Hearth Record

Davita Russellville Dialysis

A dialysis facility in Russellville, Alabama 35653

14897 Hwy 43, Russellville, Alabama 35653. (256) 332-7044.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 8 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jan 25, 2024: a standard inspection.

8 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

8 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

8 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jan 25, 2024: standard inspection8 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 338 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 41624 Based on observations, facility policy, and interview, it was determined the facility failed to ensure staff followed the facility policy for hand hygiene and PPE (personal protective equipment). This affected one of two observations of Discontinuation of Dialysis with Central Venous Catheter (CVC) for an unsampled patient, and had the potential to negatively affect all patients with a CVC that dialyze at this facility. Findings include: Facility Policy: Infection Control for Dialysis Facilities Policy number: 1-05-01 Revision Date: April 2023 Purpose: To minimize the spread of infections or bloodborne pathogens in the dialysis facility environment. Hand Hygiene: 1. All teammates, physicians, and non-physicians will perform hand hygiene (HH): ...c. after contamination with blood or other infectious material, ...g. before touching clean areas such as supplies... ...3. Use of an alcohol-based hand rub may be substituted for handwashing... PPE: ...7. Disposable gloves will be worn when caring for the patient or touching the patient’s equipment at the dialysis station... ...a. Gloves should be changed when: ...ii. When going from a “dirty” area or task to a “clean” area or task... 1. An observation of discontinuation of dialysis with a CVC by Employee Identifier (EI) # 2, Registered Nurse, was conducted at station 7 on 1/24/24 at 11:28 AM for an unsampled patient. During the observation, EI # 2 touched and pulled the garbage can closer to him/her while wearing gloves, then proceeded to place a new clean field under the CVC limbs without changing gloves and performing HH. EI # 2 failed to perform HH and change gloves when going from a dirty area to a clean task per policy. An interview was conducted on 1/25/24 at 2:29 PM with EI # 1, Facility Administrator, who confirmed EI # 2 failed to perform HH per policy.”

    Rule V0113. Standard-level.

  • Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts

    The inspectors’ words, 528 words

    “IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 41624 Based on observations, review of facility policies, and interview, it was determined the staff failed to ensure: 1. Contaminated prime waste was not emptied in a designated clean area. 2. Medications were stored in cabinet(s) or under supervision by the licensed teammate per facility policy. This did affect one of two observations for cleaning and disinfection of the dialysis station, and one random observation of prepared medications for an unsampled patient, and had the potential to negatively affect all 45 patients who dialyzed at the facility. Findings include: Facility Policy: Medication Policy Policy Number: 1-6-01 Revision Date: October 2023 Purpose: To provide guidance for medication management in the facility... Policy: ...11. ...Non-refrigerated medications are to be stored in cabinet(s)... or if not under supervision by the licensed teammate... Facility Policy: Infection Control For Dialysis Facilities Policy Number: 1-05-01 Revision Date: April 2023 Purpose: To minimize the spread of infections or bloodborne pathogens in the dialysis facility environment. ...Disinfection: ...13. At the end of each treatment, the dialysis station will be cleaned and disinfected. ...ii. Priming containers are to be emptied prior to disinfection. Facility Hygiene: 16. Clean areas should be clearly designated...clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. 1. During observations of care on 1/23/24 at 7:56 AM, the surveyor observed two syringes labeled, “Heparin,” on the chair side table top at station 1, which was vacant. The staff failed to store the Heparin in cabinet(s) or under supervision by the licensed teammate as per facility policy. An interview was conducted on 1/23/24 at 8:20 AM with Employee Identifier (EI) # 1, Facility Administrator, who confirmed the heparin syringes were not stored per policy. 2. An observation of cleaning and disinfection of the dialysis station was conducted on 1/23/24 at 2:55 PM with EI # 3, Certified Clinical Hemodialysis Technician (CCHT), at station 6. During the observation, EI # 3 removed the prime bucket from the dialysis machine and emptied the prime waste contents into the designated clean sink. EI # 3 failed to keep the clean area separated from a contaminated area per facility policy. An interview was conducted on 1/25/24 at 2:29 PM with EI # 1 who confirmed facility policy was not followed to keep designated clean and contaminated areas separated.”

    Rule V0117. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 271 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 41624 Based on observations, facility policy and interview, it was determined the facility failed to ensure staff followed the facility policy for cleaning and disinfection of the dialysis station between patients in one of two observations of dialysis station disinfection. This had the potential to affect all 45 patients who dialyzed at this facility. Findings include: Facility Policy Number: 1-05-01 Title: Infection Control for Dialysis Facilities Revision Date: April 2023 Purpose: To minimize the spread of infections or blood borne pathogens in the dialysis facility environment. Disinfection ...13. At the end of each treatment, the dialysis station will be cleaned and disinfected. a. Surfaces to disinfect include but are not necessarily limited to: all surfaces in contact with the patient or their belongings ...dialysis chair, tray tables....and frequently contacted by healthcare personnel ... 14. Non-disposable items are to be disinfected after each patient use... 1. An observation for cleaning and disinfection of the dialysis station was conducted on 1/23/24 at 2:55 PM at station 6 with Employee Identifier (EI) # 3, Certified Clinical Hemodialysis Technician. EI # 3 failed to clean and disinfect the television arms and control knobs. An interview was conducted on 1/25/24 at 2:29 PM with EI # 1, Facility Administrator, who confirmed the dialysis station was not cleaned/disinfected per facility policy.”

    Rule V0122. Standard-level.

  • Frequency - Initial: 30 Days/13 Tx

    The inspectors’ words, 288 words

    “PA-FREQUENCY-INITIAL-30 DAYS/13 TX CFR(s): 494.80(b)(1) An initial comprehensive assessment must be conducted on all new patients (that is, all admissions to a dialysis facility), within the latter of 30 calendar days or 13 hemodialysis sessions beginning with the first dialysis session. This Standard is not met as evidenced by: 41624 Based on review of medical records (MR), facility policy, and interview with facility staff, it was determined the facility failed to ensure the initial Plan of Care (POC) was completed within 30 days or 13 treatments for one of one records reviewed for newly admitted patients. This affected Patient Identifier (PI) # 2 and had the potential to negatively affect all patients newly admitted to this facility. Findings include: Facility Policy: Interdisciplinary Team (IDT) Patient Assessment and Plan Of Care Policy Number: 1-14-01 Revision Date: July 2023 Policy: Plan of Care: 8. The facility’s IDT will develop and implement a written, individualized comprehensive POC that specifies the services necessary... ...10. An initial POC...will be completed on all patients new to dialysis within 30 calendar days (or 13 outpatient dialysis sessions for hemodialysis) beginning with the first outpatient dialysis treatment... 1. PI # 2 was admitted to the facility on 8/10/23 with a diagnosis of ESRD (End Stage Renal Disease). Review of the MR revealed the initial POC was signed and dated by each IDT member on 9/13/23, which was 34 days after admission. The IDT failed to complete and develop the POC for PI # 2 within 30 calendar days of admission. An interview was conducted on 1/25/24 at 2:20 PM with Employee Identifier # 1, Facility Administrator, who confirmed the POC was not developed within 30 calendar days of the first outpatient dialysis treatment per facility policy.”

    Rule V0516. Standard-level.

  • Frequency Reassessment - Unstable - Monthly

    The inspectors’ words, 366 words

    “PA-FREQUENCY REASSESSMENT-UNSTABLE Q MO CFR(s): 494.80(d)(2) In accordance with the standards specified in paragraphs (a)(1) through (a)(13) of this section, a comprehensive reassessment of each patient and a revision of the plan of care must be conducted- At least monthly for unstable patients including, but not limited to, patients with the following: (i) Extended or frequent hospitalizations; (ii) Marked deterioration in health status; (iii) Significant change in psychosocial needs; or (iv) Concurrent poor nutritional status, unmanaged anemia and inadequate dialysis. This Standard is not met as evidenced by: 41624 Based on review of medical records (MR), facility policy and staff interview, it was determined the facility failed to ensure the Interdisciplinary Team (IDT) completed at least monthly re-assessments and care plan updates for Patient Identifier (PI) # 3, one of one unstable MR’s reviewed. This had the potential to negatively affect all patients served by the facility. Findings include: Facility Policy: IDT Patient Assessment and Plan Of Care Policy Number: 1-14-01 Revision Date: July 2023 Policy: Assessment: ...2. The IDT is responsible for providing each patient with an individualized and comprehensive assessment documenting his/her needs. The comprehensive assessment will be used to develop the patient’s treatment plan and expectations for care. ...7. A comprehensive re-assessment of each patient and a revision in the plan of care will be conducted: - At least monthly for unstable patients ... 1. PI # 3 was admitted to the facility on 12/16/2020 with a diagnosis of End Stage Renal Disease. Review of the MR revealed PI # 3 was deemed unstable by the IDT on 7/17/23. Further review of the MR revealed an IDT monthly review/revision of the Plan of Care (POC) was performed 8/23/23 and 9/20/23, in which PI # 3 remained unstable. The next POC review/revision was dated 11/2/23, which was 43 days after the 9/20/23 assessment. There was no documented POC review/revision for the month of October. The POC review/revision was not performed monthly per policy for an unstable patient. An interview was conducted 1/25/24 at 2:14 PM with Employee Identifier # 1, Facility Administrator, who confirmed there was no POC dated for the month of October and facility policy was to perform them at least monthly.”

    Rule V0520. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 973 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 41624 Based on review of medical records (MR), facility policy and interviews with the staff, it was determined the facility failed to ensure post treatment weights greater than one kilogram (kg) from the prescribed target weight were reported to the physician. This deficient practice affected four of five hemodialysis MR’s reviewed and did affect Patient Identifier (PI) # 2, PI # 3, PI # 4, and PI # 5 and had the potential to negatively affect all 45 hemodialysis patients dialyzing at this facility. Findings include: Facility Policy: Pre-Intra-Post Treatment Data Collection, Monitoring and Nursing Assessment Policy Number: 1-03-08 Revision Date: October 2023 Purpose: To obtain and document baseline and ongoing information before, during and after dialysis treatment... Policy: 1. Patient data will be obtained and documented... a. Data collection includes... iv. Patient weight... Intradialytic Data Collection/Assessment ...11. Abnormal findings or findings outside of any patient specific physician ordered parameters will be reported to the licensed nurse immediately (refer to “Abnormal Findings” section in this policy). Post Treatment Data Collection/Assessment 15. The PCT (Patient Care Technician) or licensed nurse will obtain and document basic data on each patient post dialysis and compare to pre-dialysis findings. ...17. Licensed nurse will use their clinical judgement based on individual patient needs to determine if ... notification of physician...is necessary prior to discharge of the patient from the facility. Abnormal Findings Fluid Status: Post-treatment: If patient is above or below 1 kg from the target weight. 1. PI # 2 was admitted to the facility on 8/10/23 with a diagnosis of ESRD (End Stage Renal Disease). Review of the ICHD (In-center Hemodialysis) Prescription with order start date 1/13/24 revealed PI # 2 had a prescribed target weight of 73 kg. Review of the Treatment Details Report (TDR) dated 1/17/24 revealed PI # 2 had a post treatment weight of 75.4 kg, which was 2.4 kg over the prescribed target weight. There was no documentation the physician was notified the post weight was greater than (>) one kg over the target weight. Review of the TDR dated 1/19/24 revealed PI # 2 had a post treatment weight of 75.2 kg, which was 2.2 kg over the prescribed target weight. There was no documentation the physician was notified the post weight was > one kg over the target weight. Review of the TDR dated 1/22/24 revealed PI # 2 had a post treatment weight of 75.0 kg, which was 2.0 kg over the prescribed target weight. There was no documentation the physician was notified the post weight was > one kg over the target weight. An interview was conducted on 1/25/24 at 2:20 PM with Employee Identifier (EI) # 1, Facility Administrator, who confirmed staff failed to follow facility policy and notify the physician for a post treatment weight > one kg above the target weight. 2. PI # 3 was admitted to the facility on 12/16/2020 with a diagnosis of ESRD. Review of the ICHD Prescription with order start date 12/14/23 revealed PI # 3 had a prescribed target weight of 82 kg. Review of the TDR dated 1/8/24 revealed PI # 3 had a post treatment weight of 83.4 kg, which was 1.4 kg over the prescribed target weight. There was no documentation the physician was notified the post weight was > one kg over the target weight. An interview was conducted on 1/25/24 at 2:14 PM with EI # 1 who confirmed staff failed to follow facility policy and notify the physician for a post treatment weight > one kg above the target weight. 3. PI # 4 was admitted to the facility on 5/18/22 with a diagnosis of ESRD. Review of the ICHD Prescription with order start date 1/6/24 revealed PI # 4 had a prescribed target weight of 80.5 kg. Review of the TDR dated 1/8/24 revealed PI # 2 had a post treatment weight of 83.0 kg, which was 2.5 kg over the prescribed target weight. There was no documentation the physician was notified the post weight was > one kg over the target weight. An interview was conducted on 1/25/24 at 2:08 PM with EI # 1 who confirmed staff failed to follow facility policy and notify the physician for a post treatment weight > one kg above the target weight. 4. PI # 5 was admitted to the facility on 10/2/23 with a diagnosis of Acute Kidney Injury. Review of the ICHD Prescription with order start date 12/22/23 revealed PI # 5 had a prescribed target weight of 78.5 kg. Review of the TDR dated 1/10/24 revealed PI # 5 had a post treatment weight of 80.2 kg, which was 1.7 kg over the prescribed target weight. There was no documentation the physician was notified the post weight was > one kg over the target weight. Review of the TDR dated 1/12/24 revealed PI # 5 had a post treatment weight of 80.2 kg, which was 1.7 kg over the prescribed target weight. There was no documentation the physician was notified the post weight was > one kg over the target weight. Review of the TDR dated 1/22/24 revealed PI # 5 had a post treatment weight of 80.2 kg, which was 1.7 kg over the prescribed target weight. There was no documentation the physician was notified the post weight was > one kg over the target weight. An interview was conducted on 1/25/24 at 1:51 PM with EI # 1 who confirmed staff failed to follow facility policy and notify the physician for a post treatment weight > one kg above the target weight.”

    Rule V0543. Standard-level.

  • Achieve Adequate Clearance

    The inspectors’ words, 563 words

    “POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 41624 Based on review of Medical Records (MR), policies and staff interviews, it was determined the facility failed to ensure the staff followed the physician’s orders for Blood Flow Rate (BFR) and Dialysate Flow Rate (DFR). This deficient practice affected two of five in-center hemodialysis (ICHD) records reviewed and did affect Patient Identifer (PI) # 2 and PI # 4, and had the potential to negatively affect all 45 ICHD patients who dialyzed at this facility. Findings include: Facility Policy: Pre-Intra-Post Treatment Data Collection, Monitoring, and Nursing Assessment Policy Number: 1-03-08 Revision Date: 10/2023 Purpose: To obtain and document baseline and ongoing information about the patient before, during, and after the dialysis treatment... Policy: ...3. Patient identity, prescription, and machine settings are verified by teammate prior to initiation of treatment with the exception of BFR which is verified and documented when the ordered rate is obtained after onset of treatment... Intradialytic Data Collection/Assessment: ...9. ...b. At a minimum, obtain and document the following: ...iii. Blood and dialysate flows... ...10. If the dialysis prescription is not being met (including DFR or change to/inability to obtain prescribed BFR) the reason will be documented... 1. PI # 2 was admitted to the facility on 8/10/23 with a diagnosis of ESRD (End Stage Renal Disease). Review of the ICHD (In-center Hemodialysis) Prescription with order start date 12/18/23 revealed PI # 2 had an ordered DFR of 600 ml/min (milliliters per minute). Review of the Treatment Details Report (TDR) dated 1/12/24 revealed the DFR ran at 500 from the beginning of treatment 2:03 PM until the end of treatment 5:30 PM. There was no reason documented why the DFR was 500 and not 600 as ordered. Review of the TDR dated 1/17/24 revealed the DFR ran at 500 from the beginning of treatment 11:02 AM until the end of treatment 2:05 PM. There was no reason documented why the DFR was 500 and not 600 as ordered. Review of the TDR dated 1/22/24 revealed the DFR ran at 500 from the beginning of treatment 1:26 PM until the end of treatment 5:03 PM. There was no reason documented why the DFR was 500 and not 600 as ordered. An interview was conducted on 1/25/24 at 2:20 PM with Employee Identifier (EI) # 1, Facility Administrator (FA), who confirmed the staff failed to follow policy and document why the DFR was not run at the ordered rate. 2. PI # 4 was admitted to the facility on 5/18/22 with a diagnosis of ESRD. Review of the ICHD Prescription with order start date 1/6/24 revealed PI # 4 had a prescribed BFR of 350 ml/min. Review of the TDR dated 1/12/24 revealed the BFR was decreased to 250 at 10:31 AM until the end of treatment at 11:16 AM. There was no reason documented why the BFR was 250 and not 350 as ordered. An interview was conducted on 1/25/24 at 2:08 PM with EI # 1 who confirmed the staff failed to follow policy and document why the BFR was not run at the ordered rate.”

    Rule V0544. Standard-level.

  • Vascular Access - Monitor/Referrals

    The inspectors’ words, 381 words

    “POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 41624 Based on observations, review of facility procedure and interview, it was determined the facility failed to ensure staff performed AVF/AVG (arteriovenous fistula/graft) site preparation per facility procedure in one of two observations conducted for AVF/AVG access and initiation of dialysis for an unsampled patient. This had the potential to negatively affect all patients who dialyze with an AVF/AVG at this facility. Findings include: Facility Procedure Number: 1-04-01E Facility Procedure: AV (Arteriovenous) Fistula or Cannulation with Nipro or Medisystems Safety Fistula Needles (SFN) and Administration of Heparin Loading Dose. Revision Date: October 2022 ...Materials required: 70 % alcohol preps ...Skin antiseptic... Notes: Check for patient sensitivity to preferred antiseptic/skin disinfectant listed in table below. Use Isopropyl Alcohol 70 % as the single skin antiseptic ONLY when the patient has documented allergies to other skin antiseptics. Notes: ...Skin Antiseptic Povidone Iodine...Effective Contact Time 30 seconds, Air Drying Time 2 minutes ...Isopropyl Alcohol 70 %...Effective Contact Time 60 seconds, Air Drying Time 15 seconds Procedure: ...10. While maintain(ing) aseptic technique, prep each planned needle site by applying a 70% alcohol prep pad to each site... 11. While maintaining aseptic technique, cleanse the site by applying skin antiseptic... 1. An observation of care for access of AVF/AVG for initiation of dialysis was conducted on 1/23/24 at 11:35 AM with Employee Identifier (EI) # 3, Certified Clinical Hemodialysis Technician (CCHT), at station 2 for an unsampled patient. Using an alcohol pad, EI # 3 performed antisepsis to each site of the AVF/AVG for five seconds, and after dry time, performed antisepsis with a povidone iodine pad for three seconds to each site. EI # 3 failed to perform antisepsis to each access site for the minimal effective contact time per facility procedure. An interview was conducted on 1/25/24 at 2:29 PM with EI # 1, Facility Administrator, who confirmed staff failed to perform access site antisepsis of the cannulation sites per facility procedure.”

    Rule V0550. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jan 25, 2024Standard inspection8 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Jun 20, 2001.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 10 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • No other dialysis facility CMS lists is in Franklin County.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.