Davita Boulder Dialysis Center
A dialysis facility in Boulder, Colorado 80304
2880 Folsom St Ste 110, Boulder, Colorado 80304. (303) 440-5600.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 14, 2026.
- 4of 5 CMS’s star rating
- Not rated patient survey rating
- 5 deficiencies cited in the last three years (needs attention)
- 14 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean4
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
- Condition-level deficiency
- For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.
What did inspectors find?
The last inspection on record was on Jun 25, 2025: a standard inspection.
5 deficiencies cited in the last three years, 2 of them at condition level, the most serious.
2 deficiencies at condition level, the more serious of CMS’s two levels
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
When those deficiencies happened
5 deficiencies in 1 month of the last 36. Last cited Jun 2025. Most serious: Condition-level. The last 3 years, to Oct 19, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
Jun 25, 2025: standard inspection5 deficiencies
-
Cfc - Infection Control
The inspectors’ words, 108 words
“CFC-INFECTION CONTROL CFR(s): 494.30 This Condition is not met as evidenced by: 45020 Based on the manner and degree of the standard level deficiencies referenced to the Condition, it was determined the Condition of Participation §494.30 Infection Control was out of compliance. V113 - Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. Based on observations, interviews, and document reviews, the facility failed to ensure staff performed hand hygiene between each patient or station in five of ten observations conducted of staff activities on the dialysis treatment floor.”
-
Cfc - Physical Environment
The inspectors’ words, 100 words
“CFC-PHYSICAL ENVIRONMENT CFR(s): 494.60 This Condition is not met as evidenced by: 45020 Based on the manner and degree of the standard level deficiencies referenced to the Condition, it was determined the Condition of Participation §494.60 Physical Environment was out of compliance. V407 - Patients must be in view of staff during hemodialysis treatment to ensure patient safety, (video surveillance will not meet this requirement). Based on interviews and document reviews, patient care staff failed to document if hemodialysis patients’ access sites were visualized during their hemodialysis treatments in three of four medical records reviewed. (Patients #1, #2, and #4)”
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 722 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 45020 Based on observations, interviews, and document reviews, the facility failed to ensure staff performed hand hygiene between each patient or station in five of ten observations conducted of staff activities on the dialysis treatment floor. Findings include: Facility policy: The Infection Control for Dialysis Facilities policy read, the purpose of this policy is to minimize the spread of infections or blood borne pathogens in the dialysis facility environment. All teammates, physicians and non-physicians will perform hand hygiene prior to gloving and immediately after removal of gloves. Disposable gloves will be worn when caring for the patient or touching the patient’s equipment at the dialysis station. Gloves should be changed after touching one patient or their dialysis delivery system and before arriving to care for another patient or touching another patient’s dialysis delivery system. 1. The facility failed to ensure staff performed hand hygiene between each patient, workstation, or task when gloves were put on and removed. A. Observations i. On 6/23/25 at 7:53 a.m., an observation was conducted on the dialysis treatment floor. Observations revealed patient care technician (PCT) #1 did not perform hand hygiene prior to putting on gloves. PCT #1 touched the dialysis machine at station #5, where the patient was receiving treatment. PCT #1 then removed their gloves and did not perform hand hygiene. PCT #1 further walked to the patient at station #3 and touched the patient’s blanket with an ungloved hand. PCT #1 then walked to the nurses station without performing hand hygiene. ii. On 6/23/25 at 7:55 a.m. observations of PCT #1 revealed hand hygiene was not performed prior to putting on gloves. PCT #1 touched the dialysis machine at station #10, where a patient was receiving treatment. PCT #1 removed their gloves and did not perform hand hygiene. iii. On 6/25/25 at 7:08 a.m., observations of PCT #1 revealed hand hygiene was not performed prior to putting on gloves. PCT #1 touched the dialysis machine at station #11, where a patient was receiving treatment. PCT #1 removed their gloves and did not perform hand hygiene. iv. On 6/25/25 at 10:09 a.m., observations of medical doctor (MD) #2 revealed hand hygiene was not performed and gloves were not put on prior to touching a patient at station #4. MD #2 proceeded to touch the patient receiving treatment at station #5 without performing hand hygiene or wearing gloves. v. On 6/25/25 at 10:40 a.m., MD #2 was observed at patient station #6. MD #2 touched the patient without wearing gloves, and hand hygiene was not performed before or after. These observations were in contrast to the Infection Control for Dialysis Facilities policy which stated, to minimize the spread of infections or blood borne pathogens, hand hygiene should have been performed prior to gloving and after the removal of gloves. Gloves were to be worn when patient care was performed. B. Interviews i. On 6/25/25 at 12:24 p.m., an interview was conducted with PCT #3. PCT #3 stated hand hygiene was to be performed before gloves were put on and after gloves were removed. PCT #3 stated gloves were to be worn when the patient or dialysis equipment was touched. PCT #3 stated gloves were worn to minimize the risk of infection which could cause death. ii. On 6/25/25 at 12:48 p.m., an interview was conducted with registered nurse (RN) #4. RN #4 stated hand hygiene was expected to be completed before gloves were put on and taken off. RN #4 stated it was important to wear gloves for patient care, and to perform hand hygiene according to facility policy, to minimize the risk of infection and cross contamination between patients. iii. On 6/25/25 an interview was conducted with MD #2. MD #2 stated hand hygiene performed between patients could be improved. MD #2 stated they performed hand hygiene before the treatment floor was entered and exited. MD #2 stated hand hygiene was important because there was a risk for infection to be transferred between patients. MD #2 stated dialysis patients were at a higher risk for infection because most were immunocompromised (impaired immune system).”
-
Pe - Hemodialysis Patients In View During Treatments
The inspectors’ words, 553 words
“PE-HD PTS IN VIEW DURING TREATMENTS CFR(s): 494.60(c)(4) Patients must be in view of staff during hemodialysis treatment to ensure patient safety, (video surveillance will not meet this requirement). This Standard is not met as evidenced by: 45020 Based on interviews and document reviews, patient care staff failed to document if hemodialysis patients’ access sites were visualized during their hemodialysis treatments in three of four medical records reviewed. (Patients #1, #2, and #4) Findings include: Facility policy: The Pre-Intra-Post Treatment Collection, Monitoring and Nursing Assessment policy read, during intradialytic (the period during hemodialysis) treatment, treatment monitoring will be at least every 30 minutes, including vital signs. At a minimum, Registered Nurses (RNs) or Patient Care Technicians (PCTs) obtain and document the following: blood pressure, heart or pulse rate, blood and dialysate flows, arterial and venous pressures, fluid removal and/or replacement, vascular access visible and line connections intact. The vascular access site, blood line connections and the patient’s face should be visible throughout the dialysis treatment. All findings, interventions and patient response will be documented in the patient’s medical record. 1. The facility failed to ensure patients were monitored during their dialysis treatments according to facility policy. Specifically, staff did not visualize patients’ access sites every 30 minutes. A. Document Review i. Review of medical records revealed access site checks were not documented as performed during intradialytic treatment. a. Review of Patient #1’s treatment sheet, dated 6/20/25, revealed the patient’s access site was not visualized and documented every 30 minutes. The patient’s treatment started at 5:57 a.m., and ended at 9:40 a.m. There was no documentation of access site visualization between 8:32 a.m. and 9:32 a.m. b. Review of Patient #2’s treatment sheet, dated 6/20/25, revealed the patient’s access site was not visualized and documented every 30 minutes. The patient’s treatment started at 2:50 p.m., and ended at 5:34 p.m. There was no documentation of access site visualization between 3:04 p.m. and 4:04 p.m. Similar findings were discovered during Patient #2’s treatments on 6/18/25, 6/16/25, 6/13/25 and 6/9/25. c. Review of Patient #4’s treatment sheet, dated 6/11/25, revealed the patient’s access site was not visualized and documented every 30 minutes. The patient’s treatment started at 7:26 a.m., and ended at 10:24 a.m. There was no documentation of access site visualization after 9:03 a.m. This was in contrast to the Pre-Intra-Post Treatment Collection, Monitoring and Nursing Assessment policy, which stated patient access sites should have been visualized and documented every 30 minutes. B. Interviews i. On 6/25/25 at 12:24 p.m., an interview was conducted with PCT #3. PCT #3 stated patients’ access sites were to be visualized and documented every 30 minutes during treatment. PCT #3 stated it was important to visualize patient access sites to ensure the lines to the machine were intact and the access site was not bleeding. PCT #3 also stated there was a risk of death if access sites bled. ii. On 6/25/25 at 12:48 p.m., an interview was conducted with RN #4. RN #4 stated vital signs, including visualization of the patient’s access site was to be performed and documented every 30 minutes during treatment. RN #4 stated if the patient’s access was not visualized every 30 minutes during treatment, there was a risk the patient could bleed out if the needle became dislodged from the patient’s access site.”
-
Dialysis Access Type & Maintenance
The inspectors’ words, 538 words
“PA-DIALYSIS ACCESS TYPE & MAINTENANCE CFR(s): 494.80(a)(8) The patient’s comprehensive assessment must include, but is not limited to, the following: (8) Evaluation of dialysis access type and maintenance (for example, arteriovenous fistulas, arteriovenous grafts and peritoneal catheters). This Standard is not met as evidenced by: 45020 Based on observations and interviews, the facility failed to ensure staff assessed arteriovenous (AV) fistulas (surgically created dialysis access sites) prior to inserting dialysis access needles into the access sites. This failure was identified in two of five patients observed undergoing initiation of dialysis treatment. Findings include: Facility policies: The Arteriovenous Fistula (AVF) and Arteriovenous Graft (AVG) Vascular Access Care policy read, the purpose of this policy is to reduce the risk of infection in the patient, to reduce trauma to the fistula or graft while minimizing blood loss and to maximize the lifetime of each access. Inspection of the AVF or AVG access includes the following: Presence/absence of thrill (a vibration which can be felt) and/or bruit (a loud, rushing sound caused by blood flow moving through the surgical dialysis access). 1. The facility failed to ensure AV fistulas were assessed for a bruit before dialysis access needles were inserted into the access sites. A. Observations i. On 6/23/25 at 10:49 a.m., an observation was conducted at patient dialysis station #10. Patient care technician (PCT) #5 was observed as they inserted needles into an AVF. PCT #5 did not assess the AVF for a bruit with a stethoscope. Both needles were inserted, secured in place with tape, and treatment was started. ii. On 6/25/25 at 10:47 a.m., an observation was conducted at patient dialysis station #14. PCT #5 was observed as they inserted needles into an AVF. PCT #5 did not assess the AVF for a bruit with a stethoscope. Both needles were inserted, secured in place with tape, and treatment was started. This was in contrast to the AVF and AVG Vascular Access Care policy which stated, inspection of the access included the presence of a bruit. B. Interviews i. On 6/25/25 at 12:24 p.m., an interview was conducted with PCT #3. PCT #3 stated a patient’s access was to be auscultated (listened to) with a stethoscope for a bruit and felt with their hand for a thrill, before needles were inserted to ensure the access was functional. PCT #3 stated if there was an absence of a bruit or thrill, they would immediately notify the nurse. PCT #3 stated there was a risk the patient’s access could be clotted, and if a needle were to be inserted, the clot could dislodge to the patient’s heart or lungs, which could cause chest pain or shortness of breath. ii. On 6/25/25 at 12:48 p.m., an interview was conducted with registered nurse (RN) #4. RN #4 stated a stethoscope was to be used to listen for the bruit, as well as felt with the staff member’s hand before the needles were inserted. RN #4 stated there was a risk of a clot within the patient’s access which could cause damage to the AVF. RN #4 stated if the access was clotted or damaged, the patient would not be able to receive their hemodialysis treatment, and they would be transferred to the hospital.”
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jun 25, 2025 | Standard inspection | 5 deficiencies cited |
| Jun 25, 2025 | Standard inspection | No deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Oct 1, 1990.
- Run for profit.
- Cited at For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. in the last three years: it didn’t meet a whole condition of Medicare’s rules for dialysis facilities.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and a shift starting at 5 p.m. or later.
- Doesn’t offer peritoneal dialysis and home hemodialysis training.
- 14 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 4 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, better than expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 4 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 5 dialysis facilities CMS lists in Boulder County, 5 have a star rating from CMS: 4 rated 4 of 5, 1 rated 3 of 5.
- CMS rates this one 4 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 19, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 19, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 14, 2026 and checked Oct 19, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 19, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.