Hearth Record

Davita Orlando Airport Dialysis

A dialysis facility in Orlando, Florida 32822

5778 S Semoran Blvd, Suite A, Orlando, Florida 32822. (407) 282-3835.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited May 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Dec 16, 2024: a complaint inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited May 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

May 9, 2024: standard inspection6 deficiencies
  • Dialysis Emergency Equipment

    The inspectors’ words, 776 words

    “Dialysis Emergency Equipment CFR(s): §494.62(b)(9) Condition for Coverage: [(b) Policies and procedures. The dialysis facility must develop and implement emergency preparedness policies and procedures, based on the emergency plan set forth in paragraph (a) of this section, risk assessment at paragraph (a)(1) of this section, and the communication plan at paragraph (c) of this section. The policies and procedures must be reviewed and updated at least every 2 years. At a minimum, the policies and procedures must address the following:] (9) A process by which the staff can confirm that emergency equipment, including, but not limited to, oxygen, airways, suction, defibrillator or automated external defibrillator, artificial resuscitator, and emergency drugs, are on the premises at all times and immediately available. This Standard is not met as evidenced by: 39943 Based on observation, interview, and record review the dialysis center failed to timely implement emergency equipment check procedures for their emergency crash cart for 1 of 1 crash cart. Findings: On 5/08/24 at 2:10 PM, observation revealed one emergency [crash] cart on the dialysis treatment floor. The crash cart contained emergency mediations for allergic reactions, and other emergencies. The crash cart had emergency equipment on top of it. There was a suction machine, an automated external defibrillator (AED), airways, and an artificial resuscitator (ambu bag). Emergency oxygen tanks were noted to the right side of the crash cart. On 5/08/24 at 3:00 PM, a review of the Emergency Crash Cart check list with the Facility Administrator (FA) confirmed the crash cart did not have a par list of medications and equipment check list and the FA could not state when the emergency cart contents were last checked. The FA stated the Manager of Clinical Services (MCS) completed a facility wide safety check and the emergency cart was among the concerns found during the safety check. She stated the facility had a QAPI in place and stated the facility had 30 days to bring the emergency cart into compliance. The facility’s ‘Emergency Equipment Checklist’ was then reviewed with the FA. It revealed that the emergency equipment which included the AED was last checked on 4/29/24, 9 days earlier. The FA acknowledged that the emergency equipment was supposed to be checked on a weekly basis. She said that the AED should be checked every day for a green light and check mark and that the Emergency Medication Breakaway Lock was intact. The “Daily Zoll AED and Emergency Medication Lock Log,” revealed the log only had documentation of being checked five days out of eight. The FA acknowledged the items were not checked daily. She stated it was the nurse’s responsibility to check the emergency cart. On 5/08/24 at 5:40 PM the FA stated the facility had a QAPI for the Emergency Crash Cart and they have been doing audits on the concerns found during the safety check. She stated the facility had thirty days to fix all the concerns. Review of the list of audits being completed included, daily AED checked, daily water log complete, glucometer log complete, and Patient head and access uncovered. She acknowledged that the Emergency Cart should not take thirty days and should have been addressed sooner. On 5/09/24 at 9:45 AM, the MCS stated the facility is not required by policy to have a list of what is in the crash cart. She did acknowledge that the facility takes the Emergency Crash Cart with them if and when they had to evacuate and she agreed there should be a list of contents for the cart. On 5/09/24 at 10:15 AM, the MCS checked the Emergency Cart and found expired supplies to include six-1 liter bags of Normal Saline. The MCS stated she expected the cart to be checked as required and should have no expired supplies. Review of the dialysis center’s policy and procedure, ‘Emergency Equipment Checks”, Origination date September 2007 and last revised, April 2024, included the following: “Purpose: To verify that emergency equipment is maintained in a ready-to-use condition. ... The following equipment checks will be performed by a licensed nurse teammate to verify the designated equipment is available and functional. Daily: Check Status Indicator lights for [AED] ... Check break away lock is intact. ... Weekly: [Check] Oxygen supply is adequate ... Airways are available ...Suction is operational ... AED is operation and pads are compatible with AED device ... Ambu bag is operational ... Emergency cart (crash cart is clean, operation and supplies/medications have not expired ... . A list of all dated supplies will be posted with the expiration dates, on the cart and is to be checked weekly by licensed nurse teammate assigned to check the emergency cart.”

    Rule E0028. Standard-level.

  • Ic - Sanitary Environment

    The inspectors’ words, 472 words

    “IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 13640 Based on observation, interview and a review of facility documentation, the facility failed to ensure the maintenance of a sanitary environment concerning residue on or beneath PVC pipe elbows through which water drains out from the hemodialysis machines, water drips from a pipe elbow, as well as stained surfaces on water boxes and hemodialysis machines in 12 of 24 hemodialysis stations (2, 3, 6, 9, 12, 13, 15, 16, 17, 20, 22 and 23) and 1 of 26 hemodialysis machines . ( #14) Findings: During an observation of the treatment floor from approximately 9:30 AM to 9/55 AM the following was found. White colored residue was observed on the floor beneath the cabinets that housed water distribution and drainage piping. They were isolated to areas directly beneath respective PVC pipe elbows through which drainage water from the hemodialysis machines was directed for disposal. These elbows protruded from the bottom of the cabinet structures. This involved the following stations: 2, 6, 12, 15, 16, 17, 20, 22 and 23. A white, caked residue was observed on the PVC pipe elbows through which drainage water from the hemodialysis machines was directed for disposal. This involved station #2. Brown / black staining was observed on the PVC pipe elbows through which drainage water from the hemodialysis machines was directed for disposal. This involved the following stations: 3 and 9. Brown staining was observed on the lower, horizontal aspect of the framing of the water box at station 6. It was through this part of the frame that a vertical PVC pipe was positioned for the drainage water from the hemodialysis machines and was directed to a PVC pipe elbow for disposal.. Brown staining was observed on the horizontal platform on the front side of the hemodialysis machine, near floor level, on machine #14. This platform is commonly used to house jugs. A slow water drip was observed from PVC pipe elbows through which drainage water from the hemodialysis machines was directed for disposal, for station #13. A review of facility policy Infection Control for Dialysis Facilities revealed the following: “The Wall box, Drain and Water supply lines are considered part of the dialysis delivery system. . . . Teammates will monitor and address wall box residue / build up and patency issues.” During an interview of the Biomedical Manager on 5/9/24 at approximately 10:20 AM, he stated that the staining was residue. He confirmed that the affected areas as described above had not been cleaned appropriately. During an interview of the Administrator on 5/9/23 at approximately 12:02 PM, she confirmed the preceding.”

    Rule V0111. Standard-level.

  • Softeners - Testing Hardness/Log

    The inspectors’ words, 221 words

    “SOFTENERS: TESTING HARDNESS/LOG CFR(s): 494.40(a) 6.2.4 Softeners: Testing hardness/log Users should ensure that test accuracy and sensitivity are sufficient to satisfy the total hardness monitoring requirements of the reverse osmosis machine manufacturer. Total hardness of the water exiting the water softener should be measured at the end of each treatment day. Water hardness test results should be recorded in a water softener log. This Standard is not met as evidenced by: 13640 Based on observation, interview and a review of facility documentation, the facility failed to ensure that staff was competent in the process of testing total hardness of water. Findings: During an observation of testing for water hardness on 5/8/24 at approximately 11:10 AM by PCT- A, she was observed to read the strip for comparison to a color scale immediately upon removing the strip from the water sample. A review of the instructions for use of the testing strips revealed the following: (1) Dip test strip for 5 seconds into test solution; (2) Gently shake off excess liquid; (3) After 15 seconds, compare test pad color with color scale on container. Since the strip was evelauated immediately, the manufacturer’s instructions had not been followed. During an interview of PCT-A at the above stated time, she confirmed that she should have waited 15 seconds to compare the test pad color.”

    Rule V0191. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 229 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 39943 Based on observation and interview the facility failed to ensure that equipment in the form of Vacutainer blood collection tubes were maintained with respect to expiration dates to provide a safe treatment environment. Findings: During an observation of the lab area of the facility on 5/8/24 at approximately 2:45 PM the following blood collection tubes were found to be expired: 4 containers of 100 purple top tubes expired 12/31/23 3 containers containing 100 purple top tubes and 1 container with 99 tubes expired 1/31/24 1 container containing 100 purple top tubes expired 3/31/24 3 marble top tubes expired 3/2024 3 gray top tubes expired 3/2024 8 Microorganism Collection and Transport collection kits expired 0 n 9/13/24 and 4 expired on 12/07/23 2 blue top saline collection tubes expired on 1/24. On 5/08/24 at 2:56 PM the Facility Administrator (FA) stated the facility does not have an inventory tech. She stated that whoever receives the delivery will look at the current supply and remove anything that is expired. The FA reviewed the expired tubes found and acknowledged the expiration dates.”

    Rule V0403. Standard-level.

  • Rights Posted With State/Nw Contact #S And Addresses

    The inspectors’ words, 209 words

    “PR-RIGHTS POSTED,STATE/NW ONTACT INFO CFR(s): 494.70(c) The dialysis facility must prominently display a copy of the patient’s rights in the facility, including the current State agency and ESRD network mailing addresses and telephone complaint numbers, where it can be easily seen and read by patients. This Standard is not met as evidenced by: 39943 Based on observation and interview, the dialysis center failed to display the complaint contact information of the State Agency and for patient access and use. Findings: On 5/08/24 at 9:15 AM, observation of the dialysis center’s front lobby area revealed the mailing address and telephone complaint hotline number to the State Agency was not posted. At 2:30 PM, observation of the patient treatment and care areas revealed the State Agency complaint contact information was also not posted in those areas. On 5/08/24 at 9:30 AM, the Administrative Assistant (AA) said she could not locate the State Agency poster and was not sure why it was not in the lobby. On 5/08/24 at 11:30 AM the Facility Administrator (FA) looked in the lobby for the State Agency poster and acknowledged the State Agency Poster was not in the lobby. She stated the facility just decorated the lobby and it must have been removed and not replaced.”

    Rule V0470. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 505 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 39943 Based on record review and interview the facility failed to ensure patients had reached their target weight/estimated dry weight (EDW) during treatment and failed to implement a corrective action plan when the EDW was not achieved for 2 of 7 sampled patients (#1 and #7). Findings: On 5/09/24 while completing a review of patient #1’s medical record, it was noted that the physician prescribed EDW was 94.5 kilogram (kg). The patient was prescribed three treatments a week and the prescribed treatment time was three hours and thirty minutes. The staff failed to identify that patient #1 had not achieved the prescribed EDW on seven of nine treatments and failed to give a reason why the EDW was not attained. Patient #1 did not reach their EDW goal on the following dates: 4/19/24- post wt. 95.0 kg., 4/24/24-post wt. 95.2 kg., 4/26/24-post wt. 95.0 kg., 4/29/24- post wt. 95.2 kg., 5/02/23- post wt. 95.5 kg., 5/06/24-99.5 kg., and 5/08/24- post wt. 95.0 kg.. On 5/09/24, while completing a review of patient #7’s medical record, it was noted that the physician prescribed EDW was 74 kg.. The patient was prescribed three treatments a week and the prescribed treatment time was three hours and forty five minutes. Review of the treatment flow sheets from 4/18/24 to 5/07/24 revealed that patient #7 did not achieve the prescribed EDW on five of nine treatments. Pt. #7 did not achieve the prescribed EDW goal on the following dates: 4/18/24-post wt. 74.6 kg.,4/27/24-post wt. 74.8 kg., 4/30/24-post wt 74.7 kg., 5/04/24-post wt. 74.7 kg., 5/07 24-post wt. 75.3 kg.. Further record review for patients #1 and #7 revealed that there was no evidence, after each treatment, that staff identified the patients had not achieved their respective EDWs nor had they implemented a plan such as scheduling an extra treatment, increased treatment time or ensuring that the dialysis machines’ settings and ultrafiltration rates were correct, to ensure that the prescribed EDW was attained. There was no evidence on the treatment flow sheets that staff had offered an extra treatment so patients #1 and #7 could achieve the doctor prescribed dry weight. On 5/09/24 at 5:10 PM, the Facility Administrator (FA) stated that staff should have addressed the fact that the EDW was not achieved. The FA was unable to explain why #1 and #7 did not have more fluid removed during the dialysis treatment. On 5/10/24 at 6:00 PM the Manager of Clinical Services and the Facility Administrator stated that the IDT (Interdisciplinary Team) met weekly and reviewed and discussed patient charts. One of the areas reviewed is fluid and blood pressure management. Both the FA and MCS acknowledged that #1 and #7 had not been discussed in the IDT meetings regarding not meeting their EDW.”

    Rule V0543. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Dec 16, 2024Complaint inspectionNo deficiencies cited
May 9, 2024Standard inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Apr 3, 2017.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 24 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 4 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 3 of 5 in CMS’s survey of in-center hemodialysis patients (33 interviews, Oct 18, 2024 to Jul 11, 2025): 80% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 53 of 5

How does it compare nearby?

  • Of the 33 dialysis facilities CMS lists in Orange County, 32 have a star rating from CMS: 1 rated 4 of 5, 5 rated 3 of 5, 14 rated 2 of 5, 12 rated 1 of 5.
  • CMS rates this one 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.