of P#2’s dialysis treatment. PCT AA reinfused P#2’s blood (rinsed blood back), touched the dialysis machine, sharps container, and P#2’s blanket (dirty areas/tasks). PCT AA then tore three pieces of tape (clean task) and placed them on top of the gloves, removed P#2’s needles, held pressure to establish hemostasis (stop the bleeding) and applied gauze and used the tape on her gloves to secure the gauze (clean tasks). PCT AA did not change gloves when going from a “dirty” task to a “clean” task. During an interview on 1/8/25 at 11:20 a.m., PCT AA stated that she is going so fast that sometimes she forgets to change her gloves. During an interview with the Facility Administrator on 1/10/25 at 1:00 p.m., she stated her staff are aware of clean and dirty. Stated PCT AA was not her normal staff, but she will be retrained on cross contamination before she can come back to this facility. A review of Policy 1-05-01 titled, “INFECTION CONTROL FOR DIALYSIS FACILITIES” dated April 2023 showed the following: PPE (i.e., gloves eye protection, face sheild) 7. a. Gloves should be changed when: ii, When going from a “dirty” area or task to a “clean” area or task.”

    Rule V0113. Standard-level.

  • Ic - Wear Gowns, Shields/Masks; Staff Not Eat/Drink In Tx Area

    The inspectors’ words, 308 words

    “IC-GOWNS, SHIELDS/MASKS-NO STAFF EAT/DRINK CFR(s): 494.30(a)(1)(i) Staff members should wear gowns, face shields, eye wear, or masks to protect themselves and prevent soiling of clothing when performing procedures during which spurting or spattering of blood might occur (e.g., during initiation and termination of dialysis, cleaning of dialyzers, and centrifugation of blood). Staff members should not eat, drink, or smoke in the dialysis treatment area or in the laboratory. This Standard is not met as evidenced by: 49321 Based on observation, staff interview, and a review of facility policy, it was determined that the infection control committee failed to ensure that one of one dietitian wore appropriate personal protective equipment (PPE) such as face shield, while she talked to a patient whose dialysis needles were being removed, during which spurting or spattering of blood could occur. Findings include: During observation in the Patient Treatment Room on 1/8/25 at 10:00 a.m. to 12:00 p.m., the following was observed: - Patient (P) #6 was seated at Station (S) 3. Patient Care Technician (PCT) AA removed both arterial and venous needles from P#6’s access sites (during which spurting or spattering of blood could occur) while the dietitian stood on the side of the patient’s treatment chair and talked to P#6. The dietitian did wear a face shield to protect herself when spurting or spattering of blood might occur. During an interview on 1/8/25 at 10:26 a.m., the dietician stated that she thought a face shield was warranted only when the patient’s treatment was started and when the treatment was completed. A review of Policy 1-05-01 titled, “INFECTION CONTROL FOR DIALYSIS FACILITIES” dated April 2023, showed the following: PPE (i.e., gowns, gloves, eye protection, face shield) 5. Appropriate PPE will be worn whenever there is the potential for contact with body fluids, hazardous chemicals, contaminated equipment and environmental surfaces, for example, patient areas.”

    Rule V0115. Standard-level.

  • Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts

    The inspectors’ words, 485 words

    “IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 49321 Based on observation, staff interview, and a review of policy and procedures, it was determined that the Infection Control Committee failed to ensure that two of three Patient Care Technicians (PCT AA and PCT BB) observed, failed to perform disinfection of equipment after use and prior to returning it to the clean/designated area. This deficient practice increased the risk for cross contamination with the potential to expose 23 patients and staff to bloodborne pathogens in the dialysis environment. Findings include: During observation in the Patient Treatment Room on 1/8/25 at 10:00 a.m. to 12:00 p.m., the following was observed: - PCT AA used the Myron-L Meter at Station (S) 1. The Myron-L Meter was placed on top of the dialysis machine (dirty). When finished, the Myron-L Meter was placed back in the clean/designated area. The meter was not cleaned or disinfected before it was returned in the clean/designated area. - PCT BB used the Myron-L Meter at S8. The Myron-L Meter was placed on top of the dialysis machine. When finished, the Myron-L Meter was placed back in the clean/designated area. The meter was not cleaned or disinfected before it was returned in the clean/designated area. During an interview on 1/8/25 at 10:25 a.m., PCT BB acknowledged that she did not clean the Myron-L Meter before putting it back in the clean area. During an interview on 1/8/25 at 10:35 a.m., PCT AA was unsure if the meter should be cleaned because she stated the dialysis machine was clean. During an interview with the Facility Administrator on 1/10/25 at 1:00 p.m., she stated PCT AA was not her normal staff, but she will be retrained on cross contamination. A review of Policy 1-05-01 titled, “INFECTION CONTROL FOR DIALYSIS FACILITIES” dated April 2023 showed the following: DISINFECTION 12. Cleaning and/or disinfection of equipment and work surfaces will be performed as soon as possible following exposure to blood or other potentially infectious materials (i.e. used or brought into the station) and prior to returning to clean/designated area or removal from treatment area.”

    Rule V0117. Standard-level.

  • Ic - Hbv - Vaccinate Patients & Staff

    The inspectors’ words, 530 words

    “IC-HBV-VACCINATE PTS/STAFF CFR(s): 494.30(a)(1)(i) Hepatitis B Vaccination Vaccinate all susceptible patients and staff members against hepatitis B. This Standard is not met as evidenced by: 49321 Based on a review of facility records, a review of personnel file, and staff interview, it was determined that the facility failed to ensure that three of five patients (P) sampled (P#1, P#2, and P#5) and one of one Medical Director, who were susceptible to hepatitis B virus, were vaccinated against hepatitis B. Findings include: A review of the facilities “Vaccination and Surveillance Report” revealed the following: - Hepatitis B surface Antibody (HBsAb) = A test measures the level of antibodies in blood that body produces to fight the hepatitis B virus (HBV). - HBsAb 10 or greater = Immunity - HBaAb less than 10 means the person is susceptible - P#1 was tested for HBsAb on 11/8/24 and resulted 7. P#1 received the Hep B vaccine on 10/16/24, 9/18/24/, and 8/23/24 outside of the facility and was scheduled to received Engerix B vaccine (Hepatitis B vaccine) at the facility on 11/22/24. The dose was not given. There was no declination note in the patient’s chart. - P#2 was tested for HBsAb on 11/8/24 and resulted 4. Last Engerix 40 mg vaccine dose was given on 6/22/22. There was no counseling or declination in the patient’s chart. - P#5 was tested for HBsAb on 10/18/24 and resulted 3. Last Engerix 40 mg vaccine dose was given on 4/24/24. There was no counseling or declination noted in the patient’s chart. - The Medical Director’s last HBsAb was drawn on 3/29/21. The result was reactive and did not have a numeric value. There was a lack of Hepatitis B Core antibody, or a Hepatitis B surface Antigen drawn nor a declination in MD’s personnel file. During an interview with the Facility Administrator on 1/10 25 at 1:00 p.m., she acknowledged that staff should have been monitoring the patients’ Hep B vaccinations more closely. She also stated the Medical Directors office staff only offered the labs that were drawn 3/29/21. A review of Policy: 1-05-02 titled, “Hepatitis B SURVEILLANCE, VACCINATION, INFECTION CONTROL MEASURES AND ISOLATION GUIDANCE” last revised April 2024 showed the following: 13. Test all vaccinated patients for HBsAb one (1) to two (2) months after the last dose of full vaccine series (adequate response is defined as greater than or equal (>) 10mIU/mL. a. If hepatitis B surface antibody (HBsAb) is less than (<) 10 mIU/mL, consider the patient susceptible, revaccinate with additional full series, and retest for HBsAb one (1) to two (2) months after the last dose of the second series. A review of Policy: 4-06-03 titled, “Teammate Hepatitis B Monitoring and Follow-Up Guidance “ with latest revision date of April 2024 showed: 2. Teammates providing evidence of hepatitis B surface antibodies of 10 mIU/mL or greater upon hire will be considered immune and will not require initial or ongoing testing. Acceptable documentation of anti-HB titers will be either a copy of: 1. An official laboratory results 2. Or a prior employer’s health monitor form Documentation must contain testing dates and NUMERIC titer results. Results documented as only positive will not be accepted.”

    Rule V0126. Standard-level.

  • Dialysate Proportioning - Monitor Ph/Conductivity

    The inspectors’ words, 1,019 words

    “DIALYS PROPORT-MONITOR PH/CONDUCTIVITY CFR(s): 494.40(a) 5.6 Dialysate proportioning: monitor pH/conductivity It is necessary for the operator to follow the manufacturer’s instructions regarding dialysate conductivity and to measure approximate pH with an independent method before starting the treatment of the next patient. This Standard is not met as evidenced by: 49321 Based on observation, staff interviews, and a review of policy and procedures, and manufacturer’s Directions for Use (DFU), it was determined that the facility failed to ensure that two of two Patient Care Technicians (PCT) (PCT AA and PCT BB) observed, verified the hemodialysis machine’s final dialysate conductivity (ability of the dialysate to conduct electricity) and pH (acidity), according to the manufacturer’s DFU per ANSI/AAMI RD52: 2004 guidelines. This deficient practice had the potential to negatively affect the health and safety of four of four patients who were receiving hemodialysis treatment at Station (S) 4, S5, S8 and S12 at the time of observation. Complications as minor as nausea and fatigue or as severe as metabolic acidosis (decrease in pH that could cause rapid breathing, confusion, dizziness, shortness of breath, chest pain) can result if dialysate composition is incorrect. And if conductivity is off, the effectiveness of the treatment is reduced, and patient electrolyte balance could be altered. The facility census was 23. Findings include: During observation in the Patient Treatment Room on 1/8/25 between 10:00 a.m. and 12:00 p.m., the following was observed: - PCT AA was observed during machine set-up at S5. When finished, she summoned a patient from the waiting area and conducted the pre-treatment assessment and vital signs. Meanwhile, PCT CC (who was called in to work/help out) went to S5 and offered to test/verify dialysate pH and conductivity. PCT AA stated she has done them. However, this surveyor’s attention was focused exclusively on the machine set-up procedure and initiation of dialysis on the patient in S5, did not observe any staff tested/verified the final dialysate of the machine at S5. PCT AA initiated the patient’s dialysis treatment without checking the dialysate pH and conductivity. This was confirmed by PCT CC on 1/8/25 at 10:18 a.m. During an interview on 1/8/25 at 10:25 a.m., PCT AA was asked by this surveyor to demonstrate how she checked the pH and conductivity of the dialysis machine. PCT AA removed the blue hanson from the dialyzer and allowed the dialysate to flow into the meter cup on the Myron-L Meter. The meter was then placed on top of the dialysis machine. PCT AA inserted the plunger, did not agitate the sample, pressed the black button, and documented the result. PCT AA then placed an RPC K100-0117CT E-Z pH test strip inside the Myron -L Meter cup, removed the strip from the cup, and immediately compared the strip to the color chart on the RPC bottle. PCT AA did not wait between 20 and 25 seconds to compare test results to the color scale per manufacturer’s DFU. PCT AA was asked how many times the Myron-L Meter should be rinsed with dialysate before reading the conductivity. PCT AA stated I have never rinsed the Myron-L Meter with dialysate. When asked about testing for pH, PCT AA stated she dipped the RPC strip and compared it immediately. Stated she never knew she had to wait before reading the result. - PCT BB was observed as she checked the dialysis machine’s pH and conductivity at S8. PCT BB retrieved dialysate from the blue Hanson with a syringe. She then poured the dialysate into the meter cup, inserted the plunger, pressed the black button, and documented her reading. She then inserted an RPC K100-0117 E-Z pH test strip inside the Myron-L meter cup, removed the strip from the cup, and immediately compared the strip to the color chart on the RPC bottle and did not wait for the color to develop per manufacturer’s DFU. During an interview on 1/8/25 at 10:35 a.m., PCT BB was asked how many times should the Myron-L meter be rinsed with dialysate before a conductivity reading was taken, PCT BB said she was educated to put the dialysate in the meter cup and read the conductivity. She also admitted that sometimes, when rushing, she does not use the Myron-L meter. When asked how many seconds she should wait before comparing the RPC strips to the color chart, she stated she did not know. . The Bio-Medical Technician (BMT) and the Acting Facility Administrator were notified of the findings on 1/8/25 at 10:45 a.m. The BMT stated staff would be immediately retrained on correctly using the RPC K100-0117CT E-Z pH test strips and the Myron-L Meter. A review of Policy: 1-03-02 titled, “Testing pH and Conductivity of Proportioned Dialysate and Verification of Temperature of Proportioned Dialysate” revised October 2024 showed: - Manual pH testing must be performed prior to each patient’s treatment. A review of the RPC K100-0117CT E-Z Chek 6.8- 8.5 pH Test Strips’ manufacturer’s DFU showed the following: Instructions for use 3. Dip or wet the strip pad for one second with fresh solution to be tested. 4. Briskly shake off excess solution. Compare test results to the color scale on the bottle between 20 and 25 seconds. Retest if the results are not read within the 25-second time frame. A review of the “Myron L Conductivity Meter (D-1) skills checklist” dated May 2023 showed the following: Operation of the Myron L Conductivity Meter 3. Fill the meter cell cup with sample so upper electrode is immersed, insert plunger. Agitate sample with plunger by moving up and down 3 to 4 times and then discard sample. Perform these steps at least 3 times. 4. Obtain another proportioned dialysate sample, fill the meter, drop the plunger in the solution, and press the black button. When the pointer stops, immediately read and release the button. Repeat this step twice, press the Read/Check button, and document the conductivity reading. According to ANSI/AAMI RD52: 2004 Section 5.6, “Dialysate Proportioning”, it is necessary for the operator to follow the manufacturer’s instructions regarding dialysate conductivity and to measure approximate pH with an independent method before starting the treatment of the next patient.”

    Rule V0250. Standard-level.

  • Pe - Building - Constructed/Maintained To Ensure Safety

    The inspectors’ words, 333 words

    “PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 49321 Based on observation and staff interview, it was determined that the facility failed to ensure that the building in which dialysis services were provided, was maintained free from damage and defects to ensure the safety of the patients and staff. Failure to maintain the integrity of all surfaces could hinder effective cleaning and disinfection of the surfaces, thus providing a potential for microbial growth. These environmental concerns were observed in one of one Patient Treatment Room and one of one Supply Room. The facility census was 23. Findings include: During a tour of the facility on 1/8/25 from 12:00 p.m. to 1:00 p.m. with the Biomedical Technician, the following was observed: In the Patient Treatment Room: - The drywall behind the wall box and drain (connections for the dialysis machine to receive acid, base concentrate, treated water, and dispose of waste products) at Station (S) 2 had approximately 3 feet of rust colored substance above the base molding. The floor around this area was wet. - There were two buckled floor tiles around the support beam between S10 and S11 that were separated from the tile bed. Dirt particles were present underneath the lifted tiles. In the Supply Room: - The floor was uneven with noticeable grooves all over the entire floor. - There were four large supply racks that were stored against the wall. Underneath the supply racks showed dust and dirt particles. During an interview with the Biomedical Technician on 1/8/25 at 1:15 p.m., he stated the wall at S2 had been stained for a while and the floor is wet because the dialysis machine is leaking. He also stated that he put in a ticket for the Supply Room floor to be resurfaced with Epoxy and was waiting for an estimate.”

    Rule V0402. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jan 10, 2025Standard inspection8 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Apr 20, 1999.
  • Run for profit.
  • Cited at in the last three years: it didn’t meet a whole condition of Medicare’s rules for dialysis facilities.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, worse than expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 2 dialysis facilities CMS lists in Effingham County, 2 have a star rating from CMS: 2 rated 3 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

1 compared
PlaceStar rating
Fresenius Medical Care Rincon3

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.