032646-Fmc-Glendale Town Center

A dialysis facility in Glendale, Arizona 85302

4407 West Peoria Ave, Glendale, Arizona 85302. (623) 934-9091.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 4 deficiencies in 1 month of the last 36. Last cited Jan 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jan 28, 2025: a standard inspection.

4 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

4 deficiencies in 1 month of the last 36. Last cited Jan 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

4 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jan 28, 2025: standard inspection4 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 279 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 44268 Based on document review, observation, and interview, it was determined that the facility failed to ensure: Staff performed hand hygiene when moving from one patient station to another, wear gloves on both hands when touching the patient machine, and before and after direct contact with a patient. Findings include: The policy titled “Hand Hygiene” revealed: “...Before and after direct contact with patients ...Immediately after removing gloves ...After contact with inanimate objects near the patient ....” Observation on 01/27/2025 revealed Employee #23 preparing to silence an alarm at station #22 with one glove fully on their right hand, however no glove on their left hand. Observation on 01/27/2025 revealed Employee #23 preparing to silence an alarm at station #21 with one glove fully on their right hand, however no glove on their left hand. Observation on 01/27/2025 at 11:44 am revealed Employee #23 giving a pen to the patient in station #8 with bare hands, then Employee #23 walked over to the glove station and donned a pair of gloves without performing hand hygiene and reset an alarm at station #6. Observation on 01/27/2025 at 12:11 am revealed Employee #23 donned a glove only covering the fingers on their right hand to address an alarm at chair #21. Employee #1 confirmed on 01/28/2025 that Employee #23 did not perform hand hygiene after touching the patients’ machines or touching the patient as required per facility policies and procedures.”

    Rule V0113. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 262 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 44268 Based on document review and interview, it was determined that the facility failed to demonstrate compliance with machine and ancillary equipment preventative maintenance which has the potential risk of damaged and/or non-calibrated equipment being used to provide treatments to dialysis patients. Findings include: A policy titled “Priming an Optiflux Single Use E-Beam Dialyzer”, revealed “...Preform the Pressure Holding Test on all 2008 machines ...If using a FRESENIUS dialysis machine, it is mandatory that the AUTOMATIC TESTING be performed at this time ...Included in this test is the PRESSURE HOLDING TEST, which verifies the integrity of the volumetric balancing system specific to the Fresenius dialysis machine ...If the AUTOMATIC TESTING FAILS, repeat the test ...If the cause of the failure cannot be corrected, or if it fails subsequent tests, the machine SHOULD NOT BE USED ....” Observation on 01/27/2025 revealed a machine that failed the automatic test. Employee #16 then performed the test a second time which failed again. Employee #16 then performed the test a third time. The machine passed the test, and then employee #16 proceeded to use the machine. Employee #1 confirmed in an interview on 01/27/2025 that Employee #16 did not follow policies and procedures to take the machine off the floor and not use it for patient care.”

    Rule V0403. Standard-level.

  • Appropriateness Of Dialysis Rx

    The inspectors’ words, 533 words

    “PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 44268 Based on a review of facility policy, medical records, and staff interviews, it was determined that the facility failed to ensure that staff followed the attending physician’s prescribed hemodialysis (HD) order for blood flow rate (BFR) setting for each individual patient. Failure to follow physician orders and not reporting abnormalities poses the potential risk of inadequate dialysis, decreased clearances, and hospitalizations. Findings include: The facility policy titled “Patient Assessment and Monitoring” requires: “...Check machine settings and measurements: Check prescribed blood flow is being achieved or reason is documented in the medical record if unable to meet prescribed blood flow....” Patient #1 A treatment sheet dated 07/30/2024 revealed that a blood flow rate was prescribed at 400ml/min. At 09:28 the blood flow was set to 450ml/min, at 10:25 it was set to 300ml/min, at 11:00 it was set to 350ml/min, then set to 300ml/min at 13:21, with no documentation alerting the RN. Patient #2 A treatment sheet dated 01/17/2025 revealed that a blood flow rate of 500ml/min was prescribed. At 06:50, the blood flow rate was set to 450ml/min, with no documentation alerting the RN. A treatment sheet dated 01/20/2025 revealed that a blood flow rate of 500ml/min was prescribed. At 07:45, the blood flow rate was set to 450ml/min, with no documentation alerting the RN. A treatment sheet dated 01/22/2025 revealed that a blood flow rate of 500ml/min was prescribed. At 08:24, the blood flow rate was set to 400ml/min, with no documentation alerting the RN. A treatment sheet dated 01/24/2025 revealed that a blood flow rate of 500ml/min was prescribed. At 06:56, the blood flow rate was set to 400ml/min, with no documentation alerting the RN. A treatment sheet dated 01/17/2025 revealed that a blood flow rate of 500ml/min was prescribed. At 09:26, the blood flow rate was set to 450ml/min, with no documentation alerting the RN. Patient #3 A treatment sheet dated 06/21/2024 revealed that a blood flow rate of 400ml/min was prescribed. At 17:51, the blood flow was set to 450ml/min, but no documentation alerted the RN. Patient #4 A treatment sheet dated 01/15/2025 revealed that a blood flow rate of 450ml/min was prescribed. At 08:52, the blood flow was set to 400ml/min, with no documentation alerting the RN. A treatment sheet dated 01/17/2025 revealed that a blood flow rate of 450ml/min was prescribed. At 08:49, the blood flow rate was set to 400ml/min, with no documentation alerting the RN. Patient #5 A treatment sheet dated 06/27/2024 revealed that a blood flow rate of 300ml/min was prescribed. At 16:26, the blood flow rate was set to 400ml/min, at 17:30 the BFR was set to 300ml/min, with no documentation alerting the RN. A treatment sheet dated 08/15/2024 revealed that a blood flow rate of 400ml/min was prescribed. At 17:55, the blood flow rate was set to 450ml/min, with no documentation alerting the RN. Employee #1 confirmed during an interview on 01/28/2025, that this practice does not follow facility policy and procedures or physician orders.”

    Rule V0503. Standard-level.

  • Assess B/P & Fluid Management Needs

    The inspectors’ words, 471 words

    “PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 44268 Based on a review of facility policy, medical records and staff interviews, it was determined that the facility failed to require clinical staff to notify the nurse and provide a documented intervention for (4) out of (5) patients reviewed when the patient’s blood pressure (BP) and/or heart rate (HR) were out of range per the facility policy, which poses the potential risk of cardiovascular compromise and hospitalization. Findings include: The facility policy titled “Patient Assessment and Monitoring....” published on May 1, 2023, revealed:” ...Report to the nurse: Systolic blood pressure greater than 180 mm/Hg, Diastolic blood pressure greater than 100 mm/Hg, Blood Pressure less than or equal to 100 mm/Hg systolic...Heart rates that have dropped below 60 or risen above 100 ...Report to the nurse any significant findings....” A facility document titled “2024 AZ Hemodialysis Standing Orders” revealed, “...Intra HD for a significant drop in systolic BP >40mm/Hg ...Notify nurse....” Facility documents titled, “...Treatment Sheets....” revealed: Patient # 1 06/27/2024 revealed: 11:41 HR 103 12:15 HR 101 07/30/2024 revealed: 11:25 HR 102 13:00 HR 104 08/01/2024 revealed: 09:30 HR 103 10:20 HR 111 12:21 HR 109 13:34 HR 144 08/06/2024 revealed: 09:26 HR 107 11:00 HR 120 12:41 HR 102 13:01 HR 105 08/08/2024 revealed: 10:41 HR 117 08/13/2024 revealed: Pre-treatment HR 54 10:00 HR 54 10:23 HR 53 10:46 HR 57 13:02 BP 186/78 The facility administrator was unable to provide documentation of the RN being made aware of vital signs out of range and/or a change in vital signs. Patient #2 01/15/2025 revealed: 09:21 BP 83/54 The facility administrator was unable to provide documentation of the RN being made aware of vital signs out of range. Patient #4 01/15/2025 revealed: 08:52 HR 59 09:04 HR 52 09:23 HR 103 01/17/2025 revealed: Pre-treatment Standing BP 198/76 Pre-treatment Sitting BP 186/83 08:02 BP 203/73 01/20/2025 revealed: Pre-treatment Standing BP 202/81 Pre-treatment Sitting BP 207/98 07:37 BP 182/80 07:42 BP 194/68 08:03 HR 105 09:02 HR 102 09:21 HR 104 10:38 HR 114 01/24/2025 revealed: 07:48 BP 217/93 08:22 BP 214/67 08:42 BP 196/69 10:02 HR 55 10:44 HR 49 10:48 HR 56 01/27/2025 revealed: Pre-treatment Standing BP 201/88 Pre-treatment Sitting BP 224/96 09:03 HR 114 09:22 HR 110 09:44 HR 103 10:43 HR 101 The facility administrator was unable to provide documentation of the RN being made aware of vital signs out of range. Patient #5 07/23/2024 revealed: Pre-treatment HR 59 17:29 HR 56 17:47 HR 57 18:02 HR 58 Employee #1 confirmed during an interview on 01/28/2025 that no documentation of RN notification and/or intervention for out-of-range vitals was available as required per facility policy.”

    Rule V0504. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jan 28, 2025Standard inspection4 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Aug 29, 2016.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 25 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, worse than expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 2 of 5 in CMS’s survey of in-center hemodialysis patients (38 interviews, Oct 18, 2024 to Jul 11, 2025): 56% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 52 of 5

How does it compare nearby?

  • Of the 70 dialysis facilities CMS lists in Maricopa County, 68 have a star rating from CMS: 1 rated 5 of 5, 10 rated 4 of 5, 35 rated 3 of 5, 18 rated 2 of 5, 4 rated 1 of 5.
  • CMS rates this one 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.