Fresenius Kidney Care-East Fort Walton Beach
A dialysis facility in Fort Walton Beach, Florida 32547
315 Green Acres Road, Fort Walton Beach, Florida 32547. (850) 314-0035.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 6 deficiencies cited in the last three years
- 16 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jul 23, 2025: a standard inspection.
6 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
6 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jul 23, 2025: standard inspection6 deficiencies
-
Ic - Sanitary Environment
The inspectors’ words, 221 words
“IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 29722 Based on observations, the facility faled to enssure the items considered clean, to incude patient wheelchairs, were stored in an area to prevent cross contamination. The findings include: On 07/22/2025 at approximately 9:16 AM, Staff C, a Patient Care Technician (PCT) was observed while discontinuing and removing fistula needles from the Patient at Station #14. The PCT was observed to walk the needles around the patient to the sharps container, passing over the clean oxygen concentrator positioned next to the Sharps container, to which he disposed of the needles. On 07/22/2025 at 9:41 AM observed between Stations #13 and #14, was a “clean” air concentrate positioned and touching the SharpSmart biomedical waste container which contained discarded arterial and venous catheter needles/lines. (Photo documenttion obtained) On 07/22/2025 at 11:35 AM observed was a patient’s walker parked directly in front of a Sharpsmart biomedial waste bin and alongside an open lid red biohazardous waste box. (Photo documenttion obtained) On 07/22/2025 at 11:56 AM observed was a patient’s walker parked directly beside an opened-lid red biohazardous waster container. (Photo documentation obtained)”
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 657 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 29722 Based on observations, interviews and review of the facility’s policy and procedure, the facility failed to ensure the use of proper hand hygiene after removing gloves on numerous observations made. (Staff C) The findings include: On 07/21/2025 at approximately 11:40 AM, the process of cleaning and disinfection of the dialysis Station #16 was observed performed by Staff C, a Patient Care Technician.” While wearing a pair of gloves, Staff C was observed to remove and discard the bloodlines. He proceeded to the bleach wipe container, located in a central area. There were no wipes in the bleach container. While his hands remained gloved, he opened a drawer and retrieved a new package of wipes and placed them in the bleach solution. He removed his gloves and donned a new pair. He continued to wipe down the machine, failed to empty the prime receptable he unhooked the standard bath lines and connected to the machine. Without changing gloves Staff C went over to Station #14 and moved the dialysis machine. He then removed his gloves. Observed at 12:16 PM, the chair from Station #16 has still yet to be cleaned. Without wearing gloves, he removes the prime receptacle bin from Station #16 and empties into the “clean” sink. On 07/22/2025 at 9:00 AM, two patients who were seated next to each other at Stations #13 and #14 were interviewed. Both were asked if they had any concerns with the facility’s infection control practices. Both stated they did have concerns, in particular, with new staff not washing their hands after changing gloves. Neither patient voiced any hesitancy in speaking out with their concerns but indicated staff don’t like it and felt like staff needed to listen to them more, “we know our own bodies.” On 07/22/2025 at approximately 9:27 AM, Staff C, a Patient Care Technician (PCT) was observed to don on a pair of gloves and respond to a machine alarm at Station #4. Staff C then removed his gloves and failed to wash or sanitize his hands. He proceeded to walk around the treatment floor. Dons on a new pair of gloves and finishes machine set up at Station #11. This same technician then returns to Station #4 wearing gloves, removes his gloves. Does not sanitize his hand. Picks up a box of gloves and bring them to a central area. He dons on a new pair of gloves and proceeds to Station #3. Staff C then removes his gloves and sanitizes his hands at Station #2. While at Station #2, the PCT, while wearing gloves, visualizes the patient’s access by touching the patient. He removes the gloves and fails to sanitize his hands. Staff C dons on a new pair of gloves and goes to Station #1. He removes his gloves, fails to sanitize his hands then goes to Station #4. A review of the facility’s policy and procedure entitled “Hand Hygiene” published 11/06/2023, reference number 47664, indicates, “ All staff, patients, patient care givers, including physician and non-physician practitioners, social workers, dietitians, and any other indirect patient care staff must follow the same requirements for hand hygiene. The policy indicates that “Decontamination using alcohol-based hand rub or by washing hands with antimicrobial soap and water” - “Before and after direct contact with patients; Entering and leaving the treatment area; Before performing any invasive procedure such as vascular access cannulation or administration of parenteral medicals; Immediately after removing gloves; After contact wit body fluids or excretions, mucous membranes, non-intact skin, and wound dressings if hands are not visibly soiled; after contact with inanimate objects near the patient; When moving from a contaminated body site to a clean body site of the same patient”
-
Ic - Aseptic Techniques For Iv Meds
The inspectors’ words, 267 words
“IC-ASEPTIC TECHNIQUES FOR IV MEDS CFR(s): 494.30(b)(2) [The facility must-] (2) Ensure that clinical staff demonstrate compliance with current aseptic techniques when dispensing and administering intravenous medications from vials and ampules; and This Standard is not met as evidenced by: 29722 Based on observation, interview and reviw of the facility’s policy and procedure, the facility failed to ensure staff demonstrated compliance with current aseptic techniques when accessing medicals from vials. The findings include: On 07/22/2025 at 10:44 AM, the LPN (Licensed Practical Nurse), Staff K, was observed to open a new vial of Venofer (an iron medication for treating anemia). The LPN failed to disinfect the rubber septum before withdrawing the medication from the vial. On 07/22/2025 at 11:05 AM an interview was conducted with the Charge Nurse, Staff F. She stated that newly opened vials should be disinfected after opening and before accessing medication. On 07/22/2025 at 11:10 AM an interview was conducted with the LPN, Staff K. She stated she was not aware that newly opened vials of mediation needed to be disinfected before accessing - stating, “I just learned something new.” A review of the facility’s policy entitled “5008X Medication Preparation and Administration”, published on 07/07/2025, reference number 64475, indicates on page 6 of 12 under the heading of Infection Control - “Cleanse the diaphragm of a vial with alcohol prior to accessing the vial. If the vial is a multidose vial, cleanse the diaphragm with a new alcohol pad each time the vial is accessed with a needle using friction and 70% alcohol. Allow to dry before inserting a device into the vial.””
-
Pe - Hemodialysis Patients In View During Treatments
The inspectors’ words, 234 words
“PE-HD PTS IN VIEW DURING TREATMENTS CFR(s): 494.60(c)(4) Patients must be in view of staff during hemodialysis treatment to ensure patient safety, (video surveillance will not meet this requirement). This Standard is not met as evidenced by: 29722 Based on observations and staff interviews, the facility failed to ensure the patient’s vascular access remained visible and uncovered during the course of treatment for 1 of 16 patients observed at Station 9. The findings include: On 07/22/2025 at 11:21 AM, the patient at Station #9 was observed to have a blanket pulled all the way up to the chin. The patient’s vascular access was not visible. On 07/22/2025 at 11:37 AM, the patient at Station #9 remained with the blanket pulled up to the chin. The patient’s vascular access was not visible. On 07/22/2025 at 11:48 AM, the patient at Station #9 remained with the blanket pulled up to the chin. The patient’s vascular access was not visible. On 07/22/2025 at 11:58 AM, the patient at Station #9 remained with the blanket pulled up to the chin. The patient’s vascular access was not visible. On 07/22/2025 at 11:58 AM an intrview was cndcuted with Staff F, the Charge Nurse, she stated the vascular access sites should remain uncovered. The patient at Station #9 was identified. The Charge Nurse informed the Patient Care Technician (PCT), who then lowered the patient’s blanket revealing the vascular access site.”
-
Assess Anemia
The inspectors’ words, 437 words
“PA-ASSESS ANEMIA CFR(s): 494.80(a)(4) The patient’s comprehensive assessment must include, but is not limited to, the following: (4) Evaluation of factors associated with anemia, such as hematocrit, hemoglobin, iron stores, and potential treatment plans for anemia, including administration of erythropoiesis-stimulating agent(s). This Standard is not met as evidenced by: 29722 Based on observations, interviews, review of the facility’s policy and procedure as well as online review of medication packaging information, the facility failed to ensure the proper administration of Venofer, an iron sucrose medication used to treat anemia, for 1 of 1 patients observed for medication administration ( Station #2). The findings include: On 07/22/2025 at 10:44 AM, the Licensed Practical Nurse (LPN)), was observed to draw up 100mg of Venofer in a luer-lock syringe. She proceeded over to Station #2. The patient at Station #2 had 10-minute left of trreatment. The LPN, disinfected the IV line port nearest the normal saline bag and in one swift motion injected the entire contents, Venofer 100mg, (milligrams) into the IV (intravenous) line. The LPN was asked when Venofer should be administered, she stated towards the end of treatment because it can cause clotting of the line. On 7/22/2025 at approximately 11:10 AM an interview was conducted with a visiting Facility Administrator, who was present during the survey, she was not aware of any particular indications as to when Venofer should be administered. On 07/22/2025 at approximately 11:20 AM a different visiting FA was asked about the administration of Venofer. She stated the medication should be administered over 3 - 5 minutes. She was not aware, at what point in the patient’s treatment the Venofer should be administered. A review of the facility’s policy entitled “Special Considerations: Venofer,” published 07/01/2024 reference number 47534, indicates “Venofer may be administered undiluted as a slow intravenous injection over 2 to 5 minutes...” Venofer should be administered ealry during the dialysis session generally within the first hour.” A review of the medication package insert, located online at Venofer.com, under “Full Prescribing Information,” indicates “DOSAGE AND ADMINISTRATION: 2.1 Mode of Administration, Administer Venofer only intravenously by slow injection or by infusion. The dosage of Venofer is expressed in mg (milligram) of elemental iron. Each mL contains 20 mg of elemental iron. 2.2 Adult Patients with Hemodialysis Dependent-Chronic Kidney Disease (HDD-CKD)Administer Venofer 100 mg undiluted as a slow intravenous injection over 2 to 5 minutes, or as an infusion of 100 mg diluted in a maximum of 100 mL of 0.9% NaCl over a period of at least 15 minutes, per consecutive hemodialysis session. Administer Venofer early during the dialysis session (generally within the first hour).””
-
Achieve Adequate Clearance
The inspectors’ words, 432 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 29722 Based on observations, interviews, patient treatment records reviews and review of the facility’s policy and procedure, the facility failed to ensure that the patient dialysis prescription was followed for 2 of 4 prescriptions verifications performed. (Station #9) The findings include: On 07/21/2025 at 10:48 AM, with the assistance of Staff F, the Charge Nurse, the dialysis prescription for the patient at Station #9 was verified. The patient was initiated for treatment at 10:18AM. A check of the patient’s currently running Blood Flow Rate (BFR) revealed a rate of 400 mL/min (mililiter/minutes). The patient’s physician prescribed BFR was 450 mL/min. A review of the treatment record failed to indicate why the prescriibed blood flow rate was not followed. The Charge Nurse stated that there should be a note. Staff F then attempted to increase the patient’s BFR, but due to high arterial pressures, the rate had to be lowered. A notation was then made into the record. On 07/21/2025 at 2:00 PM, with the assistance of Staff B, a Registered Nurse, the dialysis prescription for the patient at Station #7 was verified. The patient’s dialyzer was checked, the patient was currently dialyzing on a 180NRe Optiflux. A review of the physician prescribed prescription indicated a 160NRe Optiflux. The patient was dialyzing on the wrong dialyzer. On 07/21/2025 at approximately 2:40 PM an interview was conducted with the Charge Nurse, Staff F, she was asked about prescription verification process. She stated the prescription is verified by the person who sets up the machine and another check is done when the patient gets on the machine. She was asked to see if there had been a recheck of the prescription for the patient at Station #7. She was able to pull up the patients treatment record information and could see that Staff B, an RN, had set the machine up and the machine recheck had been commplted by Staff K, a Patient Care Technician. The Charge Nurse was informed that the patient had the wrong dialyzer. A review of the facility’s policy entitled “Pre-Treatment Safety Checks Procedure,” published on 02/06/2023 with a reference number 47798, indicates under the heading “Pre-Dialysis Safety Checks,” to “Verify the following elements by two direct patient care staff members prior to treatment initiation: ... Prescribed dialyzer””
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jul 23, 2025 | Standard inspection | 6 deficiencies cited |
| Mar 27, 2024 | Complaint inspection | No deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Apr 18, 2018.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 16 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 5 dialysis facilities CMS lists in Okaloosa County, 5 have a star rating from CMS: 1 rated 3 of 5, 4 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Rcg - Ft Walton Beach | 2 |
| Davita Emerald Coast Dialysis | 2 |
| Nephrology Center of Crestview | 2 |
| Fmc - Niceville | 2 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.