Davita Brunswick Dialysis
A dialysis facility in Brunswick, Georgia 31525
53 Scranton Connector, Brunswick, Georgia 31525. (912) 264-8657.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 3 deficiencies cited in the last three years
- 24 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Aug 28, 2024: a standard inspection.
3 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
3 deficiencies in 1 month of the last 36. Last cited Aug 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Aug 28, 2024: standard inspection3 deficiencies
-
Dialysis Emergency Equipment
The inspectors’ words, 717 words
“Dialysis Emergency Equipment CFR(s): §494.62(b)(9) Condition for Coverage: [(b) Policies and procedures. The dialysis facility must develop and implement emergency preparedness policies and procedures, based on the emergency plan set forth in paragraph (a) of this section, risk assessment at paragraph (a)(1) of this section, and the communication plan at paragraph (c) of this section. The policies and procedures must be reviewed and updated at least every 2 years. At a minimum, the policies and procedures must address the following:] (9) A process by which the staff can confirm that emergency equipment, including, but not limited to, oxygen, airways, suction, defibrillator or automated external defibrillator, artificial resuscitator, and emergency drugs, are on the premises at all times and immediately available. This Standard is not met as evidenced by: 33921 Based on observation, staff interview, and a review of the Food and Drug Administration (FDA) recommendations and manufacturer’s Directions for Use (DFU), it was determined that the facility failed to ensure that expired medications in one of one Emergency Crash Cart, and in one of one Medication Refrigerator, were removed and not made available for use. This deficient practice had the potential to negatively affect the health and safety of 37 in-center hemodialysis (ICHD) patients, 29 Peritoneal Dialysis (PD) patients, and one Home Hemodialysis (HHD) patient, who were under the care of this facility. Findings include: During a tour of the facility with the Facility Administrator on 8/26/24 between 10:50 a.m and 11:30 a.m., the following medications had expired and some had no date of when these were opened/accessed, thus these were not suitable for use. In the Emergency Crash Cart: 1. one vial of Ondansetron Injection 4 mg/2 mL (for nausea and vomiting) - there was no date when it was opened/accessed and no initial of the person who opened/accessed it. 2. one vial of Diphenhydramine 50 mg/mL (antihistamine) - there was no date when it was opened/accessed and no initial of the person who opened/accessed it. In the In-Center Medication Refrigerator: 1. one opened/accessed multidose vial of Epogen 20,000 units (for the treatment of Anemia) - had no date when first accessed and no initial of the person who opened/accessed it. According to the manufacturer’s direction for use (DFU) - regarding storage of Epogen: - Throw away multiple-dose vials of Epogen no later than 21 days from the first day that you put a needle into the vial. Keep refrigerated. 2. one vial of accessed/opened Tubersol (Tuberculin Purified Protein Derivative, is indicated to aid diagnosis of tuberculosis infection (TB) in persons at increased risk), was dated (accessed) 4/2/24 with no initial of the person who opened/accessed it. According to the manufacturer’s DFU for Tubersol and FDA, opened/used Tubersol should be discarded after 30 days. 3. three vials of Flucelvax (influenza vaccine) and 10 prefilled syringes of Flucelvax, expired 6/2024. According to the manufacturer’s DFU regarding Flucelvax: - If the expiration date on the vial is just a month and a year (e.g., “08/23”), then the vaccine should not be used after the last day of August 2023. If the expiration day is a specific day (e.g., “8/15/23”), then the vaccine should not be used after that date. According to FDA recommendation dated 2/8/21, drugs’ expiration dates reflect the time period during which the product is known to remain stable, which means it retains its strength, quality, and purity when it is stored according to its labeled storage conditions. Several potential harms may occur from taking an expired medication or using expired supplies. Once the expiration date has passed there is no guarantee that the medicine or supplies will be safe and effective. A review of facility Policy: 1-06-01, titled, “Medication Policy” with latest revision date of October 2023, stated: 13. All open or unopened medication packages (i.e. vials, ampules, etc.) are stored according to the manufacturer’s directions. Do not use any medication that has been stored improperly or has expired. 29. Medications containing a preservative must be discarded 28 days after opening or accessed (e.g., needle punctured), unless the manufacturer specifies a different (shorter or longer) date... Each vial is labeled with the initials of the person opening the vial and the expiration date... ... Epogen multidose vials must be discarded 21 days after opening or accessed... 31. Medications are ordered and replaced prior to expiration...”
-
Ic - Staff Education Re Catheters/Catheter Care
The inspectors’ words, 812 words
“IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 33921 Based on observation, a review of the Centers for Disease Control and Prevention (CDC) guidelines and recommendations, a review of facility Procedures, and staff interview, it was determined that the Infection Control Committee failed to ensure that one of one Registered Nurse, (RN AA), observed during discontinuation of hemodialysis (HD) treatment on one of one Patient, (P), (P#8), and initiation of HD treatment on one of one patient, (P#9), who both had Central Venous Catheters (CVCs), utilized appropriate infection control techniques to prevent cross contamination. This breach in infection control techniques could negatively affect the health and safety of P#8 and P#9 and other patients who had CVCs, as their primary dialysis access. The facility had 37 in-center hemodialysis patients. Findings were: During observation in the Patient Treatment Room on 8/28/24 between 9:50 a.m. and 11:40 a.m., the following was revealed: - RN AA was observed during discontinuation of HD treatment on P#8 at Station (S), (S8). After disconnecting the used bloodlines (the arterial and venous ends of the extracorporeal circuit that connect the patient’s catheter to the dialyzer), from the CVC, RN AA did not disinfect the CVC hubs (the end of the CVC that connects to the blood lines or caps) before flushing the CVC limbs (the catheter that extends from the patient’s body to the hub) with Normal Saline flushes and Heplock (anticoagulant locking solution). RN AA only disinfected the CVC hubs prior to re-capping the hubs with new end caps, (cap - refers to a device that screws on to and occludes the hub). - RN AA was observed during initiation of P#9’s hemodialysis treatment at S16. RN AA did not remove used gloves and did not perform hand hygiene after removing P#9’s old CVC exit site dressing. Instead, RN AA proceeded to clean/disinfect P#9’s CVC exit site wearing the same contaminated gloves. - RN AA stated on 8/28/24 at 11:25 a.m., that he didn’t realize that he failed to change gloves and to perform hand hygiene after removing P#9’s old dressing. RN AA also added that he thought the CVC hubs (during termination of HD treatment), were only disinfected once right before covering the hubs with new end caps. - According to the CDC, cross contaminating (going from dirty to clean tasks), could cause the spread of bacteria/infections. And even with glove use, hand hygiene is necessary after glove removal because hands can become contaminated through small defects in gloves and from the outer surface of gloves during glove removal ... - According to CDC, BEFORE ACCESSING catheter hubs, needleless connectors or injection ports, vigorously apply mechanical friction or “scrub the hub” for no less than five seconds with an antiseptic... - CDC’s disconnection steps: b. Disconnect the bloodline from the catheter and disinfect the hub with a new antiseptic pad. Scrub the sides (threads) and end of the hub thoroughly with friction, making sure to remove any residue (e.g., blood)... A review of facility Procedure: 1-04-02B titled, “Central Venous Catheter (CVC) with Clearguard HD Antimicrobial End Caps” with latest revision date of 10/23, stated: 4. Remove old dressing and discard. 7. Remove gloves and discard. Perform hand hygiene per procedure and re-glove. UPON COMPLETION OF DIALYSIS: 30. Clamp arterial catheter limb and blood line. Aseptically disconnect arterial blood line from arterial CVC limb. Attach a 10 mL (milliLiter, sic) syringe filled with normal saline to arterial catheter limb... 31. ... Aseptically disconnect venous blood line and connect 10 mL syringe with normal saline to the venous catheter limb... 32. If a CVC locking solution is prescribed, remove normal saline syringes and connect syringe appropriate for catheter lumen volume with prescribed locking solution to each catheter limb one at a time... 33. Remove syringes and disinfect the CVC hubs with a new alcohol prep pad for each CVC hub... The facility’s Procedure at completion of dialysis for patients with CVC, did not show “scrub the hub” after disconnection of used blood lines and CVC limbs and/or before accessing catheter hubs.”
-
Pe - Building - Constructed/Maintained To Ensure Safety
The inspectors’ words, 191 words
“PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 33921 Based on observation and staff interview, it was determined that the facility failed to ensure that the building in which dialysis services were provided, was maintained free from damage and defects to ensure the safety of the patients and staff. This failure to maintain the integrity of all surfaces could hinder effective cleaning and disinfection of the surfaces, thus providing a potential for microbial growth. This deficient practice was observed in one of one Dialysate Preparation Room. Findings were: - The pipe connector in the Granuflo Acid Mixer was covered with dust and a rust-colored substance. - The wooden door frame, of the back entrance and exit door, was partly coming off from the wall, and was not secured. - The drain area next to the Granuflo Acid Mixer was covered with whitish sediment. The Biomed Technician acknowledged these observations on 8/27/24 at 2:50 p.m. and stated that these will be addressed.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Aug 28, 2024 | Standard inspection | 3 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jul 14, 1977.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
- Doesn’t offer a shift starting at 5 p.m. or later.
- 24 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 3 dialysis facilities CMS lists in Glynn County, 3 have a star rating from CMS: 2 rated 3 of 5, 1 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Davita Brunswick South Dialysis | 3 |
| Fresenius Kidney Care Glynn County | 2 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.