Renal CARE Group - Clermont
A dialysis facility in Clermont, Florida 34715
312 Mowhawk Rd, Clermont, Florida 34715. (352) 243-1200.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 1of 5 CMS’s star rating
- Not rated patient survey rating
- 1 deficiency cited in the last three years
- 16 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on May 23, 2024: a standard inspection.
1 deficiency cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
1 deficiency in 1 month of the last 36. Last cited May 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
May 23, 2024: standard inspection1 deficiency
-
Achieve Adequate Clearance
The inspectors’ words, 1,474 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 49777 Based on record review, policy review and interview the facility failed to follow the prescribed blood flow rate (BFR) for 3 patients, Patient #2, Patient #5, and Patient #13, and failed to follow the prescribed dialysate flow rate (DFR) for 1 patient, Patient #7, of 10 in center hemodialysis patients reviewed. Findings Include: Record review of Patient #2’s dialysis treatment orders, in effect 4/12/2024, revealed Patient #2 was prescribed a blood flow rate of 450. Record review of patient #2’s dialysis treatment record, dated 5/10/2024, revealed Patient #2’s blood flow rate was set at 400 seven times during his dialysis treatment on 5/10/2024. Record review of patient #2’s dialysis treatment record for 5/10/2024 failed to reveal documentation that justified or explained why Patient #2’s blood flow rate had deviated from his prescribed blood flow rate. Record review of patient #2’s dialysis treatment record, dated 5/15/2024, revealed Patient #2’s blood flow rate was set at 400 seven times throughout his dialysis treatment on 5/15/2024. Record review of patient #2’s dialysis treatment record failed to reveal documentation that justified or explained why Patient #2’s blood flow rate had deviated from his prescribed blood flow rate. Record review of Patient #5’s dialysis treatment orders, in effect 3/29/2024, revealed Patient #5 was prescribed a blood flow rate of 450. Record review of Patient #5’s dialysis treatment record, dated 5/06/2024, revealed Patient #5’s blood flow rate was set at 400 eight times during his dialysis treatment on 5/16/2024. Record review of patient #5’s dialysis treatment record for 5/06/2024 failed to reveal documentation that justified or explained why Patient #5’s blood flow rate had deviated from his prescribed blood flow rate. Record review of Patient #5’s dialysis treatment record, dated 5/08/2024, revealed Patient #5’s blood flow rate was set at 400 nine times throughout his dialysis treatment on 5/08/2024. Record review of Patient #5’s dialysis treatment record failed to reveal documentation that justified or explained why Patient #5’s blood flow rate had deviated from his prescribed blood flow rate. Record review of Patient #5’s dialysis treatment record, dated 5/15/2024, revealed Patient #5’s blood flow rate was set at 400 eight times throughout his dialysis treatment on 5/15/2024. Record review of Patient #5’s dialysis treatment record failed to reveal documentation that justified or explained why Patient #5’s blood flow rate had deviated from his prescribed blood flow rate Record review of Patient #5’s dialysis treatment record, dated 5/17/2024, revealed Patient #5’s blood flow rate was set at 400 two times and 350 five times throughout his dialysis treatment on 5/17/2024. Record review of Patient #5’s dialysis treatment record failed to reveal documentation that justified or explained why Patient #5’s blood flow rate had deviated from his prescribed blood flow rate Record review of Patient #13’s dialysis treatment orders, in effect 4/23/2024, revealed Patient #13 was prescribed a blood flow rate of 200. Record review of Patient #13’s dialysis treatment record, dated 4/23/2024, revealed Patient #13’s blood flow rate was set at 350 six times throughout his dialysis treatment on 4/23/2024. Record review of Patient #13’s dialysis treatment record failed to reveal documentation that justified or explained why Patient #13’s blood flow rate had deviated from his prescribed blood flow rate Record review of Patient #13’s dialysis treatment orders, in effect 4/25/2024, revealed Patient #13 was prescribed a blood flow rate of 400. Record review of Patient #13’s dialysis treatment record, dated 4/25/2024, revealed Patient #13’s blood flow rate was set at 350 three times and 250 one time throughout his dialysis treatment on 4/25/2024. Record review of Patient #13’s dialysis treatment record failed to reveal documentation that justified or explained why Patient #13’s blood flow rate had deviated from his prescribed blood flow rate Record review of Patient #13’s dialysis treatment record, dated 5/8/2024, revealed Patient #13’s blood flow rate was set at 300 five times throughout his dialysis treatment on 5/8/2024. Record review of Patient #13’s dialysis treatment record failed to reveal documentation that justified or explained why Patient #13’s blood flow rate had deviated from his prescribed blood flow rate During an interview on 5/22/2024 beginning at 1:38 PM, Staff B [Registered Nurse] confirmed the blood flow rate for Patient #2 was set at 400 during treatments on 5/10/20204 and 5/15/2024. Staff B also stated, “A deviation from a patient’s prescribed blood flow rate or dialysate flow rate should always be justified with documentation in the clinical record.” During an interview on 5/22/2024 beginning at 1:38 PM, Staff B [Registered Nurse] confirmed the blood flow rate for Patient #5 was set at 350 during treatments on 5/6/2024, 5/8/2024, 5/15/2024, and 5/17/2024. Staff B also stated, “ A deviation from a patient’s prescribed blood flow rate or dialysate flow rate should always be justified with documentation in the clinical record.” During an interview on 5/22/2024 beginning at 1:38 PM, Staff B [Registered Nurse] confirmed the blood flow rate for Patient #13 was set at 350 during treatments on 4/23/2024 and 4/25/2024 and set at 300 during treatments on 5/8/2024. Staff B also stated, “ A deviation from a patient’s prescribed blood flow rate or dialysate flow rate should always be justified with documentation in the clinical record.” Record review of the facility policy titled “Unable to Achieved Prescribed Blood Flow Rate”, published 11/1/2021, showed the policy read “Achieving prescribed BFR is a critical parameter in achieving adequate treatment Kt/V [clearance time / volume]. Staff, patient and/or care partner will recognize and report to the nurse in charge the inability to achieve prescribed blood flow rate. Notify the physician/extender if unable to achieve prescribed blood flow rate. Document in patient’s treatment record what action taken to address the inadequate blood flow rate and if unable to resolve. The nurse shall document any physician orders.” Record review of Patient #7’s Hemodialysis order, dated 3/29//2024, revealed Patient #7’s prescribed dialysate flow rate was 500. Record review of Patient #1’s dialysis treatment record, dated 5/6/2024, revealed Patient #7’s dialysate flow rate was set at 800 eight times during her treatment on 5/6/2024. Record review of Patient #7’s dialysis treatment record, dated 5/8/2024, revealed Patient #7’s prescribed dialysate flow rate was 500. Record review of Patient #1’s dialysis treatment record, dated 5/6/2024, revealed Patient #7’s dialysate flow rate was set at 800 six times during her treatment on 5/8/2024. Record review of Patient #7’s dialysis treatment record, dated 5/10/2024, revealed Patient #7’s prescribed dialysate flow rate was 500. Record review of Patient #1’s dialysis treatment record, dated 5/10/2024, revealed Patient #7’s dialysate flow rate was set at 800 seven times during her treatment on 5/10/2024. Record review of Patient #7’s dialysis treatment record, dated 5/13/2024, revealed Patient #7’s prescribed dialysate flow rate was 500. Record review of Patient #1’s dialysis treatment record, dated 5/13/2024, revealed Patient #7’s dialysate flow rate was set at 800 eight times during her treatment on 5/13/2024. Record review of Patient #7’s dialysis treatment record, dated 5/15/2024, revealed Patient #7’s prescribed dialysate flow rate was 500. Record review of Patient #1’s dialysis treatment record, dated 5/15/2024, revealed Patient #7’s dialysate flow rate was set at 800 five times during her treatment on 5/15/2024. Record review of Patient #7’s dialysis treatment record, dated 5/17/2024, revealed Patient #7’s prescribed dialysate flow rate was 500. Record review of Patient #1’s dialysis treatment record, dated 5/17/2024, revealed Patient #7’s dialysate flow rate was set at 800 nine times during her treatment on 5/17/2024. Record review of Patient #7’s dialysis treatment records failed to reveal documentation that justified or explained why Patient #7’s dialysate flow rate had deviated from his prescribed dialysate flow rate. During an interview on 5/22/2024 beginning at 1:38 PM, Staff B [Registered Nurse] confirmed the dialysate flow rate for patients #2 was set at 800 during treatments on 5/8/24, 5/10/24, 5/13/24, 5/15/24, and 5/17/24. Staff B also stated, “ A deviation from a patient’s prescribed blood flow rate or dialysate flow rate should always be justified with documentation in the clinical record.” Record review of the facility policy titled “Unable to Achieved Prescribed Blood Flow Rate”, published 11/1/2021, showed the policy read “Achieving prescribed BFR is a critical parameter in achieving adequate treatment Kt/V [clearance time / volume]. Staff, patient and/or care partner will recognize and report to the nurse in charge the inability to achieve prescribed blood flow rate. Notify the physician/extender if unable to achieve prescribed blood flow rate. Document in patient’s treatment record what action taken to address the inadequate blood flow rate and if unable to resolve. The nurse shall document any physician orders.””
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| May 23, 2024 | Standard inspection | 1 deficiency cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jan 3, 2002.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and a shift starting at 5 p.m. or later.
- Doesn’t offer home hemodialysis training.
- 16 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, worse than expected; readmissions to hospital, worse than expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, worse than expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 1 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 13 dialysis facilities CMS lists in Lake County, 12 have a star rating from CMS: 5 rated 3 of 5, 3 rated 2 of 5, 4 rated 1 of 5.
- CMS rates this one 1 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing