Fkc Shelby
A dialysis facility in Alabaster, Alabama 35007
1010 First Street North, Suite 100, Alabaster, Alabama 35007. (205) 728-6286.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 4 deficiencies cited in the last three years
- 24 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jul 9, 2025: a standard inspection.
4 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jul 9, 2025: standard inspection4 deficiencies
-
Ic - Sanitary Environment
The inspectors’ words, 241 words
“IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 52064 Based on observation, staff interview, and policy review, the facility failed to ensure sharps containers were not stored in the same area as clean equipment that could be used on patients in their care for one of three survey days. This practice can lead to cross contamination of all 64 patients in the facility. Findings include: During observation in the patient treatment room on 07/07/25 at 12:40 PM it was observed a rolling stand with three sharps containers was pushed into the storage area that also had the emergency evacuation container, oxygen concentrators and two rolling manual sphygmomanometers. Interview with Registered Nurse (RN)7 on 07/07/25 at 12:40 PM confirmed the stand with the sharps containers was in the designated “clean” area and was stored beside patient care equipment. RN7 confirmed that sharps containers were not to be stored beside patient care equipment. Review of the facility’s policy titled, “General Cleanliness and Infection Control Guidelines” published 05/05/25, indicated “The purpose of this policy is to provide guidance for FKC staff on preventing the spread of infectious disease and maintaining a clean, safe, and aesthetically pleasant environment for patients, staff, and visitors. All areas must be kept clean and organized.””
-
Ic - Items Taken To Station Disposed/Dedicated Or Disinfected
The inspectors’ words, 360 words
“IC-IF TO STATION=DISP/DEDICATE OR DISINFECT CFR(s): 494.30(a)(1)(i) Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient. -- Nondisposable items that cannot be cleaned and disinfected (e.g., adhesive tape, cloth covered blood pressure cuffs) should be dedicated for use only on a single patient. -- Unused medications (including multiple dose vials containing diluents) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients. This Standard is not met as evidenced by: 52064 Based on observation, staff interview, and policy review, the facility failed to ensure equipment used in patient care was disinfected as per facility policy and stored appropriately for one of the three survey days. Failure to disinfect appropriately has the potential to cause harm to all 64 patients dialyzed in the facility. Findings include: During observation in the patient treatment area on 07/07/25 at 12:35 PM, 27 blue hemostats were noted to be laying on a pad in an area designated as “dirty sink.” Four of 27 blue hemostats were in a closed position. In an area designated as “clean sink” a container marked “dirty clamps” was noted. In an interview with Registered Nurse (RN)7 on 07/07/25 at 12:46 PM, he/she acknowledged the blue hemostats had been disinfected and were laying on the pad to dry and some of the clamps were in a closed position. RN7 confirmed the area was marked “dirty” and the clamps should not be stored for drying in a “dirty” area. RN7 also verified the container marked “dirty clamps” was sitting in an area designated as a “clean sink” counter. Review of the facility’s policy titled, “Cleaning and Disinfecting the Dialysis Station” published 09/05/23, indicated, “Cleaning Clamps: Place used plastic pressure clamps and plastic hemostat clamps in a labeled opaque plastic container filled with a 1:100 bleach solution...Make sure the items are completely submerged, unclamped, and in open position when placed in the solution.””
-
Achieve Adequate Clearance
The inspectors’ words, 592 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 52064 Based on record review, interview, and policy review, the facility failed to follow the individualized dialysis plan (an artificial means of kidney function that removes the waste and excess fluid from the blood by passing through a filter) by following the physician prescription as determined by the medical provider for four of seven sampled in-center dialysis patients (Patient (P)2, P3, P4 and P6). Failure to follow the medical providers’ dialysis prescription had the potential to negatively impact on the effectiveness of the prescribed dialysis treatments for all 64 patients receiving in-center dialysis treatments at this facility. Findings include: 1. Review of P2’s “Treatment Data Sheet” revealed a prescribed Blood Flow Rate (BFR) of 400 milliliters per minute (ml/min), and a Dialysate Flow Rate (DFR) of autoflow 2.0 ml/min or 800 ml/min. Review of two of six flowsheets from 06/25/25 through 07/07/25 indicated the following: a. On 06/27/25 from 9:01 AM until 12:59 PM, the BFR was documented at 400 ml/min and the DFR at 500 ml/min. b. On 07/02/25 from 9:21 AM until 1:21 PM, the BFR was documented at 300 ml/min and the DFR was documented at 600 ml/min. There was no documentation for the change to the prescribed BFR and DFR. 2. Review of P3’s “Treatment Data Sheet” revealed a prescribed BFR of 300 ml/min, and a DFR of 500 ml/min. Review of three of six flowsheets from 06/25/25 through 07/07/25 indicated the following: a. On 06/27/25 from 11:05 AM until 2:55 PM, the BFR was documented at 300 ml/min and the DFR at 600 ml/min. b. On 06/30/25 from 10:49 AM until 2:44 PM, the BFR was documented at 350 ml/min. c. On 07/04/25 from 11:03 AM until 3:28 PM, the BFR was documented at 400 ml/min. There was no documentation for the change to the prescribed BFR and DFR. 3. Review of P4’s “Treatment Data Sheet” revealed a prescribed BFR of 300 ml/min, and a DFR of 300 ml/min. Review of two of six flowsheets from 06/24/25 through 07/05/25 indicated the following: a. On 06/26/25 from 6:39 AM until 10:12 AM, the DFR was documented at 500 ml/min. b. On 06/26/25 from 6:36 AM until 8:34 AM, the DFR was documented at 500 ml/min. There was no documentation for the change to the prescribed DFR. 4. Review of P6’s “Treatment Data Sheet” revealed a prescribed BFR of 350 ml/min, and a DFR of 600 ml/min. Review of two of six flowsheets from 06/24/25 through 07/05/25 indicated the following: a. On 06/26/25 from 11:57 AM until 2:59 PM, the DFR was documented at 500 ml/min. b. On 06/26/25 from 11:49 AM until 2:49 PM, the BFR was documented at 300 ml/min. There was no documentation for the change to the prescribed DFR and BFR. In an interview with the Clinical Manager on 07/09/25 at 10:25 AM, he/she confirmed the above findings, and that staff did not follow the physician’s order for dialysis treatment. Review of facility’s policy titled, “Patient Assessment and Monitoring” published 05/01/23, indicated “...Machine Parameters...Check machine settings and measurements: Check prescribed blood flow is being achieved or reason is documented in medical record if unable to meet prescribed blood flow...Check dialysate flow rate setting is correct, and the prescribed flow is being delivered.””
-
Manage Anemia/H/H Measured Monthly
The inspectors’ words, 360 words
“POC-MANAGE ANEMIA/H/H MEASURED Q MO CFR(s): 494.90(a)(4) The interdisciplinary team must provide the necessary care and services to achieve and sustain the clinically appropriate hemoglobin/hematocrit level. The patient’s hemoglobin/hematocrit must be measured at least monthly. The dialysis facility must conduct an evaluation of the patient’s anemia management needs. This Standard is not met as evidenced by: 52064 Based on record review, staff interview, and review of the facility’s document, the facility failed to initiate the algorithm in a timely manner for one of four sampled patient (Patient (P) 3). Failure to initiate the algorithm when ordered resulted in the further decline in hemoglobin (Hgb) values for one of four patients reviewed. Findings include: Review of medical record for Patient (P)3 revealed the following lab values for P3: 06/18/25- Hgb was 10.3g/dl (grams per deciliter) 06/20/25 - Hgb 9.4g/dl; TSAT (Transferrin Saturation) 8 06/23/25 - Hgb 9.1g/dl 06/30/25 -Hgb 8.2g/dl Record review indicated P3’s goal for Plan of Care is Hgb value 10g/dl-11g/dl and TSAT greater than 20. Review of the Provider rounding notes on 06/20/25 indicated, “Impression & Plan. . .3. Anemia-Mircera and Venofer per protocol´ In an interview conducted with the Clinic Manager on 07/09/25 at 10:25 AM, he/she indicated the algorithm for the Mircera was on hold due to low TSAT value and P3 had to receive 10 doses of Venofer 100 milligrams (mg) given during every dialysis treatment before Mircera was initiated. The Clinic Manager stated the Venofer dose had not been started but would be initiated today (07/09/25). The Clinic Manager acknowledged the order to start the Anemia Management Protocol was given on 06/20/25 and it is now 19 days later. Document titled “Anemia Algorithm Dose Change Assessment” last entry date 07/02/25, indicated, “...Prescribed Medication Summary Mircera (blank) Venofer : New Dose New Frequency 100 mg IVP (Intravenous Push) 3 times per week ...On After Date 06/23/25 Number of Doses: 10 Comments: ESA (Erythropoiten Stimulating Agent) Comment: Do not start Mircera until patient has received 1g (gram) iron sequence per iron algorithm... Venofer Comment: Apparent late response to prior calculated dose change or delay in getting order...100mg IVP 3X Week). Medication: Venofer Order Start Date 07/09/25.””
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jul 9, 2025 | Standard inspection | 4 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Apr 8, 1999.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and a shift starting at 5 p.m. or later.
- Doesn’t offer peritoneal dialysis and home hemodialysis training.
- 24 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 6 dialysis facilities CMS lists in Shelby County, 6 have a star rating from CMS: 1 rated 4 of 5, 5 rated 3 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Fmc Cahaba Valley | 3 |
| Fmc Montevallo | 3 |
| Davita Greystone Dialysis | 3 |
| Fkc Oak Mountain | 4 |
| Davita Imperial Home Dialysis | 3 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.