Hearth Record

Davita Independence County Dialysis

A dialysis facility in Batesville, Arkansas 72501

1700 Harrison St Ste F, Batesville, Arkansas 72501. (870) 307-0828.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited Oct 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Oct 9, 2024: a standard inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited Oct 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Oct 9, 2024: standard inspection6 deficiencies
  • Environment: Secure And Restricted

    The inspectors’ words, 183 words

    “ENVIRONMENT-SECURE & RESTRICTED CFR(s): 494.40(a) 8 Environment: secure & restricted The water purification and storage system should be located in a secure area that is readily accessible to authorized users. The location should be chosen with a view to minimizing the length and complexity of the distribution system. Access to the purification system should be restricted to those individuals responsible for monitoring and maintenance of the system. This Standard is not met as evidenced by: 37145 Based on observation and interview, the facility failed to ensure one of one Water Room doors were secured to prevent entry of unauthorized person(s). This failed practice failed to ensure the integrity of the treated water and mixed bicarbonate for patient use was protected. The failed practice had the likelihood to affect all 39 patients on census. The findings were: A. Observation on 10/09/24 at 12:30 PM, showed the double doors to the water room were standing wide open and accessible to unauthorized person(s). B. During an interview on 10/09/24 at 12:30 PM, Certified Clinical Hemodialysis Technician (CCHT) #1 confirmed the doors should be shut and locked.”

    Rule V0184. Standard-level.

  • Pe - Building - Constructed/Maintained To Ensure Safety

    The inspectors’ words, 317 words

    “PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 37145 Based on observation and interview, the facility failed to ensure that the integrity of all physical surfaces were intact, clean, and free from damage. The failed practice promoted the spread of infection and had the likelihood to affect all 39 in-center hemodialysis patients on census. The findings were: A. On 10/07/24 from 1:00 PM through 1:45 PM, the following observations were made on tour of the facility: 1) The water room showed: a) There was a buildup of dirt and grime on the floor drain close to the booster pump and M 130 monitoring system. b) The acid tank had a buildup of white residue on the plastic base. A white residue was on the hoses and pipes near the acid tank. c) The sink by the bicarb tank and the drainpipe underneath the sink had a buildup of white residue. d) By bicarb tank 1 there was a purple stain and a buildup of white residue on the floor. 2) The Storage room showed: a) There was a box of biohazard trash bags and hospital towels stored on the floor. b) The painted wooden shelves holding supplies had multiple areas of peeling paint. 3) The door to the biomed office had multiple paint scrapes and stains and a window shelf had chipping paint and a green stain. 4) The treatment room showed: a) Ddirty sink 1 had dirt and grime buildup and a white residue on the fixtures. b) Clean sink 2 had a buildup of white residue. c) The pack cart had a buildup of white residue. B. During an interview on 10/07/24 at 1:45 PM, the findings in A were verified with the Facility Administrator.”

    Rule V0402. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 310 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 37145 Based on observation, policy review and interview, the facility failed to ensure blood pressure (BP) cuffs were maintained in that there was a build-up of threads in the hook portion of the Velcro which did not allow for effective cleaning and disinfection and failed to ensure an open vial of Tubersol was discarded within Manufacturer recommended guidelines after opened. The failed practice promoted the spread of infection from cross contamination. The failed practice had the likelihood to affect all 39 in-center hemodialysis patients on census and staff. The findings were: A. Review of the facility policy titled, “Infection Control for Dialysis Facilities,” revised April/2023 showed, “At the end of each treatment, the dialysis station will be cleaned and disinfected. Surfaces to disinfect include but are not necessarily limited to: all surfaces in contact with the patient or their belongings (dialysis chair, tray tables, blood pressure cuffs) and frequently contacted by healthcare personnel (control panel, top, front and sides of dialysis machine, touchscreens and countertops).” B. Review of the Tubersol package insert showed, “Storage, A vial of Tubersol which has been entered and in use for 30 days should be discarded.” C. On 10/07/24 at 1:20 PM, a vial of Tubersol dated 08/13/24 was observed in the medication refrigerator. The Administrator stated, “It needs to be tossed.” D. On 10/09/24 from 9:00 AM to 11:00 AM shift change observations showed multiple fibers in the blood pressure cuffs at stations 1, 3, 4, and 12. E. During an interview on 10/09/24 at 9:15 AM, the facility Administrator confirmed the findings in B-D.”

    Rule V0403. Standard-level.

  • Assess Current Health Status Inc Comorbids

    The inspectors’ words, 338 words

    “PA-ASSESS CURRENT HEALTH STATUS/COMORBIDS CFR(s): 494.80(a)(1) The patient’s comprehensive assessment must include, but is not limited to, the following: (1) Evaluation of current health status and medical condition, including co-morbid conditions. This Standard is not met as evidenced by: 37145 Based on clinical review, and interview, it was determined a Registered Nurse (RN) failed to assess or intervene for one (#2) of five (#1-#5) patients reviewed with a pulse rate outside of parameters. The failed practice did not ensure the physician was aware of the patient’s health status to determine the course of treatment and had the likelihood to affect all 39 in center hemodialysis patients on census. Findings follow: A. Review of the facility Pre-Intra-Post treatment data collection, monitoring and nursing assessment with revision date of April 2024, showed, “Abnormal findings or findings outside of any patient specific physician ordered parameters will be reported to the licensed nurse immediately (refer to abnormal findings section in this policy). The licensed nurse will use his/her clinical judgement based on individual patient needs to determine if any clinical interventions are necessary. The licensed nurse notifies the physician (or NPP if applicable) as needed in the patient status. Heart Rate Pre/Intra/Post: Less than 60 beats per minute or greater than 100 beats per minute and/or an irregular heartbeat.” B. Patient 2: 1) Review of six TFS (treatment flow sheets) dated 09/09/24 -10/04/24, showed no evidence the RN assessed the patient’s pulse rate, provided treatment, and/or notified Physician of findings. Heart Rate examples: a) 09/16/24-Predialytic - 57, Intradialytic - 44, 45, 48, 49, 50, 51, 52, Post-dialytic - 52 b) 09/20/24- Predialytic - 51, Intradialytic - 44, 45, 50, 52, 53 c) 10/02/24- Intradialytic - 54, 56 d) 10/04/24- Predialytic - 70, Intradialytic - 38, 41, 43, 45, 111, Post-dialytic - 55 2) There was no evidence that an RN assessment had been completed or physician notification of the out of heart rates. 3) In an interview with the Facility Administrator on 10/09/24 at 1:15 PM, the findings in A-B were confirmed.”

    Rule V0502. Standard-level.

  • Assess B/P & Fluid Management Needs

    The inspectors’ words, 927 words

    “PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 37145 Based on clinical record review, policy review, and interview, it was determined the Registered Nurse (RN) failed to assess, treat, and/or notify Physician of the blood pressure (BP) for five of five (Patient 1-#5) in center hemodialysis patients reviewed. The failed practice placed patients at risk for complications related to un-managed blood pressure. The failed practice had the likelihood to affect all 39 in-center hemodialysis patients. The findings were: A. Review of the facility Pre-Intra-Post treatment data collection, monitoring and nursing assessment with revision date of April 2024, showed, “Abnormal findings or findings outside of any patient specific physician ordered parameters will be reported to the licensed nurse immediately (refer to abnormal findings section in this policy). The licensed nurse will use his/her clinical judgement based on individual patient needs to determine if any clinical interventions are necessary. The licensed nurse notifies the physician (or NPP if applicable) as needed in the patient status. Blood Pressure: Pre-dialysis: systolic greater than 180 mm/Hg (millimeters of mercury) or less than 90 mm/Hg. Diastolic greater than or equal to 100 mm/Hg or less than 50 mm/Hg. Blood pressure-Interdialytic: systolic greater than 180 mm/Hg (millimeters of mercury) or less than 90 mm/Hg. Diastolic greater than or equal to 100 mm/Hg or less than 50 mm/Hg. Signs/symptoms of hypotension, restlessness, nausea, vomiting, diaphoretic, excessive yawning. Blood Pressure Post Treatment: Standing systolic BP (blood pressure) greater than 140 mm/Hg or less than 90 mm/Hg. Standing diastolic BP greater than 90 mm/Hg or less than 50 mm/Hg. Sitting BP for patients that cannot stand: Standing systolic BP (blood pressure) greater than 140 mm/Hg or less than 90 mm/Hg. Standing diastolic BP greater than 90 mm/Hg or less than 50 mm/Hg.” B. Patient #1 1) Review of five TFS (treatment flow sheets), five of six treatments, dated 09/27/24 - 10/7/24. a) 09/27/24 - Intradialytic BP 161/68 b) 09/30/24 - Intradialytic BP 145/62 and Post treatment 164/70. c) 10/02/24 - Intradialytic BP 146/56 and Post treatment 151/55. d) 10/04/24 - Intradialytic BP 161/67, 176/71, and Posttreatment 151/55 e) 10/07/24 - Intradialytic BP 183/98 and post treatment 183/98 2) There was no evidence that an RN assessment had been completed or physician notification of the out of range blood pressures. 3) During the interview on 10/09/24 at 1:20 PM, the Facility Administrator confirmed the findings in B. C. Patient #2 1) Review of six TFS, six of six treatments, dated 09/10/24 - 10/03/24. BP Examples: a) 09/09/24 - Intradialytic 96/57, 97/46 b) 09/11/24 - Pretreatment - 150/86, Intradialytic - 81/49, 95/54, 98/55, 96/56, 89/56, Post treatment 112/69. c) 09/16/24 - Pretreatment - 96/51, Intradialytic - 87/43,93/49,93/51,87/45,90/51 Posttreatment 102/53. d) 09/30/24 - Pretreatment - 100/43, Intradialytic - 93/52, 93/35, 87/41, 96/46, Post treatment 134/61. e) 10/02/24 - Pretreatment - 93/49, Intradialytic - 88/41, 87/41, 93/47, 86/50, 96/58, 95/50, Post treatment 138/50. f) 10/04/24 - Pretreatment - 80/56, Intradialytic - 68/37, 82/42, 86/43, 76/57, 85/46, Posttreatment 108/66. 2) There was no evidence that an RN assessment had been completed or physician notification of the out of range blood pressures. 3) During the interview on 10/09/24 at 1:20 PM, the Facility Administrator confirmed the findings in C. D. Patient # 3 1) Review of six TFS, five of six treatments, dated 09/10/24 - 10/03/24. BP Examples: a) 09/10/24 - Pretreatment 146/49, Intradialytic 150/67, 96/64 Post treatment 149/72. b) 09/12/24 - Pretreatment 148/60, Intradialytic 102/55, 173/71 Post treatment 142/68 c) 09/17/24 - Pretreatment 155/74, Intradialytic 85/45, 98/35 Post treatment 129/62 d) 09/24/24 - Pretreatment 170/72, Intradialytic 102/54, Post treatment 142/68 e) 10/01/24 - Pretreatment 132/56, Intradialytic 140/64,104/54 Post treatment 125/59 f) 10/03/24 - Pretreatment 188/68, Intradialytic 192/81,118/56 Post Treatment 160/67 2) There was no evidence that an RN assessment had been completed or physician notification of the out-of-range blood pressures. 3) During the interview on 10/09/24 at 1:20 PM, the Facility Administrator confirmed the findings in D. E. Patient # 4 1) Review of six TFS, six of six treatments, dated 09/23/24 - 10/04/24. BP Examples: a) 09/23/24 - Pretreatment 164/63, Intradialytic 130/59, 168/60 Post treatment 173/73. b) 09/25/24 - Pretreatment 154/58, Intradialytic 141/53, Post treatment 148/55 c) 09/27/24 - Pretreatment 176/68, Intradialytic 171/67, 163/61, Post treatment 148/62 d) 09/30/24 - Pretreatment 148/48, Intradialytic 121/47, Post treatment 145/54. e) 10/02/24 - Pretreatment 186/56, Intradialytic 174/63, Post treatment 185/73 f) 10/04/24 - Pretreatment 138/58, Intradialytic 110/46, 116/46, Post treatment 143/59. 2) There was no evidence that an RN assessment had been completed or physician notification of the out-of-range blood pressures. 3) During the interview on 10/09/24 at 1:20 PM, the Facility Administrator confirmed the findings in E. F. Patient # 5 1) Review of six TFS, six of six treatments, dated 09/23/24 - 10/04/24. BP Examples: a) 09/23/24 - Pretreatment 124/51, Intradialytic 98/40, 103/44, Post treatment 121/55. b) 09/25/24 - Pretreatment 113/52, Intradialytic 64/36, 98/48, 81/56 Post treatment 132/64. c) 09/27/24 - Pretreatment 113/52, Intradialytic 85/50, 57/17, 111/54 Post treatment 136/72. d) 09/30/24 - Intradialytic 128/60, Intradialytic 105/67, 106/34, 114/44 Post treatment 140/74. e) 10/02/24 - Pretreatment 160/67, Intradialytic 91/30, 102/33, 186/52 Post treatment 136/55. f) 10/04/24 - Pretreatment 147/59, Intradialytic 86/51, 87/32, 97/48, 94/54 Post treatment 105/46. 2) There was no evidence that an RN assessment had been completed or physician notification of the out of range blood pressures. 3) During the interview on 10/09/24 at 1:20 PM, the Facility Administrator confirmed the findings in F.”

    Rule V0504. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 936 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 37145 Based on clinical record review, policy review, and interview, it was determined the Interdisciplinary Team (IDT) failed to modify the patient’s plan of care (POC) for five of five (Patient #1-#5) in center hemodialysis patients when the patients’ blood pressure was outside established parameters. The failed practice placed patients at risk for complications related to un-managed blood pressure and fluid volume. The failed practice had the likelihood to affect all 39 in center hemodialysis. The findings were: A. Review of the facility Pre-Intra-Post treatment data collection, monitoring and nursing assessment with revision date of April 2024, showed, “Abnormal findings or findings outside of any patient specific physician ordered parameters will be reported to the licensed nurse immediately (refer to abnormal findings section in this policy). The licensed nurse will use his/her clinical judgement based on individual patient needs to determine if any clinical interventions are necessary. The licensed nurse notifies the physician (or NPP if applicable) as needed in the patient status. Blood Pressure: Pre-dialysis: systolic greater than 180 mm/Hg (millimeters of mercury) or less than 90 mm/Hg. Diastolic greater than or equal to 100 mm/Hg or less than 50 mm/Hg. Blood pressure-Interdialytic: systolic greater than 180 mm/Hg (millimeters of mercury) or less than 90 mm/Hg. Diastolic greater than or equal to 100 mm/Hg or less than 50 mm/Hg. Signs/symptoms of hypotension, restlessness, nausea, vomiting, diaphoretic, excessive yawning. Blood Pressure Post Treatment: Standing systolic BP (blood pressure) greater than 140 mm/Hg or less than 90 mm/Hg. Standing diastolic BP greater than 90 mm/Hg or less than 50 mm/Hg. Sitting BP for patients that cannot stand: Standing systolic BP (blood pressure) greater than 140 mm/Hg or less than 90 mm/Hg. Standing diastolic BP greater than 90 mm/Hg or less than 50 mm/Hg.” B. Patient #1 1) Review of five TFS (treatment flow sheets), five of six treatments, dated 09/27/24 - 10/7/24. a) 09/27/24 - Intradialytic BP 161/68 b) 09/30/24 - Intradialytic BP 145/62 and Post treatment 164/70. c) 10/02/24 - Intradialytic BP 146/56 and Post treatment 151/55. d) 10/04/24 - Intradialytic BP 161/67, 176/71, and Posttreatment 151/55 e) 10/07/24 - Intradialytic BP 183/98 and post treatment 183/98 2) There was no evidence the IDT modified the POC related to the patient’s BPs outside of established parameters. 3) During the interview on 10/09/24 at 1:20 PM, the Facility Administrator confirmed the findings in B. C. Patient #2 1) Review of six TFS, six of six treatments, dated 09/10/24 - 10/03/24. BP Examples: a) 09/09/24 - Intradialytic 96/57, 97/46 b) 09/11/24 - Pretreatment - 150/86, Intradialytic - 81/49, 95/54, 98/55, 96/56, 89/56, Post treatment 112/69. c) 09/16/24 - Pretreatment - 96/51, Intradialytic - 87/43,93/49,93/51,87/45,90/51 Posttreatment 102/53. d) 09/30/24 - Pretreatment - 100/43, Intradialytic - 93/52, 93/35, 87/41, 96/46, Post treatment 134/61. e) 10/02/24 - Pretreatment - 93/49, Intradialytic - 88/41, 87/41, 93/47, 86/50, 96/58, 95/50, Post treatment 138/50. f) 10/04/24 - Pretreatment - 80/56, Intradialytic - 68/37, 82/42, 86/43, 76/57, 85/46, Posttreatment 108/66. 2) There was no evidence the IDT modified the POC related to the patient’s BPs outside of established parameters. 3) During the interview on 10/09/24 at 1:20 PM, the Facility Administrator confirmed the findings in C. D. Patient # 3 1) Review of six TFS, five of six treatments, dated 09/10/24 - 10/03/24. BP Examples: a) 09/10/24 - Pretreatment 146/49, Intradialytic 150/67, 96/64 Post treatment 149/72. b) 09/12/24 - Pretreatment 148/60, Intradialytic 102/55, 173/71 Post treatment 142/68 c) 09/17/24 - Pretreatment 155/74, Intradialytic 85/45, 98/35 Post treatment 129/62 d) 09/24/24 - Pretreatment 170/72, Intradialytic 102/54, Post treatment 142/68 e) 10/01/24 - Pretreatment 132/56, Intradialytic 140/64,104/54 Post treatment 125/59 f) 10/03/24 - Pretreatment 188/68, Intradialytic 192/81,118/56 Post Treatment 160/67 2) There was no evidence the IDT modified the POC related to the patient’s BPs outside of established parameters. 3) During the interview on 10/09/24 at 1:20 PM, the Facility Administrator confirmed the findings in D. E. Patient # 4 1) Review of six TFS, six of six treatments, dated 09/23/24 - 10/04/24. BP Examples: a) 09/23/24 - Pretreatment 164/63, Intradialytic 130/59, 168/60 Post treatment 173/73. b) 09/25/24 - Pretreatment 154/58, Intradialytic 141/53, Post treatment 148/55 c) 09/27/24 - Pretreatment 176/68, Intradialytic 171/67, 163/61, Post treatment 148/62 d) 09/30/24 - Pretreatment 148/48, Intradialytic 121/47, Post treatment 145/54. e) 10/02/24 - Pretreatment 186/56, Intradialytic 174/63, Post treatment 185/73 f) 10/04/24 - Pretreatment 138/58, Intradialytic 110/46, 116/46, Post treatment 143/59. 2) There was no evidence the IDT modified the POC related to the patient’s BPs outside of established parameters. 3) During the interview on 10/09/24 at 1:20 PM, the Facility Administrator confirmed the findings in E. F. Patient # 5 1) Review of six TFS, six of six treatments, dated 09/23/24 - 10/04/24. BP Examples: a) 09/23/24 - Pretreatment 124/51, Intradialytic 98/40, 103/44, Post treatment 121/55. b) 09/25/24 - Pretreatment 113/52, Intradialytic 64/36, 98/48, 81/56 Post treatment 132/64. c) 09/27/24 - Pretreatment 113/52, Intradialytic 85/50, 57/17, 111/54 Post treatment 136/72. d) 09/30/24 - Intradialytic 128/60, Intradialytic 105/67, 106/34, 114/44 Post treatment 140/74. e) 10/02/24 - Pretreatment 160/67, Intradialytic 91/30, 102/33, 186/52 Post treatment 136/55. f) 10/04/24 - Pretreatment 147/59, Intradialytic 86/51, 87/32, 97/48, 94/54 Post treatment 105/46. 2) There was no evidence the IDT modified the POC related to the patient’s BPs outside of established parameters. 3) During the interview on 10/09/24 at 1:20 PM, the Facility Administrator confirmed the findings in F.”

    Rule V0543. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Oct 9, 2024Standard inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Aug 30, 1999.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 12 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • No other dialysis facility CMS lists is in Independence County.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.