Hearth Record

Fresenius Medical Care Clayton County

A dialysis facility in Riverdale, Georgia 30274

181 Upper Riverdale Rd, Riverdale, Georgia 30274. (770) 996-9660.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 5 deficiencies in 2 months of the last 36. Last cited Feb 2025. Most serious: Condition-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean4
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
Condition-level deficiency
For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.

What did inspectors find?

The last inspection on record was on Feb 19, 2025: a complaint inspection.

5 deficiencies cited in the last three years, 2 of them at condition level, the most serious.

2 deficiencies at condition level, the more serious of CMS’s two levels

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

5 deficiencies in 2 months of the last 36. Last cited Feb 2025. Most serious: Condition-level. The last 3 years, to Oct 30, 2026.

5 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Feb 19, 2025: complaint inspection4 deficiencies
  • Cfc - Responsibilities Of The Medical Director

    The inspectors’ words, 127 words

    “CFC-RESPONSIBILITIES OF THE MEDICAL DIRECTOR CFR(s): 494.150 This Condition is not met as evidenced by: 32734 Based on a review of records and facility Policy and Procedures (P & P), and staff interviews, it was determined that the Medical Director failed to demonstrate accountability for the clinical operations of the facility to ensure the delivery of safe patient care. This failure resulted in Patient #1’s exsanguination during dialysis treatment. The facility had 108 patients who were receiving hemodialysis treatment at this facility. Findings include: Cross Reference: V 715 - Failure of the Medical Director to ensure that two direct patient care staff (Licensed Practical Nurse [LPN] AA and Patient Care Technician [PCT] AA) adhered to P & P relative to patient assessment and monitoring during dialysis treatment.”

    Rule V0710. Condition-level. From a complaint.

  • Cfc - Governance

    The inspectors’ words, 176 words

    “CFC-GOVERNANCE CFR(s): 494.180 This Condition is not met as evidenced by: 32734 Based on record review, and staff interviews, it was determined that the Governing Body failed to demonstrate responsibility and accountability for the operations of the facility. This deficient practice had the potential to negatively affect the health and safety of 108 in-center hemodialysis patients who were receiving dialysis treatment at this facility. Findings include: Cross-References: V 715 - Failure of the Medical Director to ensure that two direct patient care staff (Licensed Practical Nurse [LPN] AA and Patient Care Technician [PCT] AA) adhered to P & P relative to patient assessment and monitoring during dialysis treatment. V 757 - Failure of the Governing Body to ensure that the facility had adequate number of qualified staff to meet the needs of all patients and provide safe patient care; and to be in compliance with the minimum State required staffing ratios of one licensed and qualified nurse for every 12 patients who were receiving dialysis care and one qualified patient care giver for every four patients.”

    Rule V0750. Condition-level. From a complaint.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 698 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 32734 Based on a review of records and facility Policy and Procedures (P & P), and staff interviews, it was determined that the Medical Director failed to ensure that staff adhered to P & P relative to patient assessment and monitoring during dialysis treatment, as evidenced by failure of two direct patient care staff (Licensed Practical Nurse [LPN] AA and Patient Care Technician [PCT] AA) to monitor assigned patients per P & P. This failure resulted in Patient (P) #1’s unresponsiveness due to exsanguination (a substantial blood loss that can be fatal) during dialysis treatment. The facility had 108 patients who were receiving hemodialysis treatment at this facility. Findings include: A review of the facility’s Adverse Occurrence Reports Log revealed the following: 9/14/24 - Needle dislodgement - blood loss < (less than) 100 cc; No treatment given. 9/16/24 - Needle dislodgement - blood loss <100 cc; No treatment given. 11/8/24 - Needle dislodgement - blood loss <100 cc; No treatment given. 1/20/25 - Needle dislodgement - blood loss >500 cc; Patient (P) #1 was sent to the hospital for evaluation and treatment. A review of P#1’s treatment sheet dated 1/20/25 revealed the following: - P#1’s dialysis treatment was initiated at 11:13 a.m., by Patient Care Technician (PCT) AA and documented “without problem”. P#1’s blood pressure (BP) was 147/89 mm/Hg (millimeters of mercury) and his pulse rate (PR) was 64. “Denies complaints” was also documented. - At 11:30 a.m., P#1’s BP was 131/83 mm/Hg with a PR of 59. “Denies complaints” was documented by PCT AA. NOTE: Every 30 minutes monitoring of BP, PR, general observation/mental status, access inspection per P & P that was due at 12:00 p.m., was missed. - At 12:15 p.m., “Ended” was documented. There was a lack of documented BP, PR, observation, or other notes. - At 1:18 p.m., the following was documented by Licensed Practical Nurse (LPN) AA under Multidisciplinary Notes: “12:15 pt (Patient) venous needle noted to be dislodged, not responding. 500 cc saline given. bp 108/76 pulse 38. Approximately 600 cc of blood loss. Pt saline 140/107 pulse 68. 911 called. (Named) NP (Nurse Practitioner) on treatment floor. Informed. Family contacted of transport to er (Emergency Room)” [sic]. During an interview on 2/19/25 at 4:12 p.m., when asked about the blood loss incident that occurred on 1/20/25, LPN AA stated, “It gets busy in that area (referred to Pod 7, where P#1 was seated at). The nurse was assigned to two patients for total care and conducted assessments and prepared/administered medications on the remaining eight patients. I saw blood on the machine and we did all our normal steps with blood loss and sent the patient to the hospital. Patient is aphasic (has difficulty speaking/communicating) and moves around a lot. The patient’s sister was supposed to come sit with him.” During a telephonic interview on 2/19/25 at 4:24 p.m., PCT AA stated she was the tech assigned to P#1. Stated “I remember getting him situated. He was my second patient. I was putting on my fourth patient when the nurse told me about the blood. We thought it was coming from the patient who was seated next to him. I was putting on (initiating treatment) another patient and I missed taking the 12:00 p.m. BP on him. We have 15 minutes to put the patient on the machine. Everything happened so fast”. A review of facility policy titled, “Patient Assessment and Monitoring” published 5/1/23 Version 4 showed the following: Page 4: During Treatment: Obtain blood pressure and pulse rate every 30 minutes or more as needed but not to exceed 45 minutes or per state regulations. Page 5: General Observation/Mental Status: Access- Observe connections are secure and visible. Ensure access remains uncovered throughout treatment; No bleeding or infiltration noted. During the exit interview on 2/19/25 at 5:45 p.m., the Facility Administrator acknowledged the above findings.”

    Rule V0715. Standard-level. From a complaint.

  • Staff # & Ratio Meet Patient Needs

    The inspectors’ words, 1,299 words

    “GOV-STAFF # & RATIO MEET PT NEEDS CFR(s): 494.180(b)(1) The governing body or designated person responsible must ensure that- (1) An adequate number of qualified personnel are present whenever patients are undergoing dialysis so that the patient/staff ratio is appropriate to the level of dialysis care given and meets the needs of patients; This Standard is not met as evidenced by: 32734 Based on observation, a review of records, interviews, and a review of minimum state required staffing ratios, it was determined that the Governing Body failed to ensure the facility had adequate number of qualified staff to meet the needs of all patients as evidenced by a lack of at least one licensed and qualified nurse (who was not counted as a dialysis care giver in the staff-to-patient ratio of one dialysis care giver to four patients), who was readily available to provide nursing care, take charge, and deal with unexpected complications of dialysis, for every 12 patients who were receiving dialysis care; and that each care giver was not assigned more than four patients each shift. This deficient practice had the potential to cause a delay in monitoring patients for issues such as fluid overload (an excessive amount of fluid in the body), changes in vital signs, access sites, or problems with the dialysis equipment. Additionally, insufficient staffing could mean slower responses to alarms, missed complications including but not limited to intradialytic hypotension (sudden drops in blood pressure which can occur when fluid is removed too rapidly), arrhythmias (irregular heartbeat), and other medical issues and emergencies related to hemodialysis. The facility had 108 incenter hemodialysis patients. Findings include: During observation in the Patient Treatment Room on 2/19/25 between 10:40 a.m. and 1:00 p.m., the following was revealed: - There were two Registered Nurses (RN AA and RN BB), two Licensed Practical Nurses (LPN AA and LPN BB), three Patient Care Technicians (PCT BB, PCT CC, and the Facility Administrator, who is also a PCT) who provided direct patient care on 2/19/25. - There were 30 patients who were scheduled to dialyze on the first and second shifts. However, due to hospitalizations and other reasons, there were 26 patients who dialyzed on the first shift and 25 patients on second shift. A review of the staff/patients assignment sheet dated 2/19/25 showed the following: First shift: - PCT AA who was originally assigned to care for patients at Station (S) 1, S2, S3, and S4 called out. - The Facility Administrator cared for six patients who were seated at S1, S2, S3, S4, S18, and S29. - PCT BB was assigned and cared for three patients in S20, S21, and S23. - RN AA functioned as a dialysis care giver (total care) to two patients in S24 and S25. In addition, RN AA was also assigned to perform all nursing duties such as conducting pre and post nursing assessments, preparation and administration of all medications, addressing patient complaints, physician notification, dealing with unforeseen complications of dialysis/medical issues, and emergency situations that could arise during dialysis treatment for seven patients in S1, S2, S3, S4, S20, S21, and S23, who were assigned to PCTs (Facility Administrator and PCT BB). - RN BB functioned as a dialysis care giver for two patients in S26 and S27. In addition, RN BB was also assigned to take charge and perform all nursing care and duties such as pre and post nursing assessments, preparation and administration of all medications, addressing patient complaints, dealing with unforeseen complications of dialysis/medical issues, and emergency situations that could arise during dialysis treatment for eight patients in S5, S6, S7, S8, S18, S19, S28, and S29, who were assigned to PCTs (PCT CC and Facility Administrator). - PCT CC was assigned to care for six patients at S5, S6, S7, S8, S19, and S28. - LPN AA was assigned to care for five patients at Station Buffer Zone (SBZ) 11, SBZ12, SBZ 13, SBZ15, and SBZ17. - LPN BB functioned as a dialysis care giver for two patients in SBZ16 and SBZ30. In addition, LPN BB was also assigned to assist with nursing duties for five other patients in SBZ11, SBZ12, SBZ 13, SBZ15, and SBZ17. - Furthermore, RN AA, RN BB, and LPN BB were also responsible for the initiation and termination of dialysis treatment, assessment and performing catheter care for patients with a central venous catheter (CVC - a thin, flexible tube inserted into a large vein near the heart to provide access for hemodialysis), who were assigned to PCTs. A review of staff/patients assignment sheets from February 10, 2025 through February 18, 2025 revealed the following: On 2/10/25: There were 29 patients scheduled on the first shift and 27 patients on second shift. There were six PCTs, two LPNs and one RN. On 2/11/25: There were 30 patients scheduled on the first shift and 25 patients on second shift. There were six PCTs, two LPNs and one RN. On 2/12/25: There were 30 patients scheduled on the first shift and 29 patients on second shift. There were seven PCTs, two LPNs and one RN who were scheduled to work. However, there were only five PCTs, two LPNs and one RN who worked due to call outs. The patient’s appointments were not adjusted accordingly, to ensure a safe patient care environment. On 2/13/25: There were 30 patients scheduled on the first shift and 27 patients on second shift. There were seven PCTs, two LPNs and one RN. On 2/14/25: There were 30 patients scheduled on the first shift and 28 patients on second shift. There were six PCTs, two LPNs and one RN. On 2/15/25: There were 26 patients scheduled on the first shift and 23 patients on second shift. There were five PCTs, two LPNs and one RN. On 2/17/25: There were 30 patients scheduled on the first shift and 29 patients on second shift. There were six PCTs, two LPNs and one RN. On 2/18/25: There were 30 patients scheduled on the first shift and 24 patients on second shift. There were six PCTs, two LPNs and one RN. - When there were three nurses on the schedule, each nurse functioned as a dialysis care giver and provided total patient care for two patients. In addition, each nurse was assigned to take charge, perform all nursing duties and deal with unforeseen complications of dialysis/medical issues, and emergency situations that could arise during dialysis treatment for eight patients who were assigned to PCTs. - When four nurses were scheduled to work, the fourth nurse functioned as a dialysis care giver for at least four patients. During an interview on 2/19/25 at approximately 12:40 p.m., Patient (P) (P#2) who was seated at S16 stated that the facility is sometimes short-staffed, but the staff do the best they can. An interview with the Facility Administrator on 2/19/25 at 11:45 a.m. revealed that direct care staffing was an issue. The Facility Administrator stated that on some days, she was part of staffing as a PCT throughout the day. During an interview on 2/19/25 at 12:50 p.m., the Charge Nurse (CN) stated that staffing usually consisted of two LPNs, two staff RNs and six PCTs. The CN usually did not have a patient assignment. However, the facility had been short-staffed for about two to three months and was being assisted by float staff from other facilities. Stated that it was overwhelming at times for the RNs and LPNs to be assigned to the Nurse Pod of two patients per shift, and to be responsible for eight other patient’s medications and nursing assessments. In addition, cross reference V 715 - Failure of the Medical Director to ensure all staff adhered to P & P relative to patient assessment and monitoring during dialysis treatment. This failure resulted in exsanguination during dialysis treatment.”

    Rule V0757. Standard-level. From a complaint.

Aug 22, 2024: standard inspection1 deficiency
  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 478 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 03383 Based on observation and staff interviews, it was determined that the facility failed to maintain a safe environment as evidenced by the malfunctioning bicarbonate (bicarb) alarm loudly sounding in the treatment area; and the presence and broken mechanisms and/or torn leather upholstery on seven of 31 patient treatment chairs (at Station (S) 5, S15, S16, S18, S19, S26, and S30) in the patient treatment area. This deficient practice could hinder effective cleaning/disinfection and could have a negative effect on the health and safety of 110 patients who were receiving dialysis treatment at this facility. Findings include: 1. During observation in the patient treatment area on 8/19/24 at 12:14 p.m. with the Charge Nurse, the following was revealed: - During a tour of the treatment area, a loud shrill alarm was constantly sounding in the patient treatment area. The charge nurse indicated on 8/19/24 at 12:15 p.m., that it is the bicarb level indicator alarming. During an interview on 8/19/24 at 12:20 p.m., Licensed Practical Nurse (LPN) KK stated the bicarb system is broken and it’s been like this for the last month. During observation in the water treatment room on 8/20/24 at 3:53 a.m., Patient Care Technician (PCT) AA was observed mixing bicarb and revealed that the mixer motor is broken, and she must hold the button down on bicarb system for 10 minutes while bicarb is mixing and 10 to 15 minutes while bicarb is transferred over to the holding/distribution tank. During an interview on 8/20/24 at 8:26 a.m., the Biomedical Area Manager (BAM) revealed the bicarb system was alarming because staff allowed the bicarb system to flood (overflow); this has occurred at least three times. The manufacturer of the bicarb system had been at this facility several times and attempted to repair the bicarb system but made it worse. A new bicarb system is being built and it will probably take another month before it is completed. The BMA disconnected the alarm in the patient treatment area to stop the alarm from sounding on 8/21/24 at 3:00 p.m. The bicarb alarm is inoperable. 2. During observation in the patient treatment area on 8/19/24 between 3:31 p.m. and 4:00 p.m., the following was revealed: - Broken mechanisms and/or torn leather upholstery was observed in seven of 31 patient treatment chairs at S 5, S15, S16, S18, S19, S26, and S30 in the patient treatment area. - Registered Nurse (RN) NN confirmed the above findings on 8/19/24 at 3:50 p.m. The Director of Operations was informed about the above findings during exit interview on 8/22/24 at 1:15 p.m.”

    Rule V0403. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Feb 19, 2025Complaint inspection4 deficiencies cited
Aug 22, 2024Standard inspection1 deficiency cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Feb 12, 1998.
  • Run for profit.
  • Cited at in the last three years: it didn’t meet a whole condition of Medicare’s rules for dialysis facilities.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • 4 deficiencies cited in the last three years came from inspections that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis and peritoneal dialysis.
  • Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
  • 31 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, worse than expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, worse than expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 4 of 5 in CMS’s survey of in-center hemodialysis patients (44 interviews, Oct 18, 2024 to Jul 11, 2025): 60% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 54 of 5

How does it compare nearby?

  • Of the 9 dialysis facilities CMS lists in Clayton County, 9 have a star rating from CMS: 3 rated 3 of 5, 3 rated 2 of 5, 3 rated 1 of 5.
  • CMS rates this one 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.