Davita Arrowhead Lakes Dialysis Center
A dialysis facility in Glendale, Arizona 85308
20325 N 51st Ave Ste 186 Bldg 11, Glendale, Arizona 85308. (623) 533-6521.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- 2of 5 patient survey rating
- 4 deficiencies cited in the last three years
- 24 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jun 13, 2024: a standard inspection.
4 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 1 month of the last 36. Last cited Jun 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jun 13, 2024: standard inspection4 deficiencies
-
Cartridge Filters - Config And Monitoring
The inspectors’ words, 411 words
“CARTRIDGE FILTERS-CONFIG & MONITORING CFR(s): 494.40(a) 5.2.3 Cartridge filters: config and monitoring The cartridge is contained within an opaque filter housing with seals to separate the feed and product water streams. When the maximum [pressure drop] ?P recommended by the filter manufacturer is reached, the cartridge should be replaced according to the manufacturer ’ s instructions. 6.2.3 Cartridge filters Cartridge filters should be monitored on a periodic .... basis for a [pressure drop] ?P across the filter [that] can be used to determine when the filter is retaining particulate matter to the point that the filter will no longer allow the required water flow without an excessive reduction in pressure at the outlet of the filter. A marked decrease in ?P without a corresponding decrease in flow rate may indicate a loss of filter integrity. Follow the manufacturer ’ s recommendations concerning when to replace cartridge filters. Replacement of the cartridge will usually be indicated by an increase in ?P to some specified value. A log sheet should be developed to record the pressure drop measurements. This Standard is not met as evidenced by: 45999 Based on a review of facility policy, daily water treatment logs, and staff interview, the Department determined that the facility failed to ensure staff notify the facility administrator (FA) and/or biomed technician (BMT) and appropriate action was taken when the prefilter pressure test result was not within the acceptable limits specified on the daily water treatment log for two (2) of three (3) months reviewed. Failure to maintain water logs per facility policy poses the potential risk of harm to patients and hospitalization if the water system were to malfunction. Findings include: Daily water treatment logs revealed noted issues with the pressure of the prefilter and documented staff notification to BioMed on the following dates: April 19, 2024 April 23, 2024 April 30, 2024 May 5, 2024 May 7, 2024 May 8, 2024 May 9, 2024 Observation of the water room on June 11, 2024 revealed multiple leaks coming from the booster pump, the RO system, and the booster pump to the loop for the treatment floor. A policy was requested, but none was provided. Employee #3 confirmed in an interview conducted on June 11, 2024, that appropriate action was not taken based on continued prefilter pressure test result outside of acceptable limits and multiple leaks in the water. Employee #3 further confirmed that not ensuring appropriate action was taken fails to align with facility policy.”
-
Pe - Safe, Functional, Comfortable Environment
The inspectors’ words, 249 words
“PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 51021 Based on review of facility policy, observation, and staff interview, the Department determined that the facility failed to ensure medications, supplies, and equipment have not expired. Failure to ensure that medication, supplies and equipment have not expired has the potential risk of using expired supplies and equipment for patients which could lower the efficacy of medication and/or could expose patients to supplies with decreased sterility; thus increasing their risk for infection. Furthermore, expired emergency supplies found inside of emergency carts could delay emergency treatment. On 06/10/2024, tour of the facility resulted with the following expired medical supplies: 1 (one) Vacuette NH Trace Elements Sodium Heparin test tube; expired 4/10/2024 2 (two) Serim Guardian Test Strips Bottles; expired 03/31/2024 2 (two) BD Precision Glide Needles 22g x1; expired 01/31/2023 181(one hundred and eighty one) BD Precision Needles 21g x1; expired 08/31/2023 5 (five) Cobas PCR Media uni Swab Packets; expired 04/30/2024 12 (twelve) Greiner Tubes For Solution Swab Sample Collection,Transportation & Storage. Saline 0.85% Solution 3.0ml; expired 05/2024 65 (sixty-five) BD 1ml Insulin Syringe U-100 Slip Tip With BD Precision Glide Needles; expired 04/30/2024 During an interview conducted on June 11, 2024, Employee #3 confirmed the expired supplies had not been discarded in accordance with manufacturer instructions, expiration dates or facility policy.”
-
Pe-Fire Safety-Life Safety Code
The inspectors’ words, 286 words
“PE-FIRE SAFETY-LIFE SAFETY CODE CFR(s): 494.60(e)(1) (1) Except as provided in paragraph (d)(2) of this section, dialysis facilities that do not provide one or more exits to the outside at grade level from the patient treatment area level must comply with provisions of the Life Safety Code (NFPA 101 and its Tentative Interim Amendments TIA 12-1, TIA 12-2, TIA 12-3, and TIA 12-4) applicable to Ambulatory Health Care Occupancies, regardless of the number of patients served. This Standard is not met as evidenced by: 50568 Based on observation and staff interview, the Department determined that the facility failed to ensure that a sprinkler system inspection had occurred in the past 12 months. The lack of annual inspection poses the potential risk that patients and staff would not be protected in the event of a fire if safety controls were to malfunction. Findings include: The facility policy titled “FACILITY EMERGENCY MANAGEMENT PLAN” requires: “ ...Fire Safety Preparedness 1. FA, or designee, is responsible to: a. Maintain a fire safety preparedness program to prevent or minimize the likelihood of a fire that may result in death, injury, or property damage in accordance with CMS and OSHA regulations and National Fire Protection Association (NFPA) and applicable local and state life safety code requirements ....” Observation during a tour on June 10, 2024, revealed the facility had a sprinkler system present. Documentation of a sprinkler system inspection conducted within the past 12 months was requested. No sprinkler system documentation for the past 12 months was provided. During an interview conducted on June 11, 2024, Employee #3 confirmed that a sprinkler system is present at the facility and no documentation for an inspection performed in the past 12 months was available.”
-
Assess B/P & Fluid Management Needs
The inspectors’ words, 1,952 words
“PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 45999 Based on a review of facility policy, medical records, and staff interviews, it was determined that the facility failed to require clinical staff to: 1. It was determined that the facility failed to require clinical staff to notify the nurse and the nurse provided a documented intervention for 4 out of 4 patients reviewed when the patient’s blood pressure (BP) and/or heart rate (HR) was out of range, per the facility policy, which poses the potential risk of cardiovascular compromise and hospitalization. 2. It was determined the facility failed to ensure that vital signs were monitored every 30 minutes while receiving dialysis by a personnel member for 6 (six) out of 8 (eight) patients reviewed, patients #1, # 4, #5, #6, #7 and #8. Failure to ensure patients are monitored by a personnel member every 30 minutes while on dialysis can result in a patient having an undetected adverse event. Findings include: 1. Facility policy titled “PRE-INTRA-POST TREATMENT DATA COLLECTION, MONITORING, AND NURSING ASSESSMENT” requires “...Vital signs and treatment monitoring ...the following are considered abnormal findings and should be reported to the licensed nurse and documented in the patient’s medical record...Intradialytic: Systolic greater than 180mm/Hg or less than 90mm/Hg ...Diastolic greater than or equal to 100mm/Hg or less than 50mm/Hg...Heart or Pulse Rate Pre/Intra/Post: Less than 60 beats per minute or greater than 100 beats per minute...”. Standing patient orders require provider notification with decrease of 20mm/Hg in Blood Pressure. A medical record review of 8 patient’s treatment sheets revealed all (7/8) patients had multiple occurrences, of blood pressure out of range without documentation of the licensed nurse being notified. Patient #1 May 25, 2024 15:50 BP: 145/52 (included to show severity of change) 16:20 BP: 85/50 No notification or intervention documented for 16:20 BP for systolic reading less than 90mm/Hg and change of 20mm/Hg change. May 28, 2024 16:56 BP: 101/45 (included to show severity of change) 17:25 BP: 73/46 17:51 BP: 149/63 (included to show severity of previous change) No notification or intervention documented for 17:25 BP for systolic reading less than 90mm/Hg, diastolic reading less than 50mm/Hg and/or change of 20mm/Hg change. May 30, 2024 15:37 BP: 166/63 (included to show severity of change) 15:56 BP: 118/90 17:16 BP: 117/79 (included to show severity of change) 17:36 BP: 94/53 No notification or intervention documented for 15:56 BP with change of 20mm/Hg. No notification or intervention documented for 17:36 BP with change of 20mm/Hg. June 1, 2024 14:32 BP: 155/73 (included to show severity of change) 14:42 BP: 104/86 15:42 HR: 109 17:22 HR: 47 No notification or intervention documented for 14:42 BP with change of 20mm/Hg. No notification or intervention documented for 15:42 HR greater than 100 bpm. No notification or intervention documented for 17:22 HR less than 60 bpm. June 4, 2024 14:38 BP: 221/194 (included to show severity of change) 14:52 BP: 145/58 15:28 HR:114 No notification or intervention documented for 14:52 BP with change of 20mm/Hg. No notification or intervention documented for 15:28 HR greater than 100 bpm. June 8, 2024 14:00 HR:59 14:29 BP: 151/79 HR:59 (BP included to show severity in change) 15:06 BP: 111/55 17:04 HR:59 17:21 HR:58 17:31 HR:54 No notification or intervention documented for 14:00 HR less than 60 bpm. No notification or intervention documented for 14:29 HR less than 60 bpm. No notification or intervention documented for 15:06 BP with change of 20mm/Hg. No notification or intervention documented for 17:04 HR less than 60 bpm. No notification or intervention documented for 17:21 HR less than 60 bpm. No notification or intervention documented for 17:31 HR less than 60 bpm. Patient #2 June 6, 2024 10:31 BP: 160/128 11:11 BP: 158/103 11:51 BP: 154/108 12:11 BP: 170/120 12:15 BP: 151/109 12:31 BP: 149/111 12:51 BP: 154/111 13:11 BP: 154/111 No notification or intervention documented for 10:31 BP with diastolic reading greater than or equal to 100mm/Hg. No notification or intervention documented for 11:11 BP with diastolic reading greater than or equal to 100mm/Hg. No notification or intervention documented for 11:51 BP with diastolic reading greater than or equal to 100mm/Hg. No notification or intervention documented for 12:11 BP with diastolic reading greater than or equal to 100mm/Hg. No notification or intervention documented for 12:15 BP with diastolic reading greater than or equal to 100mm/Hg. No notification or intervention documented for 12:31 BP with diastolic reading greater than or equal to 100mm/Hg. No notification or intervention documented for 12:51 BP with diastolic reading greater than or equal to 100mm/Hg. No notification or intervention documented for 13:11 BP with diastolic reading greater than or equal to 100mm/Hg. Patient #3 April 30, 2024 08:50 BP: 135/80 (included to show severity of change) 09:10 BP: 115/68 No notification or intervention documented for 09:10 BP with change of 20mm/Hg. Patient #4 May 28, 2024 14:36 HR: 55 No notification or intervention documented for 14:36 HR less than 60 bpm. May 30, 2024 14:37 HR:53 No notification or intervention documented for 14:37 HR less than 60 bpm. June 1, 2024 14:24 HR: 52 15:03 HR: 55 17:52 BP:100/21 No notification or intervention documented for 14:24 HR less than 60 bpm. No notification or intervention documented for 15:03 HR less than 60 bpm. No notification or intervention documented for 17:52 BP with diastolic reading less than 50mm/Hg. June 4, 2024 10:13 HR: 51 10:33 HR: 55 10:54 HR: 54 11:14 BP: 138/101 No notification or intervention documented for 10:13 HR less than 60 bpm. No notification or intervention documented for 10:33 HR less than 60 bpm. No notification or intervention documented for 10:54 HR less than 60 bpm. No notification or intervention documented for 11:14 BP with diastolic reading greater than 100mm/Hg. June 6, 2024 10:08 HR:51 10:49 HR:53 11:29 HR:55 12:09 HR:53 No notification or intervention documented for 10:08 HR less than 60 bpm. No notification or intervention documented for 10:49 HR Less than 60 bpm. No notification or intervention documented for 11:29 HR less than 60 bpm. No notification or intervention documented for 12:09 HR less than 60 bpm. June 8, 2024 10:29 HR:53 12:02 BP:125/101 No notification or intervention documented for 10:29 HR less than 60 bpm. No notification or intervention documented for 12:02 BP with diastolic reading greater than 100m/Hg. Patient #5 June 3, 2024 12:02 BP: 131/102 No notification or intervention documented for 12:02 BP with diastolic reading greater than 100m/Hg. Patient #6 May 16, 2024 17:05 HR:101 No notification or intervention documented for 17:05 HR greater than 100 bpm. May 21, 2024 15:29 HR:107 16:12 HR:106 16:59 HR:107 17:10 HR:106 No notification or intervention documented for 15:29 HR greater than 100 bpm. No notification or intervention documented for 16:12 HR greater than 100 bpm. No notification or intervention documented for 16:59 HR greater than 100 bpm. No notification or intervention documented for 17:10 HR greater than 100 bpm. May 23, 2024 15:09 HR: 102 No notification or intervention documented for 15:09 HR greater than 100 bpm. Patient #7 February 2, 2024 12:04 BP:213/144 HR:120 No notification or intervention documented for 12:04 BP with systolic reading greater than 180mm/Hg, diastolic reading greater than 100mm/Hg, and/or 12:04 HR greater than 100 bpm. Patient #8 July 27, 2023 10:59 HR: 129 13:23 BP:149/101 HR 104 No notification or intervention documented for 10:59 HR greater than 60 bpm. No notification or intervention documented for 13:23 BP with diastolic reading greater than 100mm/Hg and/or 13:23 HR greater than 100 bpm. August 1, 2023 12:13 BP: 153/106 No notification or intervention documented for 12:13 BP with diastolic reading greater than 100mm/Hg. August 15, 2023 11:58 BP: 159/93 (included to show severity of change) 12:20 BP:122/67 12:40 BP:146/83 (included to show severity of change) 13:00 BP:119/68 13:20 BP:131/72 (included to show severity of change) 13:38 BP:102/67 15:34 HR:117 No notification or intervention documented for 12:20 BP with change greater than 20mm/Hg. No notification or intervention documented for 13:00 BP with change greater than 20mm/Hg. No notification or intervention documented for 13:38 BP with change greater than 20mm/Hg. No notification or intervention documented for 15:34 HR greater than 100 bpm. Employee #3 confirmed during an interview on June 11, 2024 that no notification or intervention documentation was available when requested of RNs being notified of vital signs out of range. Employee #3 further confirmed that lack of documentation did not align with facility policies and procedures. Findings include: 2. Facility policy titled, “...Pre-Intra-Post-Treatment Data Collection, Monitoring, and Nursing Assessment....” revised April 2021 revealed: “...Intradialytic Data Collection/Assessment...Vital Signs and Treatment Monitoring...For non-nocturnal treatments is completed at least every thirty (30) minutes....” Post Treatment....” sheets revealed: Patient #1 May 28, 2024 15:21 BP: 142/65 (included to show previous assessment) 16:23 BP: 109/52 Length of time between 15:21 and 16:23 assessments is greater than 30 minutes. June 4, 2024 15:28 BP: 145/76 (included to show previous assessment) 16:00 BP: 102/83 Length of time between 15:28 and 16:00 assessments is greater than 30 minutes. June 8, 2024 14:29 BP: 151/79 (included to show previous assessment) 15:06 BP: 111/55 15:59 BP: 111/53 16:39 BP: 133/64 Length of time between 14:29 and 15:06 assessments is greater than 30 minutes. Length of time between 15:06 and 15:59 assessments is greater than 30 minutes. Length of time between 15:59 and 16:39 assessments is greater than 30 minutes. Patient #4 May 22, 2024 17:24 BP: 136/87 (included to show previous assessment) 17:58 BP: 108/68 Length of time between 17:24 and 17:58 assessments is greater than 30 minutes. May 24, 2024 18:01 BP: 99/66 (included to show previous assessment) 18:43 BP: 117/77 Length of time between 18:01 and 18:43 assessments is greater than 30 minutes. June 3, 2024 16:10 BP: 119/76 (included tos how previous assessment) 16:52 BP: 110/67 17:30 BP: 100/63 18:00 BP: 109/64 (included to sow previous assessment) 18:43 BP: 110/69 Length of time between 16:10 and 16:52 assessments is greater than 30 minutes. Length of time between 16:52 and 17:30 assessments is greater than 30 minutes. Length of time between 18:00 and 18:43 assessments is greater than 30 minutes. Patient #5 May 29, 2024 12:12 BP: 155/83 (included to show previous assessment) 12:49 BP: 149/81 Length of time between 12:12 and 12:49 assessments is greater than 30 minutes. June 3, 2024 11:00 BP: 132/70 (included to show previous assessment) 11:32 BP: 139/79 Length of time between 11:00 and 11:32 assessments is greater than 30 minutes. June 5, 2024 10:51 BP: 159/79 (included to show previous assessment) 12:47 BP: 167/78 12:48 BP: 162/73 (included to show previous assessment) 13:25 BP: 142/78 Length of time between 10:51 and 12:47 assessments is greater than 30 minutes. Length of time between 12:48 and 13:25 assessments is greater than 30 minutes. Patient # 6 May 21, 2024 15:29 BP: 126/73 (included to show previous assessment) 16:12 BP: 127/67 Length of time between 15:29 and 16:12 assessments is greater than 30 minutes. May 23, 2024 15:59 BP: 137/73 (included to show previous assessment) 16:33 BP: 143/74 Length of time between 15:59 and 16:33 assessments is greater than 30 minutes. Patient # 7 March 6, 2024 10:34 BP: 186/137 (included to show previous assessment) 11:14 BP: 135/107 Length of time between 10:34 and 11:14 assessments is greater than 30 minutes. Patient #8 August 15, 2023 13:38 BP: 102/67 (included to show previous assessment) 14:09 BP: 134/73 Length of time between 13:38 and 14:09 assments is greater than 30 minutes. During an interview conducted on June 11, 2024, Employee #3 verified that intradialytic vital signs were not monitored every 30 minutes while receiving dialysis services in accordance with facility policies.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jun 13, 2024 | Standard inspection | 4 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jun 18, 2004.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
- Doesn’t offer a shift starting at 5 p.m. or later.
- 24 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
- In CMS’s survey, patients rate its staff 2 of 5.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, better than expected; patients on a kidney transplant waitlist, as expected.
- Patients rate it 2 of 5 in CMS’s survey of in-center hemodialysis patients (38 interviews, Oct 18, 2024 to Jul 11, 2025): 60% rated the facility 9 or 10 out of 10.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | 2 of 5 |
How does it compare nearby?
- Of the 70 dialysis facilities CMS lists in Maricopa County, 68 have a star rating from CMS: 1 rated 5 of 5, 10 rated 4 of 5, 35 rated 3 of 5, 18 rated 2 of 5, 4 rated 1 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing