Hearth Record

Dci Cullman

A dialysis facility in Cullman, Alabama 35055

1734 Eva Road NE, Cullman, Alabama 35055. (256) 734-3055.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 3 deficiencies in 1 month of the last 36. Last cited Sep 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Sep 11, 2025: a standard inspection.

3 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

3 deficiencies in 1 month of the last 36. Last cited Sep 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

3 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Sep 11, 2025: standard inspection3 deficiencies
  • Ic - Sanitary Environment

    The inspectors’ words, 422 words

    “IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 41624 Based on observations, clinic policy and procedures, and interview, it was determined the clinic failed to ensure staff performed antisepsis over cannulation sites per policy. This deficient practice affected two of two observations for Access of (arteriovenous) Fistula or Graft for Initiation of Dialysis, including Patient Identifier (PI) # 11 and PI # 9, and had the potential to affect all patients dialyzing with an AVF/AVG at this clinic. Findings include: Clinic Policy: Vascular Access Disinfectant Policy Procedure Number: 804 Date Issued: 1/24/2024 Policy: ...4. All staff will adhere to contact and drying time per antiseptic. Procedure: Option 1 (preferred): Chlorhexidine (Brand names include ChloraPrep and Prevantics) ...Apply disinfectant by using a gentle, back and forth scrubbing motion for a total of 30 seconds. Allow area to dry completely... Clinic Policy: Cannulation of the AV Graft or established AV Fistula Procedure Number; 802 Date Issued: 5/18/2022 Procedure: ...7. Clean chosen cannulation sites with disinfectant in a circular motion working inward to outward...Allow disinfectant to dry. *NOTE* for disinfectant chlorhexadine, drying time 30 seconds. 1. An observation was conducted on 9/9/25 at 11:05 AM with Employee Identifier (EI) # 4, Certified Clinical Hemodialysis Technician (CCHT), performing access of AVF/AVG for initiation of dialysis at station 9 for PI # 11. EI # 4 cleansed the cannulation sites with a chloraprep swab for five seconds and allowed them to dry for 15 seconds. An interview was conducted on 9/11/25 at 2:00 PM with EI # 1, Nurse Manager, who confirmed the staff failed to follow the clinic policy for antisepsis. 2. An observation was conducted on 9/9/25 at 11:06 AM with EI # 4 performing access of AVF/AVG for initiation of dialysis at station 14 for PI # 9. EI # 4 utilized a Prevantics (chlorhexadine) swab to perform antisepsis over each cannulation site using a circular motion for four seconds over each site. EI # 4 then allowed the sites to dry for two seconds before cannulating (accessing) with the dialysis needles. EI # 4 failed to perform antisepsis for 30 seconds, and wait 30 seconds for the sites to dry before cannulating per clinic policy. An interview was conducted on 9/11/25 at 2:00 PM with EI # 1, who confirmed the CCHT failed to perform antisepsis per policy. 47295”

    Rule V0111. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 515 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 41624 Based on observations, clinic policy and procedure, and staff interview, it was determined the clinic failed to ensure staff cleaned and disinfected the dialysis station between patients per policy. This deficient practice was observed in three of three observations for Cleaning and Disinfection of the Dialysis Station, and had the potential to affect all patients dialyzing at this clinic. Findings include: Clinic Policy: Routine Disinfection in the Hemodialysis Unit Procedure Number: 204 Date Issued: 8/19/2020 Supportive Data: ...Proper cleaning and disinfection of environmental surfaces (including patient chairs or bed surfaces, dialysis equipment surfaces, adjacent tables and work surfaces) must be performed between patient uses to prevent transmission of dangerous pathogens. Procedure: ...3. To clean the dialysis machine, start at the top of the machine. Ensure that all items from top to bottom are cleaned, including but not limited to: IV (intravenous) pole, stethoscope (if left on machine), prime bucket/container, all components of machine (i.e. air detector, heparin pump, blood pump doors, Hansen connector and tubing), blood pressure cuff and tubing, any concentrate containers, bottom, sides, shelf and back of machine. 4...Ensure all components of the chair are cleaned top to bottom including but not limited to...Side tables, remotes/call lights.. 1. An observation was conducted on 9/9/25 at 9:45 AM with Employee Identifier (EI) # 2, Registered Nurse (RN), for cleaning and disinfection of dialysis station 9. EI # 2 failed to disinfect the Hansen connectors, prime waste container, IV pole hooks, and the counters behind the station. An interview was conducted on 9/11/25 at 2:00 PM with EI # 1, Nurse Manager, who confirmed the RN did not follow the policy for cleaning and disinfection of the dialysis station. 2. An observation was conducted on 9/10/25 at 10:27 AM with EI # 3, Certified Clinical Hemodialysis Technician (CCHT), for cleaning and disinfection of dialysis station 6. EI # 3 failed to disinfect the upper portion of the IV pole and hooks, Hansen connectors, sides of the tables, nurse call bell, and the counter behind the station. An interview was conducted on 9/11/25 at 2:00 PM with EI # 1, who confirmed the CCHT did not follow the policy for cleaning and disinfection of the dialysis station. 3. An observation was conducted on 9/10/25 at 10:51 AM with EI # 3 for cleaning and disinfection of dialysis station 5. EI # 3 failed to disinfect the upper portion of the IV pole and hooks, Hansen connectors, the bottom half of the front of the dialysis machine, dialysate hoses, sides of the tables, and the counter behind the station. An interview was conducted on 9/11/25 at 2:00 PM with EI # 1, who confirmed the CCHT did not follow the policy for cleaning and disinfection of the dialysis station. 47295”

    Rule V0122. Standard-level.

  • Ic - Staff Education Re Catheters/Catheter Care

    The inspectors’ words, 810 words

    “IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 41624 Based on observations, clinic policy and procedures, manufacturer’s directions for use (MDFU), and staff interview, it was determined the clinic failed to ensure: 1. Antisepsis was performed per clinic procedure and MDFU in two of two observations of Central Venous Catheter (CVC) Exit Site Care. 2. Disinfection of the CVC connections was performed per clinic procedure and MDFU in two of two observations of Discontinuation of Dialysis with a CVC. This deficient practice affected Patient Identifier (PI) # 1, PI # 7, PI # 10, and PI # 8, and had the potential to affect all patients dialyzing with a CVC at this clinic. Findings include: Clinic Policy: Dressing Change and Site Care for the CVC Using Chlorhexidine Gluconate Securement (CHG) Dressing Procedure Number: 701 Date Issued: 1/30/2018 Procedure: ...6. Clean exit site with disinfectant. Preferred is Chlorhexidine. Allow disinfectant to dry completely... Key Point: If using Chlorhexidine product (Chloroprep, Prevantics, etc.), manufacturer’s recommendations are to start at center of exit site and clean outward in a concentric circular motion, using repeated back and forth strokes.. Clinic Policy: Termination of Treatment with Catheter Procedure Number: 705 Date Issued: 9/21/2022 Procedure: ...18. Clean arterial and venous needle-less connector with an alcohol pad... BD (Becton Dickinson) Chloraprep Single Swabstick MDFU: Directions: ...Use repeated back and forth strokes for 30 seconds. Allow the area to air dry for approximately 30 seconds... PDI (Professional Disposables International) Prevantics MDFU: Directions: ...Apply swab to skin using repeated back and forth strokes for 15 seconds. Allow the prepped area to air dry for 30 seconds. 1. An observation was conducted on 9/9/25 at 10:00 AM with Employee Identifier (EI) # 2, Registered Nurse (RN), performing discontinuation of dialysis with a CVC for PI # 1 at station 2. The CVC connections were disinfected with Prevantics for approximately five seconds. EI # 2 failed to follow the Prevantics MDFU which state to scrub for 15 seconds. An interview was conducted on 9/11/25 at 2:00 PM with EI # 1, Nurse Manager, who confirmed the staff failed to disinfect the CVC connections per the MDFU. 2. An observation was conducted on 9/9/25 at 10:17 AM with EI # 2, RN, performing Discontinuation of Dialysis with CVC for PI # 7 at station 4. EI # 2 scrubbed the CVC arterial connection/hub for three seconds with a Prevantics swab, and immediately applied the sterile port cap. EI # 2 then scrubbed the venous connection/hub for one second utilizing another Prevantics swab and immediately applied the sterile port cap. EI # 2 failed to follow the MDFU to perform a 15 second scrub and allow it to air dry for 30 seconds. An interview was conducted on 9/11/25 at 2:00 PM with EI # 1, who confirmed the RN failed to disinfect the connections/hubs per the MDFU for Prevantics. 3. An observation was conducted on 9/9/25 at 11:39 AM with EI # 2, performing CVC exit site care for PI # 10 at station 1. The CVC exit site was cleansed with Prevantics for five seconds. It was then allowed to dry for ten seconds. EI # 2 failed to follow the Prevantics MDFU which state to scrub for 15 seconds and allow to dry for 30 seconds. An interview was conducted on 9/11/25 at 2:00 PM with EI # 1, who confirmed the staff failed to disinfect the exit site per the MDFU. 4. An observation was conducted on 9/9/25 at 11:47 AM with EI # 2 performing CVC Exit Site Care for PI # 8 at station 16. EI # 2 cleaned the exit site utilizing a Chloraprep swab for five seconds, allowed the site to air dry for 30 seconds, then applied a new dressing. EI # 2 failed to clean the site for 30 seconds before allowing it to air dry. An interview was conducted on 9/11/25 at 2:00 PM, with EI # 1, who confirmed the RN failed to clean the exit site per the MDFU for Chloraprep. 47295”

    Rule V0147. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Sep 11, 2025Standard inspection3 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Jan 4, 1996.
  • Run as a non-profit.
  • No deficiency on record in the last three years.
  • Chain: Dialysis Clinic, Inc.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 16 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Dialysis Clinic, Inc. chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 4 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 54 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 2 dialysis facilities CMS lists in Cullman County, 2 have a star rating from CMS: 1 rated 4 of 5, 1 rated 3 of 5.
  • CMS rates this one 4 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

1 compared
PlaceStar rating
Dci South Cullman3

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.