Davita Preserve Point Dialysis

A dialysis facility in Palm Coast, Florida 32164

57 Town Court Rd, Ste 118, Palm Coast, Florida 32164. (386) 309-2885.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited Mar 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Mar 13, 2024: a standard inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited Mar 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Mar 13, 2024: standard inspection6 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 884 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 35966 Based on observation, staff interview and policy review, the facility failed to follow infection control practices during Central Venous Catheter (CVC) Exit Site Care and Initiation of Dialysis with Central Venous Catheter for two of two observations on 3/11/24 (Patient #1, Patient #5); failed to follow infection control practices when using computer keyboard between patient stations for one observation; failed to follow infection control practices when cleaning the hemodialysis machine for one observation; and failed to follow infection control practices when preparing the hemodialysis machine for one observation. The findings include: 1. During an observation of CVC Exit Site Care for Patient #5 at Station 16 on 3/11/24 at 10:00 AM, Staff C removed the old dressing, removed her gloves, and discarded the dressing and gloves into a waste bin. Staff C then put on clean gloves before performing hand hygiene. Staff C cleaned the area around the CVC exit site with antiseptic, applied a sterile dressing, and removed her gloves. Staff C then began the Initiation of Dialysis with a CVC by donning new gloves without performing hand hygiene, and began disinfecting the CVC hubs. During the interview with Staff C on 3/11/24 at 10:25 AM, it was confirmed that she had forgotten to perform hand hygiene before putting on new gloves. 2. During an observation of CVC Exit Site Care for Patient #1 at Station 5 on 3/11/24 at 10:35 AM, Staff D removed the old dressing and discarded the dressing into a waste bin. Staff D then cleaned the area around the CVC exit site with antiseptic and applied a sterile dressing. Staff D began the Initiation of Dialysis with a CVC by disinfecting the CVC hubs, flushed the ports with saline, and initiated treatment without changing gloves or performing hand hygiene. Staff D then proceeded to use the computer keyboard located between stations which accesses the patient’s electronic medical record while wearing the gloves used during the CVC Exit Site Care and Initiation of Dialysis. During the interview with Staff D on 3/11/24 at 10:40 AM, it was confirmed that the keyboard is a clean area and he did not take his gloves off. He stated he did not change his gloves while taking care of Patient #1 because his hands “get too sweaty” and “It’s too hard to change the gloves as often as I should.” 3. During an observation of Cleaning and Disinfection of the Dialysis Machine on 3/11/24 at 10:16 AM at Station 3, Staff D was cleaning the hemodialysis machine when Patient #10 needed assistance with his pants. Staff D stopped cleaning the machine and assisted the patient with the drawstring on his pants. Staff D continued to clean the dialysis machine without changing gloves and performing hand hygiene. 4. During an observation of Preparation of the Hemodialysis Machine at Station 4 on 3/13/24 at 10:45 AM, Staff D was asked by Staff A for supply assistance at Station 3. Staff D paused the preparation of the hemodialysis machine, walked to the supply area and opened a drawer for gauze, handed the gauze to Staff A, and continued to prepare the machine without removing gloves and performing hand hygiene. The facility policy titled “Infection Control for Dialysis Facilities” revised on April 2023 states “All teammates, Physicians and Non-Physician will perform hand hygiene upon entering and exiting the patient treatment area, prior to gloving and immediately after removal of gloves, after contamination with blood or other infectious material, after patient and dialysis delivery system contact, after interacting with wall boxes, between patients even if contact is causal, before touching clean areas such as supplies, supply cart and chairside keyboard/mouse.” The policy continues to state “Gloves should be changed when soiled with blood, dialysate or other body fluids, when going from “dirty” area or task to “clean” area or task, when removing from a contaminated body site to a clean body site of the same patient and, after touching one patient or their dialysis delivery system and before arriving to care for another patient or touch another patient’s dialysis delivery system.” The facility policy/procedure titled “Central Venous Catheter (CVC) with Clearguard HD antimicrobial end caps procedure” states, “3. Place patient in comfortable supine position, as tolerated. Verify patient’s clothing is secured away from the exit site/work area. Place the second moisture proof barrier under catheter limbs. Instruct patient to turn head to opposite side of CVC exit site. 4. Remove old dressing and discard. 5. Observe site for signs and symptoms of infection such as redness, drainage, swelling or tenderness. If present, report to RN/physician. 6. Verify that both arterial and venous catheter limbs are clamped. 7. Remove gloves and discard. Perform hand hygiene per procedure and re-glove.” An interview with the Facility Administrator on 3/11/24 at 1:00 PM confirmed that hand hygiene is to be performed after every glove change. An interview with the Facility Administrator and Manager of Clinical Services on 3/13/24 at 11:00 AM confirmed glove change and hand hygiene is to be performed when moving between clean and dirty areas. .”

    Rule V0113. Standard-level.

  • Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts

    The inspectors’ words, 630 words

    “IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 35966 Based on observations, interviews and review of the facility’s parenteral medication preparation policies and procedures, the facility failed to label nine Heparin syringes with time of preparation (time the medication was drawn into syringe), label the 9 syringes with the nurse’s initials who prepared the medication, and failed to store the prepared syringes at the nurse’s station. Six syringes were left unattended on a counter adjacent to the nurse’s station. The counter is in a highly traveled area and can be accessed by patients and visitors. One heparin syringe was observed on the chairside table at Station 5 with no patient seated to receive dialysis treatment. One heparin syringe was observed on the counter across from Station 5. One heparin syringe was observed on the chairside table at Station 16 with no patient seated to received dialysis treatment. The findings include: On 3/11/24 at approximately 9:40 AM, an observation was made of six syringes labeled as Heparin on the open counter adjacent to the nurse’s station. The syringes were observed to have a pre-printed label that included the medication name, dosage and date. The labels had two spaces to indicate the time the medication was prepared and a space for the nurse’s initials who prepared the medication. The two spaces were left blank. The syringes were out on the open counter, accessible to patients and visitors. On 3/11/24 at approximately 9:45 AM, an observation was made of 1 syringe labeled as Heparin sitting on the chairside table of Station 5. The pre-printed label did not indicate who prepared the medication or when. The patient had not arrived for dialysis treatment at this time. Across from Station 5, another syringe labeled as Heparin sat atop a copy of the patient schedule for the day. The syringe was not labeled with who prepared the medication or when. On 3/11/24 at approximately 9:50 AM, an observation was made of 1 syringe labeled as Heparin sitting on the chairside table of Station 16. The label did not indicate who prepared the medication or when. The patient had not arrived for dialysis treatment at this time. The facility’s policy: 1-06-01A, titled, Preparation and Administration of Parenteral Medications (Non-Epo, Non-Parsabiv) with all Dialyzer Types, last revised October 2023 states, “Label the syringe with the patient’s name, name of the prescribed medication, dose, date, time, and initials of licensed teammate preparing the dose. Preprinted labels may be used if available. Distribute the medication to the patient station in an aseptic manner.” During an interview with the Facility Administrator and the Manager of Clinical Services on 3/11/24 at 11:00 AM, it was confirmed the medications must be initialed and include a time of preparation. It was also stated that medications must not be brought to the treatment station prior to the patient arriving for treatment and that medications are to be kept at the nurse’s station when they are not being administered. .”

    Rule V0117. Standard-level.

  • Ic - Supply Cart Distant/No Supplies In Pockets

    The inspectors’ words, 205 words

    “IC-SUPPLY CART DISTANT/NO SUPPLIES IN POCKETS CFR(s): 494.30(a)(1)(i) If a common supply cart is used to store clean supplies in the patient treatment area, this cart should remain in a designated area at a sufficient distance from patient stations to avoid contamination with blood. Such carts should not be moved between stations to distribute supplies. Do not carry medication vials, syringes, alcohol swabs or supplies in pockets. This Standard is not met as evidenced by: 35966 Based on observation and staff interview, the facility failed to keep a common supply cart with medical supplies away from patient treatment stations. The findings include: On 3/11/24 at 10:00 AM, Staff #A was observed rolling a medical supply cart to treatment station #16 to provide care to a patient. The supply cart was a black square plastic cart with wheels that had a box of gloves, straws, cups, water, and stethoscope. An interview with the Facility Administrator at 11:00 am on 3/11/24 confirmed that a common supply cart should not be rolled to patient stations. The facility policy titled “Preparation and Administration of Parenteral Medicals (Non-epo, Non-Parsabiv) with all dialyzer types” revised October 2023 states, “Rolling medication carts must not be used to dispense or administer medications”. .”

    Rule V0119. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 711 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 35966 Based on observation, staff interview, and policy review, the facility failed to ensure that patients had vacated the dialysis station before initiating disinfection of the dialysis machine; the facility failed to disinfect the prime waste containers at two (#2, #4) stations; failed to change sanitation cloths between the cleaning of the hemodialysis machine and the treatment chair for two (#2, #4) stations; and failed to disinfect the treatment chair surfaces, to include the open-sides and inclined-surface of the chairs for two (#2, #4) stations. The findings include: 1. During an observation conducted on 3/11/24 beginning at approximately 9:20 AM, Patient Care Technician (PCT) B, disinfected the hemodialysis machine at station 11 and prepared it for the next patient. This was completed while a patient remained in the dialysis chair awaiting vascular access hemostasis (stopping the flow of blood). PCT B moved on to disinfect the dialysis machine at station 13 and prepared it for the next patient while a patient remained seated in the dialysis chair awaiting hemostasis. During an interview on 3/11/24 at 11:00 AM, the Facility Administrator confirmed that patients need to vacate the dialysis station prior to initiating disinfection of the station. The facility policy titled “INFECTION CONTROL FOR DIALYSIS FACILITIES” revised April 2023 stated, “Dialysis station must be completely vacated by the previous patient before teammates can begin to bring disinfection supplies to the station, clean or disinfect the station and set up for the next patient.” The Centers for Medicare & Medicaid Services (CMS) states in memo Survey & Certification 17-32-ESRD (dated 6/2/17 and accessed 3/11/24), “The Centers for Disease Control and Prevention (CDC) has recommended that a dialysis station, in order to prevent cross contamination, be completely vacated by the previous patient before the ESRD staff may begin cleaning and disinfection of the station and set up for the next patient.” 2. (a) During observation of cleaning and disinfection of Station #2 on 3/13/24 at 10:25 AM, PCT #D began to clean the hemodialysis machine with a cloth soaked in 1:10 bleach. PCT #D did not remove or sanitize the prime waste container that was attached to the side of the hemodialysis machine. PCT #D then used the same bleach cloth to wipe down the treatment chair. PCT #D failed to open the treatment chair arms and tilt-back the reclining feature of the chair to disinfect all surfaces of the chair. (b) During observation of cleaning and disinfection of Station #4 on 3/13/24 at 10:30 AM, PCT #D began to clean the hemodialysis machine with a cloth soaked in 1:10 bleach. PCT #D did not remove or sanitize the prime waste container that was attached to the side of the hemodialysis machine. PCT #D then used the same bleach cloth to wipe down the treatment chair. PCT #D failed to open the treatment chair arms and tilt-back the reclining feature of the chair to disinfect all surfaces of the chair. The facility policy titled “Infection Control for Dialysis Facilities” revised on April 2023 states, “At the end of each treatment, the dialysis station will be cleaned and disinfected. Surfaces to disinfect include but are not necessarily limited to: all surfaces in contact with the patient or their belongings (e.g., dialysis chair, tray tables, blood pressure cuffs) and frequently contacted by healthcare personnel (e.g., control panel; top and sides of dialysis machine; touchscreens; countertops). Priming containers are to be emptied prior to disinfection. Drain line and water supply line should not be placed with the ends in prime containers or in a position where they can drip into or contaminate the prime bucket.” An interview with the Manager of Clinical Services on 3/13/24 at 11:20 AM confirmed the prime waste container is to be removed and sanitized, the staff is to use a separate cloth on the chair and the hemodialysis machine, and the chair is to be reclined and cleaned down the sides of the seat cushion. .”

    Rule V0122. Standard-level.

  • Pe - Safe, Functional, Comfortable Environment

    The inspectors’ words, 186 words

    “PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 35966 Based on observation and staff interview, the facility failed to maintain a safe environment for its patients by not ensuring the staff entrance door from the parking lot was closed and secured. The findings include: At 8:55 am on 3/11/24, an external door labeled “118” was observed with the latch unlocked. The surveyor pulled the door open and observed a hallway that lead to offices, a breakroom, supplies, and the patient treatment floor. The surveyor closed the door and entered the facility from the patient entrance. An interview with the Facility Administrator at 9:05 am on 3/11/24 confirmed the door was stuck open. The Administrator stated they had previous issues with the door that should have been repaired. The facility policy titled “Physical Environment” revised April 2018 states, “Access to patient treatment areas, water treatment system, supply storage and dialysis equipment is restricted to authorized personnel only.” .”

    Rule V0401. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 456 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 35966 Based on record review and staff interview, the facility failed to follow physician orders for prescribed Blood Flow Rate (BFR) for one of four (Patient #1) sampled Hemodialysis Patients; and the facility failed to follow physician orders for prescribed Dialysate Flow Rate (DFR) for two of four (Patients #1 & #4) sampled Hemodialysis Patients. The findings include: 1. (a). Review of the hemodialysis treatment sheet record for Patient #1 dated 2/21/24 showed the BFR was changed from 400 to 305 at 12:32 PM and continued until end of treatment at 1:25 PM. The physician order for 2/21/24 showed a BFR of 400. Interview with the Manager of Clinical Services on 3/12/24 at 1:00 PM confirmed the BFR was lowered and there was no documentation indicating why it was changed. The treatment sheet record dated 3/4/24 showed the BFR was changed from 400 to 330 at 12:01 PM and continued until end of treatment at 12:56 PM. The physician order for 3/4/24 showed a BFR of 400. An interview with the Manager of Clinical Services on 3/12/24 at 1:00 PM confirmed the BFR was lowered and there was no documentation indicating why it was changed. (b). Review of the hemodialysis treatment sheet record for Patient #1 dated 3/1/24 showed a DFR of 500 at 9:41 AM and continued until end of treatment at 12:42 PM. The physician order for 3/1/24 showed a DFR of 600. An interview with the Manager of Clinical Services on 3/12/24 at 1:00 pm confirmed the DFR was set incorrectly at the beginning of treatment and there was no documentation indicating why physician orders were not followed. 2. (a). Record review of the hemodialysis treatment sheet for Patient #4 showed on 2/19/24 the patient received a DFR of 500 from the beginning of treatment at 12:00 PM until treatment ended at 2:52 PM. The hemodialysis treatment sheet dated 2/26/24 showed the patient received a DFR of 500 from the beginning of treatment at 2:17 PM until treatment ended at 5:13 PM. The hemodialysis treatment sheet dated 3/1/24 showed the patient received a DFR of 500 from the beginning of treatment at 12:02 PM until treatment ended at 2:56 PM. The physician orders for those dates showed a DFR of 600. An interview with the Manager of Clinical Services on 3/12/24 at 1:00 pm confirmed the DFR was set incorrectly for the duration of treatment with no documentation as to why the orders were not followed. .”

    Rule V0543. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Mar 13, 2024Standard inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Dec 15, 2020.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 15 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 4 dialysis facilities CMS lists in Flagler County, 4 have a star rating from CMS: 2 rated 3 of 5, 1 rated 2 of 5, 1 rated 1 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.